background image

Installation Instructions

Wall Hoods

Outdoor Applications

IMPORTANT  SAFETY  INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.

IMPORTANT:

INSTALLER:

OWNER:

SAFETY WARNING:

Save these instructions for the Local Electrical Inspector’s use.

Please leave these instructions with this unit for the owner.

Please retain these instructions for future reference.

Turn off power circuit at the service panel and lock out panel,

before wiring this unit.

 

CAUTION - TO REDUCE THE RISK
OF  FIRE,  ELECTRIC  SHOCK,  OR
INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

1. Use this unit only in the manner 

intended by the manufacturer.  If you 
have any questions, contact 
Lynx Grills, Inc. (888) 289-5969

2. Before servicing or cleaning the unit, 

switch power off at service panel and 
lock the service disconnecting means to
prevent power from being switched on
accidentally. When the service 
disconnecting means cannot be locked,
attach a tag to the service panel to 
indicate power has been switched off 
for maintenance.

3.  Install this Rangehood Only with 

Remote Blower Models Rated 
Maximum 12.8A or Integral Blowers 
Models LOHI and LOHE.

C AU T I O N :   F O R   G E N E R A L
VENTILATION USE ONLY. DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE MATERIALS OR VAPOR.

BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately.
EVACUATE AND CALL THE FIRE 
DEPARTMENT.

3.

2. DO NOT USE WATER, including wet

dish-cloths or towels - a violent steam 
explosion will result.

Use  an  extinguisher 

ONLY

  if:

a.You  know  you  have  a  class  ABC

extinguisher, and you already know
how to operate it.

b.The fire is small and contained in

the area where it started.

c. The fire department is being called.

d.You can fight the fire with your back

to an exit.

CAUTION - TO REDUCE THE RISK
OF  FIRE:

1. Never leave grill unattended.

2. Always turn hood ON when cooking.

3. Clean  ventilating  fans  frequently.

Grease should not be allowed to 
accumulate on fan or filter.

CAUTION - TO REDUCE THE RISK
OF  INJURY TO  PERSONS,  IN THE

1.

1

EVENT  GREASE  FIRE,  OBSERVE 
THE FOLLOWING:

Содержание LOH36

Страница 1: ...means cannot be locked attach a tag to the service panel to indicate power has been switched off for maintenance 3 Install this Rangehood Only with Remote Blower Models Rated Maximum 12 8A or Integra...

Страница 2: ...n accordance with all requirements specified by the manufacturer G Install this hood using required clearance from cooking surface to combustible material specified by the manufacturer READ AND SAVE T...

Страница 3: ...op of the hood is flush with the ceiling 4 Insert all four of the allthread bolts into the top of the hood Approximately 3 5 While lifting the hood guide and position the allthread through the 2x4s Un...

Страница 4: ...ROUGH IN PLATE MOUNTED TYPICAL INSTALLATION 30 to 36 cooktop filter grease trough hood ceiling 10 round duct transition rough in plate lag screws Figure A Vertical Discharge 4...

Страница 5: ...screws on the back of the unit as shown in Figure 1 3 Detach the transition from the rough in plate by removing four 4 screws The shipping screws are needed for re attaching the transition to the roug...

Страница 6: ...EAL ALL JOINTS WITH DUCT TAPE STEP 2 MOUNTING THE IN HOOD FAN 1 Install the fan by aligning the holes on the fan to the weld studs on the rough in plate Tighten the fan to the plate using the hex nuts...

Страница 7: ...the rough in plate hole 3 Remove the junction box from the rough in plate Connect black wire to power supply black wire white wire to power supply white wire and green wire to power supply green wire...

Страница 8: ...w enough room for duct cover width on the top section of the rough in plate 2 Slide Duct Cover into opening 3 Attach Duct Cover from the inside of the hood through filter opening using the screws prov...

Страница 9: ...nter of the space provided for the filters insert one filter on the top ledge and pull back until the bottom of the filter slips into bottom ledge 3 Slide the filter to one side 4 Install the next fil...

Страница 10: ...ft Volumetric Flow Rate CFM Duct Dimensions 10 dia 9 dia 8 dia LOHE REMOTE FAN 261 4 203 4 10 28 14 4 17 APPLICATION Maximum CFM 1200 Electrical Motor Rating 8 0 Amps 115V AC 60 Hz Duct Size at Disch...

Страница 11: ...11...

Страница 12: ...f the hood INTERIOR OF HOOD All hoods are fitted with a brushed stainless steel liner For cleaning we recommend using pre washed flannel cloths and Stainless Steel cleaner Always wipe in a manner whic...

Страница 13: ...r design without notice Some models are certified for use in Canada Lynx is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian d...

Страница 14: ...lectrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhaustin...

Страница 15: ...28 5 7 8 B C E F G I H REMOTE VENTILATOR DIMENSIONS Fig 5 A ROUND DUCT ROOF ELBOW TAPE JOINT 1 2 CONDUIT NOT INCLUDED TYPICAL INSTALLATION ELBOW ROUND DUCT TRANSITION DIRECT DUCT INSTALLATION Fig 4 TR...

Страница 16: ...r installation on a flat roof or roofs with pitch less than 1 1 2 in 12 inches install LOHE on curb so that the discharge low end points away from prevailing winds 3 Install the remote fan on the roof...

Страница 17: ...alls to the remote ventilator using color coded wires corresponding to color codes indicated in figure 8 4 The white plastic Molex electrical connector inside the hood feeds the power to the remote ve...

Страница 18: ...5...

Страница 19: ...REMOVE VENTILATION TIPS 1 Leave Appliances such as Ranges Cooktops Barbecue Units Grills etc require adequate ventilation Hood should be large enough and Cooking Appliances located so that the Hood o...