LYSON PREMIUM PC-03 Скачать руководство пользователя страница 4

2. PC-03 controller

The PC-03 controller operates the uncapping machine and 
the extruder.
The control panel is divided into two parts; the left part 
controls the operation of the extruder, while the right part 
controls the operation of the uncapping machine Fig.2.

After placing the device in a desired place and 

blocking the wheels:
- plug in the device.
- check the level of water in the closed circuit tank
- check if the safety switch on the controller housing

is not depressed (by gently turning it as arrows on the top

of the switch)  Fig3 no.4
- set the main switch to position "1" Fig 1

Power supply unit with the main switch.

230V  socket                                    Main switch

Fig.1

After the above steps, the driver panel will start.

Fig.2

400V or 230V power supply. 
Check the feeder chain work direction before starting

Fig.3

1) Controller unit
2) Chain speed adjustment
4) Safety switch
3) Changing the working direction of the feeder chain
5) Knife angle adjustment

The controller unit buttons (Fig. 2) are used to switch the 
machine on and off and to configure the parameters.
The settings are stored in the controller memory.

Содержание PREMIUM PC-03

Страница 1: ...ne with PC 03 CONTROLLER 230V or 400V Przedsi biorstwo Pszczelarskie Tomasz yso Sp ka z o o Sp ka Komandytowa 34 125 Su kowice ul Rac awicka 162 Polska www lyson com pl email lyson lyson com pl Headqu...

Страница 2: ...ctrical safety 1 2 Operation safety 2 PC 03 controller 2 1 Buttons 2 2 Controller operation 2 3 Error codes 3 Instructions for use 3 1 General rules preparation for use 3 2 Heating system 3 3 Uncappin...

Страница 3: ...heat sources and sharp edges to ensure its good condition 1 2 Operation safety a The device is not intended for use by persons including children with limited physical sensory or mental abilities or b...

Страница 4: ...ler housing is not depressed by gently turning it as arrows on the top of the switch Fig3 no 4 set the main switch to position 1 Fig 1 Power supply unit with the main switch 230V socket Main switch Fi...

Страница 5: ...change MINUS Switching on the heating of knives After entering the menu button no 4 set the temperature of the knives S decreasing the temperature Setting range from 30 C 95 C T current knife temperat...

Страница 6: ...he controller Fig 9 Switching off heating of knives button no 8 When the knives have reached the pre set temperature the machine is ready for uncapping process Then turn on the uncapping knives Fig 10...

Страница 7: ...s 3 8 Discs piercing uncapped cells in the frame in Fig 17 close up view 3 1 General rules preparation for use Before starting uncapping adjust the sliders 6 Fig 15 with the screws shown in Fig 16 Fig...

Страница 8: ...n the heating of the knives again Wait for the reheating of the uncapping knives Start the uncapping machine and return to the uncapping process A Liquid level indicator in closed circuit B Filler por...

Страница 9: ...g sure to protect the electrical components After washing rinse thoroughly with clean water The chain carrying the frames should be dried after washing and do not use any preservatives The uncapping m...

Отзывы: