LEH CARE & USE/INSTALLATION
|
5
This heater must be permanently installed and hard wired by a licensed electrician in accordance with local
electrical codes. Assembly procedure must be performed with no electrical power to unit.
Step 1: Check UL/CUL/CE label on heater for proper voltage.
Step 2: Follow supplied wiring instructions. (See wiring instructions below)
Step 3: Heater must be mounted with reflector angled down.
Step 4: All electrical connections must be in compliance with the National Electric Code (NEC) and local codes
for outdoor wiring.
Step 5: Use only wiring components UL/CUL/CE listed for outdoor use with IPX4 minimum rating.
WIRING INSTRUCTIONS
The heater is drilled and threaded for standard 1/2" conduit fittings. The installing electrician will need to
provide the appropriate rigid metallic, flexible or liquid tight conduit for the installation location.
• Observe local electrical code regulations.
• Remove cover plate from junction box.
• Attach conduit.
• Use only copper wire suitable for 90°C.
• Replace cover plate.
Connect power with
flexible conduit or
appropriate cord to allow
heater to be swiveled.
The Junction Box inlet
hole is sized for a standard
½” weather tight conduit
fitting and has a locknut
located on the inside of the
box for fastening.
INSTALLATION INSTRUCTIONS
WIRING INSTRUCTIONS
Duplex Stack Switch is Included with the heater.
Green ground
wire screw
Junction Box on top of the
heater has a gasket side
access cover.