3
damages that crystallized honey may cause (i.e. damaging the
sealing, honey leakage
).
In case of improper maintenance, the
sealing may be broken. Damages resulting from improper
pump cleaning are not subject to the guarantee
Storing
Once the device operation has terminated, the device must be
cleaned and dried.
Before every season, additional inspection for technical issues
must be performed and in case when any faults are detected,
a service centre must be contacted
PREPARING THE DEVICE FOR OPERATION
NOTE!
PRIOR TO STARTING WORK WITH THE PUMP, IT MUST
BE SUBMERGED INTO THE HONEY !!!
Guidelines :
1. Connect the hose with a terminal and a clamp to the
foreign spigot by means of clamp with a gasket.
2. Prior to pumping, the honey ought to be warmed up to the
temperature of approximately 40°C
The pump hose is not included.
PUMP DESCRIPTION
power 2,2 kW
-
optimum efficiency 1500 L/h at honey temp 30° C
−
Power supply 400V
−
Efficiency from 1500 l/h to 3000 l/h
−
2800 rpm
PUMPS WITH POWER SUPPLY OF 400
V
The pumps with the power supply of 400V has the controller
with the knob “P” right, “L” left and “0” stop
.
Depending on the electrical installation, the engine will rotate
leftwards or rightwards.
Switch ‘P”
-
right or “L”
-left serves for selecting the worm
rotating direction.
The pump is stopped by turning the switch to “0” position (stop)
PRIOR TO PUMPING, CHECK THE ROTATION
DIRECTION.
1-motor
2-control
3-suction spigot
4-pump body
5-pump impeller