Knife spacing is adjusted by two levers, adjustment lever A
and locking lever B
Fig.18.
Fig.18.
3.2 . Heating system
WARNING!!!!
The tank should be filled up with liquid after the unit
has been disconnected from the mains via the filler Fig.
B!
The closed circuit is topped up before start-up with a
quantity of (6 LITRES) in proportion:
5 L. WATER + 1 L. propylene glycol (organic
compound)
IMPORTANT!!!
During operation the level of liquid in the closed circuit must
be checked regularly. If the liquid level falls to the minimum
(see level indicator Fig. A), stop the unit, disconnect it from
the power supply and refill the tank.
After topping up the liquid, switch on the heating of the
knives again. Wait for the reheating of the uncapping
knives. Start the uncapping machine and return to the
uncapping process.
A
Liquid level indicator in closed circuit
B Filler port through which we refill the liquid tank.
3.3. Uncapping
Start heating the knives with the "
START
" button
Fig. 8
.
When the knives have heated up, place the frames in the
previously adjusted sliders
"6" Fig. 15
, start the uncapping
machine with the "
START"
button
Fig. 10
and start the
uncapping process. If the uncapping machine is also
equipped with an extruder, start it with the "
START
" button
Fig. 12.
Check the quality of the uncapped frames and make
adjustments if necessary.
Before adjusting, stop the operation of the uncapping
machine and the heating of the knives ("STOP" button
Fig. 11 and Fig. 9)!
Then switch off the power at the control
box
"3" Fig.15
.
A
B