USE AND CARE

CONTROLS

FAN

The  fan  is  controlled  by  a  multi-speed  switch.  Printed

speeds on the control panel correspond with fan speed.

COOKTOP LIGHTING

USE ONLY R20 SIZE, HALOGEN 50 WATT BULBS

FILTERS

Wash filters frequently either in a detergent solution, or by

placing them in your dishwasher.

Replacement  filters  may  be  purchased  from  Lynx.

CLEANING

Do not allow excessive grease to accumulate. Refer to Cleaning

Recommendations  on  last  page  for  suggestions  on  cleaning

metals and finishes.

DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS,

OR SCOURING POWDERS.

Vacuum  fan  to  eliminate  collected  dust  and  particles.

Do not immerse fan in water.

REPLACEMENT PARTS

For purchasing replacement parts, contact Lynx.

1. Grease trough location is on the underside (bottom), rear 

area of hood.

2. In the center of the space provided for the filters, insert one

filter on the top ledge and pull back until the bottom of 

the filter slips into bottom ledge.

3. Slide the filter to one side.

4. Install the next filter by repeating step 2. There will be some

side-to-side and front-to-back tension as the filters line up.

5. Install halogen bulbs. Use R20 size, 50 watt maximum, 

narrow  flood  light  bulbs  only  (purchased  separately).

INSTALLATION OF GREASE TROUGHS, FILTERS, LAMPS

Hood Assembly

Baffle or Mesh

filter

grease trough

Always turn the hood on before cooking to establish an air 

flow. Allow the fan to operate for a few minutes to clear 

the air after you turn the grill off. This will help keep the 

area smoke free and fresher smelling.

The halogen lights are controlled with two (ambient and 

brilliant) rotary switches. The lights can be turned on 

individually or simultaneously. To use the lights on 

brilliant setting, rotate switches clockwise.  For ambient 

setting, rotate switches counter clockwise.

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Содержание LOH1236

Страница 1: ...o the service panel to indicate power has been switched off for maintenance 3 Install this Rangehood Only with Remote Blower Models Rated Maximum 12 8A or Integral Blowers Models LOHI and LOHE C AU T...

Страница 2: ...cified by the manufacturer G Install this hood using required clearance from cooking surface to combustible material specified by the manufacturer READ AND SAVE THESE INSTRUCTIONS The high degree of c...

Страница 3: ...ng 4 Insert all four of the allthread bolts into the top of the hood Approximately 3 5 While lifting the hood guide and position the allthread through the 2x4s Unistrut or Angle Iron At least 2 people...

Страница 4: ...ICAL INSTALLATION 30 to 36 cooktop filter grease trough hood ceiling 10 round duct transition rough in plate lag screws Figure A Vertical Discharge 4 NorthlineExpress com http www northlineexpress com...

Страница 5: ...n in Figure 1 3 Detach the transition from the rough in plate by removing four 4 screws The shipping screws are needed for re attaching the transition to the rough in plate 4 Secure the transition to...

Страница 6: ...OUNTING THE IN HOOD FAN 1 Install the fan by aligning the holes on the fan to the weld studs on the rough in plate Tighten the fan to the plate using the hex nuts 2 Plug the Molex plug on the fan to t...

Страница 7: ...unction box from the rough in plate Connect black wire to power supply black wire white wire to power supply white wire and green wire to power supply green wire 4 Place all wiring connectors inside j...

Страница 8: ...the top section of the rough in plate 2 Slide Duct Cover into opening 3 Attach Duct Cover from the inside of the hood through filter opening using the screws provided See figure 8 Note Do not complete...

Страница 9: ...ters insert one filter on the top ledge and pull back until the bottom of the filter slips into bottom ledge 3 Slide the filter to one side 4 Install the next filter by repeating step 2 There will be...

Страница 10: ...nsions 10 dia 9 dia 8 dia LOHE REMOTE FAN 261 4 203 4 10 28 14 4 17 APPLICATION Maximum CFM 1200 Electrical Motor Rating 8 0 Amps 115V AC 60 Hz Duct Size at Discharge 8 X 21 1 4 X 10 Round Transition...

Страница 11: ...11 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 12: ...are fitted with a brushed stainless steel liner For cleaning we recommend using pre washed flannel cloths and Stainless Steel cleaner Always wipe in a manner which follows the grain DO NOT clean with...

Страница 13: ...e certified for use in Canada Lynx is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian distributor or dealer UL C FILE 204107...

Страница 14: ...fied person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of...

Страница 15: ...OR DIMENSIONS Fig 5 A ROUND DUCT ROOF ELBOW TAPE JOINT 1 2 CONDUIT NOT INCLUDED TYPICAL INSTALLATION ELBOW ROUND DUCT TRANSITION DIRECT DUCT INSTALLATION Fig 4 TRANSITION OUTSIDE WALL ELBOW WALL INSTA...

Страница 16: ...with pitch less than 1 1 2 in 12 inches install LOHE on curb so that the discharge low end points away from prevailing winds 3 Install the remote fan on the roof or wall with discharge pointing down...

Страница 17: ...lor coded wires corresponding to color codes indicated in figure 8 4 The white plastic Molex electrical connector inside the hood feeds the power to the remote ventilator Use the receptacle connector...

Страница 18: ...5 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 19: ...ances such as Ranges Cooktops Barbecue Units Grills etc require adequate ventilation Hood should be large enough and Cooking Appliances located so that the Hood overhangs the Cooking Surface as much a...

Отзывы: