background image

 

Lynx

 

Model

 

No.

 

LHFS

 

Page

 

27

 

P/N

 

33348

   

Rev.

 

A

   

7/2010

 

Maintenance and Trouble Shooting 

Parts Reference 

Item Description 

Part 

No. 

Qty Item 

Description 

Part 

No. 

Qty 

1 Weight 

EH014 

21 

Valve & Burner 
Housing Base 

ES101 1 

2 Base 

Skin 

ES087 

22 

Tip 

(Tilt) Over Switch 

EE029 

Wheel Dustproof 
Cover 

- 2 

23 

Electronic 

Igniter  EE028 

4 Wheel 

EH015 

24 

Valve 

Support 

ES102 

5 Wheel 

Axle 

ES091 

25 

Valve 

EG024 

Wheel Mounting 
Bracket 

ES090 1 26  Knob 

EH016 1 

7 Base 

Bracket 

ES088 

27 

Valve Housing Cover 
and wind guard Assy 

ES104 1 

Tank Base Retainer 

ES089 

28 

Valve and burner 
Housing 

ES103 1 

Base Support Pillars 

ES093 

29 

Shield Support Arm 
Base 

ES105 4 

10 Base 

Body 

ES094 1 30 Pilot Assembly 

EG026 

11 

Tank Saddle 

ES092 

31 

Shield Support Arm 

ES106 

12 

Door (Outer) 

ES095 

32 

Main Burner 

ES107 

13 Door 

(Inner) 

ES096 1 33 

Venture and Burner 
Screen 

ES108 1 

14 Handle 

EH017 1 34 Outer 

Shield 

ES109 4 

15 Door 

Filler 

ES097 1 35 

Shield Support Arm 
Fingers 

ES110 4 

16 Door 

Spring 

EH018 1 36 

Emitter Top and Side 
Ring 

ES111 1 

17 

Regulator and Hose 
Assembly 

EG025 1 37  Reflector 

ES112 1 

18 

Pole and Pole Flange 

ET003 

1 38  Table 

(Optional) 

ES099  1 

19 Base 

Cover 

ES098 1 39 

Manual (with Battery) 
not shown 

LT126 1 

20 Pole 

Neck 

ES100 1  

 

 

 

 
IR Energy reserves the right to make improvements to its product line without notice. 

Содержание LHFS

Страница 1: ...se injury death or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other f...

Страница 2: ...ICATIONS 7 CLEARANCE TO COMBUSTIBLE MATERIALS 8 INSTALLATION INSTRUCTIONS 9 SHIPPING CRATE CONTENTS 9 ASSEMBLY OF OUTDOOR PATIO HEATER 11 POSITION MOVE THE HEATER 18 SECURE THE HEATER 19 CONNECTING TH...

Страница 3: ...urns or clothing ignition Young children should be supervised when they are in the area of the heater Playing or running around the structure should be strictly forbidden Clothing or other flammable m...

Страница 4: ...e a 5 minute complete shutoff period before the Heater is re lighted Ensure the LP Gas Cylinder is turned OFF and disconnected prior to moving the Heater Storage of a Heater indoors is permissible onl...

Страница 5: ...n Electrical Code CSA C22 1 For use ONLY with 20 LP Gas Cylinders with a maximum capacity of 8kg 20lb constructed and marked in accordance with national codes USA U S Department of Transportation DOT...

Страница 6: ...ay be considered an indoor location by some code authorities Refer to the National Fuel Gas Code ANSI z 223 1 NFPA 54 in the US and CAN CGA B149 1 and 149 2 installation codes in Canada Safety Require...

Страница 7: ...ylinders with a maximum capacity of 8kg 20 lb which meet the criteria described in the Applicable Regulations section of this manual The Cylinder and its connector fittings must be maintained in good...

Страница 8: ...33 BELOW MODEL No SIDES TOP Combustible materials are considered to be wood compressed paper plant fibres plastic Plexiglas or other materials capable of being ignited and burned Such materials shall...

Страница 9: ...ght Shield Support Arms 4 With Hardware attached Note Follow instructions for un packaging sequence to avoid damage to Burner Wheels With Hardware attached Pole Neck With Hardware attached Outer Shiel...

Страница 10: ...t 6 S S To hold pole to base support 1 4 20 x 1 2 Truss Head Screw with Nut 4 To hold reflector 8M 1 25 X 65 mm Anchor Bolt 3 To hold down heater to concrete foundation 10 x 1 1 2 Wood Screw 3 To hold...

Страница 11: ...dy by pushing down on the handle to disengage the door from the latch Carefully cut the zip ties holding the Gas Hose Assembly to the interior of the Base Body and remove the Burner Be Careful to lift...

Страница 12: ...es located around the Base of the Heater total of three Base Brackets Assemble so that the heads of the Screws are seen from the outside of the Base The side of the Bracket with the remaining hole sho...

Страница 13: ...Base Cover with the Base Body using the eight 8 screws removed previously in Step 1 b OPTIONAL TABLE Installation Point Slide the Table down over the top of the Pole position it in place 8 200 mm up f...

Страница 14: ...e 3 screws in the Base of the Pole Neck piece Insert the Gas Hose Assembly with regulator attached through the Pole Neck Secure the Burner Head to the Pole Neck using the three 3 screws which were rem...

Страница 15: ...emove one of the Fingers from Shield Support Arm then insert the Emitter Ring into the three 3 Shield Support Arms refer to figure A below and re assemble the Finger of last arm refer to figure B belo...

Страница 16: ...urner with regulator attached into the hollow top end of the Pole and feed it all the way through down 11 Secure the Burner Head to the Pole with the Three 3 1 4 20 x 1 2 screws previously removed fro...

Страница 17: ...eflector Secure each bolt with a nut on top of the Reflector Make sure to remove peel off the plastic covering before assembly Warning This heater is equipped with a tilt tip switch for your safety Th...

Страница 18: ...Body It may take two people to manoeuvre the Heater safely depending on the size strength of the person s 3 Tip the Heater backwards at an angle to overtop of the wheels until Base no longer touches...

Страница 19: ...e Bracket is maintained Insert Connect the three Foundation Fasteners as detailed in Table A Foundation Fastener Floor Ground Type Foundation Fastener Type Size Mounting MethodSummary Floor Ground Pre...

Страница 20: ...Instructions Connecting the LP Gas Supply 1 Attach the LP Gas Cylinder to the Tank Base Retainer using the Cylinder Retention Screw Make sure the LP Gas cylinder is in the upright position Keep gas c...

Страница 21: ...Cylinder valve by turning the Regulator clockwise until tight Before using the patio heater Make sure door is shut and stays shut at all time and is not in pedestrian pathway Move Heater to desired l...

Страница 22: ...er shut OFF turn the cylinder valve ON 4 Any leaks will result in bubbles forming in the solution If a leak is indicated shut OFF the cylinder valve 5 Repair any leak have only a licensed technician c...

Страница 23: ...back on 4 Reposition the Valve Housing Cover on the Burner Housing and re secure using the same Four 4 screws 5 Open the gas cylinder valve 6 Push and turn the knob counter clockwise from the OFF posi...

Страница 24: ...lame should resemble image on right 5 If at any time flames extend beyond the emitter surface see image to the right below Improper Flame or black soot is found on the inside of the reflector TURN OFF...

Страница 25: ...here are no cracks in ceramic insulator Ensure the gap spark gap between Pilot and Spark Ignitor electrode is 1 8 3 16 3mm 4 5mm as per picture below 3 Flame lights but will not stay lit Be sure to ho...

Страница 26: ...Lynx Model No LHFS Page 26 P N 33348 Rev A 7 2010 Maintenance and Trouble Shooting Functional Wiring Diagram Ignition Pilot Assembly Valve Tip Switch...

Страница 27: ...Valve and burner Housing ES103 1 9 Base Support Pillars ES093 3 29 Shield Support Arm Base ES105 4 10 Base Body ES094 1 30 Pilot Assembly EG026 1 11 Tank Saddle ES092 1 31 Shield Support Arm ES106 4 1...

Страница 28: ...Lynx Model No LHFS Page 28 P N 33348 Rev A 7 2010 Maintenance and Trouble Shooting...

Страница 29: ...shall the Manufacturer be liable for incidental expense or consequential damages of any kind This warranty does not cover any shipping installation or other costs incurred in the repair or replacemen...

Отзывы: