Lynxspring JENE PC-1000 Series Скачать руководство пользователя страница 2

 

 

 

 

2

 

Trademarks  

 

 

Niagara, Niagara AX is a registered trademark of Tridium, Inc. 

LON, LonWorks and LonTalk are registered trademarks of Echelon Corporation 

BACnet is a registered trademark of ASHRAE 

 

Disclaimers  

 

 

NO WARRANTY. Lynxspring, Inc. (herein after referred to as “Lynxspring”) makes no warranty as to the 
accuracy of or use of this technical documentation. Any use of the technical documentation or the information 
contained therein is solely at the risk of the user.  
 
Documentation may include technical or other inaccuracies or typographical errors. Lynxspring reserves the right 
to make changes to this document without prior notice, and the reader should in all cases consult Lynxspring to 
determine whether any such changes have been made. The information in this publication does not represent a 
commitment on the part of Lynxspring. 
 
Lynxspring shall not be liable for incidental or consequential damages resulting from the furnishing, performance, 
or use of this material. 
 
This guide contains links and references to third-party websites that are not under the control of Lynxspring, and 
Lynxspring is not responsible for the content of any reference material or linked websites. If you access a third 
party website mentioned in this guide, then you do so at your own risk. Lynxspring provides these links only as a 
convenience, and the inclusion of the link does not imply that Lynxspring endorses or accepts any responsibility 
for the content on those third-party sites. 
 
Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and installing 
the Lynxspring wireless gateway. 
 
All Lynxspring wireless gateways and related wireless thermostats are to be used only as operating controls. 
Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of 
the user to add safety devices and/or alarm system to protect against such catastrophic failures. 
 
All VT7000 series wireless thermostats and associated components have been rigorously tested to ensure 
reliable operation in most building applications using the latest 2.4 ZigBee technologies. Lynxspring cannot 
guarantee against potential network interference should additional wireless systems be deployed sharing close 
proximity. 
 
Best practices covered in this manual and all related Lynxspring documents should be considered as a guide to 
apply Lynxspring Wireless Network devices only. The instructions included in this manual are based upon 
Lynxspring in house testing and should be referred to as a guide only. 
 
Lynxspring Inc. may not be held liable for continued reliable, or robust operation of any and all wireless based 
devices. Although Lynxspring has taken many precautions in assuring the robustness of the VT7000 series 
wireless thermostat product line and associated network access point (JENE’s with wireless option card) Please 
note; future application of additional wireless devices utilizing the same or similar channels and / or frequencies 
may degrade performance of overall system and / or reliability. 
 
Non-approved modifications or changes made to the communication card, the wireless thermostat driver or 
wireless thermostats may void the FCC compliance of the wireless card and wireless thermostats.  
 
Ferrites supplied with the power supply and VWG MUST be installed according to instructions. Failure to do so 
may void the FCC compliance of the wireless card and wireless thermostats.  
 
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE 
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) 
THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY 
CAUSE UNDESIRED OPERATION.

 

 

Содержание JENE PC-1000 Series

Страница 1: ...agara AX powered JENE controllers When utilized in conjunction with the VT7xxxXxxxxW series wireless thermostats they offer the integrator simple integration to the Niagara AX environment The application is targeted at retrofit applications where the addition of communicating field bus wiring within the building space is prohibitive The JENE communication card and associated Wireless Communicating...

Страница 2: ...ld lead to personal injury and or loss of property it becomes the responsibility of the user to add safety devices and or alarm system to protect against such catastrophic failures All VT7000 series wireless thermostats and associated components have been rigorously tested to ensure reliable operation in most building applications using the latest 2 4 ZigBee technologies Lynxspring cannot guarante...

Страница 3: ... contention based and contention free channel access methods are supported with a maximum packet size of 128 bytes which includes a variable payload up to 104 bytes Also employed are 64 bit IEEE and 16 bit short addressing supporting over 65 000 nodes per network All those properties of the physical layer are used and employed by the Lynxspring mesh network but are hidden to the installed user for...

Страница 4: ...vices in the 2 4GHz spectrum range Lynxspring recommends the use of 802 15 4 channels 25 and 26 only 802 11 Wi Fi transmissions overlap and may interfere with other channel selection allowed by 802 15 4 Channels 11 to 24 2 Maximum distance between each node thermostat should be Clear line of sight between 2 nodes should be under 100 feet 30 M Maximum 100 feet 30 M between 2 thermostat nodes Open c...

Страница 5: ... tops using wireless networks etc to be at least 3 foot 1 M and preferably 10 feet 3 M or more Maximum 30 feet 10 M between 2 thermostat nodes Minimum 3 feet 1 M between Wi Fi equipment and Lynxspring wireless d i Preferably 10 feet 3 M or more between Wi Fi equipment and Lynxspring wireless devices Non line of sight maximum distance for typical gypsum wall partitions should be maximum of 30 feet ...

Страница 6: ...obstructions between wireless devices as much as possible 8 Make sure the antenna on the VWG is always perpendicular to the floor 9 Avoid placing VWG and thermostats near metal or enclosed in metal boxes If the VWG needs to be installed inside a metal cabinet use the remote antenna accessory Ex For a recommended maximum of 30 wireless thermostats total per JENE a minimum of 3 of them should be wit...

Страница 7: ...y the WirelessStatNetwork jar file to your local module folder Using the Software Manager add the WirelessStat jar file to the target JENE with the wireless communication card already installed Re boot both the local Niagara AX interface and the JENE itself to properly load the WirelessStatNetwork jar module Using the WirelessStat palette tool simply drag drop the WirelessStatNetwork driver under ...

Страница 8: ...WirelessStatNetwork driver and load the property sheet Under the Serial Port Configuration set Port Name to COM1 Only COM1 can be used with the wireless communication card All other properties are locked and set as read only ...

Страница 9: ...igned wireless address information is given for reference only It is important to click on the SAVE button for the new wireless parameters to take effect and the wireless network to properly start IMPORTANT NOTES Please Read Carefully For every thermostat reporting to a JENE a maximum of 30 thermostats per JENE is recommended be sure you set the SAME PAN ID and Channel value at both the gateway an...

Страница 10: ...rtbeat to the JENE and is now offline to the VWG It may take up to 2 minutes for a new thermostat device to be automatically discovered and appear under the Discovered Device folder If a properly configured thermostat typically the ones furthest from the JENE has issues joining the network and cannot be discovered by the JENE bring it and power it closer to the JENE coordinator This will get enabl...

Страница 11: ...und to manage the thermostat devices database New The New thermostat button is a utility that allows the integrator to create offline devices prior to the installation This allows the integrator to pre build a database and all related utilities before the actual installation takes place When the assigned thermostat would be automatically discovered in the field during commissioning all required fu...

Страница 12: ...artbeat reporting properly with no fault encountered o down Device heartbeat failed No communication to the device o fault Transaction time out on specific object write s Device heartbeat is still valid o disabled fault Device has been disabled Enabled Enables or disables the communication to the wireless thermostat Can be used if a complete database is created for all the devices but it is done i...

Страница 13: ...ess It is important that once the station is all done and installed with all GUI services trends logs etc that resources are monitored and not above what is recommended by Lynxspring for each specific type of JENE controller The list of points available for each thermostat model is different and has been optimized to best suit typical applications used by every single typical thermostat model avai...

Страница 14: ...UnoccCoolSetpoint Numeric Present_Value R W UnoccHeatSetpoint Numeric Present_Value R W DehumidRHSetpoint Numeric Present_Value R W HumidificationRHSetpoint Numeric Present_Value R W EffectiveHumidificationRHSetpoint Numeric Present_Value R W HumidificationHighLimitSetpoint Numeric Present_Value R W Main Commands OccupancyCommand Enum Present_Value R W SequenceOfOperation Enum Present_Value R W Sy...

Страница 15: ...e R EconomizerOutput Numeric Present_Value R Alarms Enum Present_Value R Output Status FanStatus Enum Present_Value R GFanStatus Boolean Present_Value R W2Stratus Boolean Present_Value R W1Status Boolean Present_Value R Y1Status Boolean Present_Value R Y2Status Boolean Present_Value R ReversingValveStatus Boolean Present_Value R AuxStatus Boolean Present_Value R DI1Status Boolean Present_Value R D...

Страница 16: ... and Room Humidity need to be set Out Of Service if you want to write to the object present value When Out Of Service is set to True the thermostat local present value will be derived from the wireless network instead of the present value at the thermostat List of Property Enumeration Sets for BV Objects Object Name Object Type Inactive_Text Active_Text Default value AuxCommand Boolean Off On Off ...

Страница 17: ...system mode and also restrict the usable range that a local thermostat can accept Note 2 Note 1 For VT72xx VT73xx devices usable enumerations for the System Mode depends on Sequence of Operation selected The Auto mode can be used only if the AutoMode configuration parameter is set to On Note 2 Default value of System Mode depends on the Local Sequence of Operation selected and the value of the Aut...

Страница 18: ...Last valid thermostat value Index accepted for all VT7200 are 1 2 5 6 Index accepted for all VT7300 are 1 2 3 4 5 6 Index accepted for all VT7600 are 1 2 3 1 1 No Alarm 2 2 Window Alarm 3 3 Filter Alarm 4 4 Service Alarm 5 5 Window Filter Alarms 6 6 Window Service Alarms Alarms For VT7200 VT7300 Enum 7 7 Filter Service Alarms Index exposed for all VT7200 and VT7300 are dependent on local thermosta...

Страница 19: ...figure shows which typical objects from each thermostat attached to a VWG can be monitored and commanded from the front end Global Command Control Level Device Level Figure 1 Global commands from a BAS front end to a JENE and associated thermostat ...

Страница 20: ...noccupied Heat Setpoints Numeric Occupied and Unoccupied Cool Setpoints Numeric Outdoor Temperature Numeric Supply Temperature Numeric If available Occupancy Command Enum System Mode Enum Heating Valve Status Enum Cooling Valve Status Enum PI Heating Demand Numeric PI Cooling Demand Numeric Window Alarm Boolean Filter Alarm Boolean Service Alarm Boolean ...

Страница 21: ...ed Cool Setpoints Numeric Room Humidity Numeric If available Room Humidity Setpoint Numeric If available Outdoor Temperature Numeric Supply Temperature Numeric If available Occupancy Command Enum System Mode Enum Fan Mode Enum Fan Status Enum Heating Valve Status Enum Cooling Valve Status Enum PI Heating Demand Numeric PI Cooling Demand Numeric Window Alarm Boolean Filter Alarm Boolean Service Ala...

Страница 22: ...tem Mode RTU Enum or System Mode HPU Enum G Fan Boolean Y1 Cool Boolean Y2 Cool Boolean W1 Heat Boolean W2 Heat Boolean or Reversing Valve Boolean Economizer Output Numeric if available Aux Boolean DI 1 Status Boolean DI 2 Status Boolean Frost Alarm Boolean if available Filter Alarm Boolean if available Service Alarm Boolean if available Fan Lock Alarm Boolean if available BI 38 AV22 BI 25 BI 26 B...

Страница 23: ...ccessfully 4 x 200ms short blinks and 1 x 1500ms long blink Power on card memory initialized properly serial communication with VWG main board active wireless networks started successfully and wireless communication with thermostats active Thermostat Wireless Adapter LED Status Indicators 1 x 200ms short blink Power on 2 x 200ms short blinks Power on and communicating with thermostat 3 x 200ms sho...

Страница 24: ...ee addresses Duplicated ZigBee addresses created during commissioning 1 Assure that PAN ID and Channel settings are secured prior to network discovery 2 Change PAN ID of all thermostat and associated gateway 3 Redo a wireless network discovery Document Control Document Name Lynxspring Wireless Thermostat Driver Guide Document Filename ITG VWG AP 1020 LNX E03 doc Revision Date Changes 00 November 0...

Отзывы: