background image

To prevent SERIOUS INJURY or DEATH: 

• 

DO NOT connect electric power until instructed to 

do so.

• 

ALWAYS call a trained professional door 

serviceman if door binds, sticks or is out of balance. 

An unbalanced door may not reverse when 

required.

• 

NEVER try to loosen, move or adjust doors, door 

springs, cables, pulleys, brackets or their hardware, 

ALL of which are under EXTREME tension and can cause 

SERIOUS PERSONAL INJURY.

• 

DISABLE ALL locks and remove ALL ropes connected to 

door BEFORE installing and operating door operator to avoid 

entanglement.

MOTOR

It is imperative that the wall or mounting surface  provide 

adequate support for the operator.

The surface must:

a.  Be rigid to prevent play between operator and door 

shaft. (Spreader bars will also be of aid when the door 

shaft  is not supported properly by an end bearing)

b.  Provide a level base

c.  Permit the operator to be fastened securely and with 

the drive shaft parallel to the door shaft.

The safety and wear of the operator will be adversely 

effected if any of the above requirements are not met.

For metal buildings, fasten 2” x 2” x 3/16” (or larger) angle 

iron frames to the building purlins. Retain 7-1/2” between 

frames (Figure 1).

SAFETY

SPECIFICATIONS

TYPE:

Intermittent duty

HP:

1/2 HP

SPEED:

1500 RPM

VOLTAGE:

115V 1 Phase 60Hz

CURRENT:

See motor nameplate

ELECTRICAL

TRANSFORMER:

24VAC

CONTROL STATION:

3-button station                 

OPEN/CLOSE/STOP

WIRING TYPE:

B2 (Standard, when powered)
C2 (When photoeyes are 

blocked or not present)

LIMIT ADJUST:

Linear driven, fully adjustable 

screw type cams. Adjustable to 

24 feet.

MDJ, MDJH, MDJB, MDJBH

MECHANICAL

SAFETY

PREPARATION

MDJ, MDJH, MDJB, MDJBH

All MDJ, MDJH, MDJB, and MDJBH operators have dual 

output shafts and may be mounted on either the right 

(standard) or the left side of the door.  Install the sprocket on 

the side desired and insert the key.  Be sure to tighten Both 

set screws securely.

DRIVE REDUCTION:

Primary: Heavy duty (4L) V-Belt
Secondary: #41 chain/sprocket 
Output: #41 chain

OUTPUT SHAFT 

SPEED:

27 RPM

DOOR SPEED:

Approx. 5.4” per sec. depending 

on door.

BRAKE (Optional):

Solenoid actuated drum brake

BEARINGS/BUSH-

INGS:

Ball bearing with hardened 

races & Oil Impregnated 

Bushings

HAND CHAIN 

WHEEL(optional):

Left or Right

DIMENSIONS & WEIGHT

HANGING WEIGHT:

65-75 LBS

SHIPPING WEIGHT:

85-95 LBS

DISCONNECT:

All Models: Floor level 

disconnect for manual door 

operation.

REVERSING EDGE:

(Optional) Electric or pneumatic 

sensing device attached to 

the bottom edge of door. 

A REVERSING EDGE IS 

STRONGLY RECOMMENDED

FOR ALL COMMERCIAL 

OPERATOR INSTALLATIONS. 

REQUIRED WHEN THE 3 

BUTTON CONTROL STATION 

IS OUT OF SIGHT OF DOOR 

OR ANY OTHER CONTROL 

(AUTOMATIC OR MANUAL) IS 

USED.

WARNING

WARNING

TO ACCOMODATE

10" HOLE SPACING

2

3

Improperly operating or 

an unbalanced door could 

cause SERIOUS INJURY 

or DEATH.  

See Door 

Manufacturer’s Owner’s Manual.  Have trained 

door systems technicians make repairs to 

cables, spring assemblies, and other hardware.

IMPORTANT NOTE: To aid installation, see page 16 

(Shop Drawing) for mounting consideration.

Содержание MDJ

Страница 1: ...M DUTY JACK SHAFT OPERATOR READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS This unit is intended for limited duty applications not to exceed 12 cycles of opening and closing per hour NOT FOR RESIDENTIAL USE 0MAGA0AA CDJ MANUAL 03 ...

Страница 2: ...B2 Standard when powered C2 When photoeyes are blocked or not present LIMIT ADJUST Linear driven fully adjustable screw type cams Adjustable to 24 feet MDJ MDJH MDJB MDJBH MECHANICAL SAFETY PREPARATION MDJ MDJH MDJB MDJBH All MDJ MDJH MDJB and MDJBH operators have dual output shafts and may be mounted on either the right standard or the left side of the door Install the sprocket on the side desire...

Страница 3: ...with BOTH set screws 2 Install Hand Chain Models MDJH and MDJBH only Thread hand chain around hand chain wheel ensuring that it passes through both openings in the hand chain guide Remove enough links that so that the loop hangs approximately two feet above the floor 3 Mount Manual Disconnect Chain Keeper Using suitable hardware mount the manual disconnect directly beneath the operator approximate...

Страница 4: ...s Near and Opposite Side SENSING EDGES All types of sensing edges with an isolated normally open N O output are compatible with your operator This includes pneumatic and electric edges If your door does not have a bottom sensing edge and you wish to purchase one contact the supplier of your operator If not pre installed by the door manufacturer mount the sensing edge on the door according to the i...

Страница 5: ...ROL WIRING MDJ MDJH MDJB MDJBH IMPORTANT NOTE Mount warning notice beside or below the push button station WARNING WARNING 8 MDJ MDJH MDJB MDJBH 9 PHOTO EYE INSTALLATION 1 Make sure that power is disconnected to the system prior to installing the photo eyes 2 Photo eyes need to be mounted inside the building They should be mounted on either side of the door and as close as possible to the door tra...

Страница 6: ...ivating an OPEN button without the need to use the STOP button first for all 3 Modes To reduce the risk of serious injury or death follow these instructions carefully Read and follow ALL instructions Keep fingers and other body parts away from all moving parts of the door and gate operator system while it is being operated Keep the radio controls away from children Do not allow children to play wi...

Страница 7: ...ic or manual is used Reversing devices are recommended for ALL installations CLUTCH ADJUSTMENT 1 Loosen the adjustment jam nuts until there is little tension on the clutch spring 2 Tighten the inner jam nut gradually until there is just enough tension to permit the operator to move the door smoothly but to allow the clutch to slip if the door is obstructed When the clutch is properly adjusted it s...

Страница 8: ...RITY SENSITIVE NORMALLY OPEN SAFETY DEVICE OPTIONAL MOMENTARY SWITCH INTERLOCK WHEN NEEDED Rev 09 11 15 LX 900 Wiring Connections COAXIAL ANTENNA CONNECTION Stop and Com must be jumpered when a 3 Button Wall Station is not Present MDJ MDJH MDJB MDJBH 15 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF NAPOLEON LYNX ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISS...

Страница 9: ...SHOP DRAWING MDJ MDJH MDJB MDJBH 16 14 1 15 4 18 0 0 750 10 0 1 50 TYP 0 50 0 406 18 0 5 5 6 5 5 0 TYP ...

Отзывы: