Lynx LOH1236 Скачать руководство пользователя страница 2

CAUTION -
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO
P E R S O N S ,   O B S E RV E   T H E
FOLLOWING:

C AU T I O N :   F O R   G E N E R A L
VENTILATION  USE ONLY.  DO NOT
USE TO EXHAUST HAZARDOUS OR
EXPLOSIVE  MATERIALS  OR
VAPORS.

A. Installation work and electrical wiring

must be done by a qualified person
in accordance with all applicable 
codes and standards, including fire-
rated construction.

B. Sufficient air is needed for  proper 

combustion and exhausting of gases 
through the flue (chimney) of fuel 
burning equipment to prevent 

backdrafting. Follow the heating 
equipment manufacturer’s guidelines 
and safety standards such as those 
published by the National Fire 
Protection Association (NFPA), and 
the American Society for Heating, 
Refrigeration and Air Conditioning 
Engineers (ASHRAE), and the local 
code authorities.

C. When cutting or drilling into a wall or

ceiling, do not damage electrical 
wiring  and  other  hidden  utilities.

D. Ducted fans must always be vented to

the outdoors.

IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION

E. CAUTION - TO REDUCE THE 

RISK OF FIRE, USE ONLY 
METAL DUCTWORK.

F. Install this hood in accordance with 

all requirements specified by the 
manufacturer.

G. Install this hood using required 

clearance from cooking surface to 
combustible material specified by
the manufacturer.

READ AND SAVE THESE INSTRUCTIONS

The high degree of craftsmanship in the construction and finish

of your hood requires careful handling to ensure proper 

installation.

• Do not remove your hood from its carton until you are ready

to hang it.

• Do not store your hood anywhere other than within the carton.

If it is necessary to remove your hood from the carton, arrange

it on a blanket or padded area that will protect your hood 

from scratches or indentations.

• Do not lift the hood by its utensil rail. Place your fingers under

the  lower  reveal  of  the  hood.  Grasp  firmly  and  lift.

• Cotton gloves are preferable. They will protect the surface 

from fine scratches and eliminate fingerprints.

INSTALLATION  PRECAUTIONS

• Remove  all  rings,  watches,  belt  buckles,  and  jackets 

(snaps-zippers)  to  prevent  scratch  marks.

• Do  not  remove  the  cotton  flannel  from  your  hood  until

the  installation  process  is  complete.  It  will  be  necessary 

to  remove  only  a  small  portion  on  the  back-side  of  a  wall

mounted  hood  in  order  to  position  in  place.

• Located  within  the  hood  cavity  (behind  the  baffle  filter)

are  component  parts  and  halogen  bulbs.

2

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Содержание LOH1236

Страница 1: ...o the service panel to indicate power has been switched off for maintenance 3 Install this Rangehood Only with Remote Blower Models Rated Maximum 12 8A or Integral Blowers Models LOHI and LOHE C AU T...

Страница 2: ...cified by the manufacturer G Install this hood using required clearance from cooking surface to combustible material specified by the manufacturer READ AND SAVE THESE INSTRUCTIONS The high degree of c...

Страница 3: ...ng 4 Insert all four of the allthread bolts into the top of the hood Approximately 3 5 While lifting the hood guide and position the allthread through the 2x4s Unistrut or Angle Iron At least 2 people...

Страница 4: ...ICAL INSTALLATION 30 to 36 cooktop filter grease trough hood ceiling 10 round duct transition rough in plate lag screws Figure A Vertical Discharge 4 NorthlineExpress com http www northlineexpress com...

Страница 5: ...n in Figure 1 3 Detach the transition from the rough in plate by removing four 4 screws The shipping screws are needed for re attaching the transition to the rough in plate 4 Secure the transition to...

Страница 6: ...OUNTING THE IN HOOD FAN 1 Install the fan by aligning the holes on the fan to the weld studs on the rough in plate Tighten the fan to the plate using the hex nuts 2 Plug the Molex plug on the fan to t...

Страница 7: ...unction box from the rough in plate Connect black wire to power supply black wire white wire to power supply white wire and green wire to power supply green wire 4 Place all wiring connectors inside j...

Страница 8: ...the top section of the rough in plate 2 Slide Duct Cover into opening 3 Attach Duct Cover from the inside of the hood through filter opening using the screws provided See figure 8 Note Do not complete...

Страница 9: ...ters insert one filter on the top ledge and pull back until the bottom of the filter slips into bottom ledge 3 Slide the filter to one side 4 Install the next filter by repeating step 2 There will be...

Страница 10: ...nsions 10 dia 9 dia 8 dia LOHE REMOTE FAN 261 4 203 4 10 28 14 4 17 APPLICATION Maximum CFM 1200 Electrical Motor Rating 8 0 Amps 115V AC 60 Hz Duct Size at Discharge 8 X 21 1 4 X 10 Round Transition...

Страница 11: ...11 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 12: ...are fitted with a brushed stainless steel liner For cleaning we recommend using pre washed flannel cloths and Stainless Steel cleaner Always wipe in a manner which follows the grain DO NOT clean with...

Страница 13: ...e certified for use in Canada Lynx is not responsible for products which are transported from the United States for use in Canada Check with your local Canadian distributor or dealer UL C FILE 204107...

Страница 14: ...fied person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of...

Страница 15: ...OR DIMENSIONS Fig 5 A ROUND DUCT ROOF ELBOW TAPE JOINT 1 2 CONDUIT NOT INCLUDED TYPICAL INSTALLATION ELBOW ROUND DUCT TRANSITION DIRECT DUCT INSTALLATION Fig 4 TRANSITION OUTSIDE WALL ELBOW WALL INSTA...

Страница 16: ...with pitch less than 1 1 2 in 12 inches install LOHE on curb so that the discharge low end points away from prevailing winds 3 Install the remote fan on the roof or wall with discharge pointing down...

Страница 17: ...lor coded wires corresponding to color codes indicated in figure 8 4 The white plastic Molex electrical connector inside the hood feeds the power to the remote ventilator Use the receptacle connector...

Страница 18: ...5 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 19: ...ances such as Ranges Cooktops Barbecue Units Grills etc require adequate ventilation Hood should be large enough and Cooking Appliances located so that the Hood overhangs the Cooking Surface as much a...