36
ELECTRICAL CONNECTIONS
warning
- electrIcal groundIng
►
product installation must meet local electric codes or, in the absence of local codes, the latest
edition of the national electrical code ansi/nfpa no. 70 or the canadian electrical code
cga 1.6b2005.
►
use only a ground fault interrupter (gfi) protected circuit with this outdoor cooking gas ap-
pliance.
►
Important:
When connecting your rotisserie motor, first connect the motor to the grill and
then plug the grill into the outlet.
►
This grill is equipped with a three prong (grounding) electric plug for your protection against
shock hazard and must be plugged directly into a properly grounded three prong outlet.
neVeR cut or remove the grounding prong from this plug.
►
Use only extension cords with a 3 prong grounding plug, rated for the power of the equip-
ment, and approved for outdoor use with a “w-a” marking.
►
to protect against electric shock, do not immerse any part of the power cord, an extension
cord or any plugs in water or other liquid.
►
unplug the product from the outlet when not in use and before cleaning. allow it to cool
before putting on or taking off parts.
►
do not let the cord hang over the edge of a table or touch hot surfaces.
►
do not use an outdoor cooking gas appliance for purposes other than intended.
►
do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the
appliance malfunctions or has been damaged in any manner. contact the manufacturer for
repair.
Installation requires an
outdoor 120Vac 15a gfi
(ground fault interrupter)
electrical outlet adjacent to
the grill.
the gfi outlet features an
internal breaker that reduces
shock hazard. this type of
outlet should be installed by
a qualified electrician either
inside the island enclosure
for built-in units, or near the
location where a free-standing
unit will be used.
for built-in grills, the supplied
12V transformer is connected
to the grill during installation.
when installing the trans-
former to the grill be careful
to prevent the wiring and
transformer from contacting
any hot surfaces behind or
below the grill. it is recom-
mended that the transformer
be located below the grill in
a readily accessible location.
Be sure to provide adequate
access to facilitate service if
the transformer or connec-
tions should need future main-
tenance.
if the electrical system fails to
operate, a connection may
have come loose in shipping
or the gfi may have tripped,
requiring a reset. See the
troubleshooting section for
more details.
connectIon to ac
Содержание L24FR-2
Страница 1: ...care use installation MAKE THE MOST OF YOUR...
Страница 30: ...30 cut out dimensions for built in grills...
Страница 39: ...39 Wiring Schematics L27 Non Rotisserie Grill...
Страница 40: ...40 L27 L30 rotisserie Grill...
Страница 41: ...41 L36 L42 rotisserie Grill...
Страница 42: ...42 L54 rotisserie Grill...
Страница 43: ...43 Lynx Professional Grills Exploded Parts View...
Страница 44: ...44 professional grills parts list professional grills parts list...
Страница 46: ...46...