Reference Manual D AD 3220 B Version 1.0

 

Page 14   


Electrical Installation. 

Stand Alone Operation 

The MiniModule requires the R PS 3001 power brick 

option for stand-alone operation. Two versions are 

available R PS 30001 E for European markets and R 

PS 30001 U for the US markets. Please ensure you 

have the correct power option for your region. The 
connection to the module is made with a small 5-

pin connector, which has a twist bayonet securing 

system. Please make sure the connection is solid 
and locked in place. A strain relief is included within 

the module to prevent excessive strain on the 
connection. 

 

Signal connections should be made with care, 

please ensure connections are correct and 

compatible equipment is feeding / receiving the 

signals from the module or damage can result. 
 

 

 

Caution.

 Only use the optional LYNX R PS 

3001 power modules. Please make sure 

the brick is not connected to the main 
supply when making the DC power 

connection to the module. Ensure the 5-

pin power connector is locked securely in 
place. 

 

Caution.

 Care needs to be taken when 

using the module in this way, if it is not 

physically secured. Keep the module 

away from the floor to avoid the risk of 
someone stepping or tripping on the unit, 

and locate the unit away from excessive 

sources of heat and any sources or 
moisture. 

 

Содержание D AD 3220 B

Страница 1: ...k com Reference Manual D AD 3220 B Dual Digital Audio Distribution Amplifier MiniModules Dual Digital Audio Distibution Amp D AD 3220 AES in 1 AES in 2 OUT 1 1 OUT 2 1 OUT 1 2 OUT 2 2 OUT 1 3 OUT 2 3...

Страница 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exc...

Страница 3: ...arranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Страница 4: ...equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause...

Страница 5: ...r Connections 11 DC Power Connector 11 Installation 12 Mechanical 12 Stand Alone Operation 12 Multiple Units 13 Electrical Installation 14 Stand Alone Operation 14 Multiple Units 15 Settings and Contr...

Страница 6: ...Reference Manual D AD 3220 B Version 1 0 Page 6 This Page is intentionally left blank...

Страница 7: ...ES input can have independent sample rates ranging from 32KHz to 108KHz Channel status LED s are provided as well as a front side alarm LED This version of the module features BNC 75 Ohm connections d...

Страница 8: ...gh standard 75 Ohm BNC video connections AES3id Module configuration is set via a small dip switch located behind an access hole in the bottom of the module If the module is being used in a stand alon...

Страница 9: ...AES in 1 AES in 2 OUT 1 1 OUT 2 1 OUT 1 2 OUT 2 2 OUT 1 3 OUT 2 3 OUT 1 4 OUT 2 4 LYNX Technik AG made in Germany www lynx technik com 1 2 3 4 LED 1 LED 2 DIP Switch ON OFF Bottom LED 2 LED 1 Alarm L...

Страница 10: ...ors for AES3 id digital audio Connection is self explanatory We recommend the use of high quality cable suitable for digital applications to reduce the risk of interference or errors due to excessive...

Страница 11: ...locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown below 3 4 5 1 2 GND 5V i2C SDA data i2C SCL clock Power Connection Data C...

Страница 12: ...R 3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with t...

Страница 13: ...Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is...

Страница 14: ...he module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections are correct and compatible equipment is feeding receiving the signals from...

Страница 15: ...via the integral 4 position dip switch This is located on the bottom of the module and can be accessed through the cutout provided fig 2 1 2 3 4 DIP Switch ON OFF LED 2 LED 1 Channel 1 Status Channel...

Страница 16: ...hes may not reflect the actual configuration stored in the module This is because all settings can be changed from the remote control system or via the Service Adapter This overrides the local dip swi...

Страница 17: ...ration Local Adjustment Enabled Switch 1 ON Dual 2 x 1 4 mode Switch 2 ON If this is the mode of operation required then no adjustments are necessary Auto Store If no parameters are changed for 10 sec...

Страница 18: ...is for AES in 1 and LED 2 is for AES in 2 Note When in 1 8 mode LED2 is always OFF 1 2 3 4 DIP Switch ON OFF LED 2 LED 1 Channel 1 Status Channel 2 Status Front Panel Alarm Indicator There is also a s...

Страница 19: ...n selected on the control system there is a locate button on the top of the GUI Locate Function in Control System When Locate is selected the status indicator on the GUI and the module LED s will flas...

Страница 20: ...Sample Rate 32kHz to 108kHz independent for each input channel Jitter 0 025 ui Status Monitoring Input present confidence flag AES bi phase coding and parity error Control Remote Control of configurat...

Страница 21: ...on any surface R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 3010 R FR 3010 Rack F...

Страница 22: ...6 155 002 280 Service If you are experiencing problems or have questions concerning your D AD 3220 B MiniModule please contact your local distributor for assistance We offer a fixed cost service excha...

Страница 23: ...acted directly using the information below Address LYNX Technik AG Sandstra e 7 64404 Bickenbach Germany Phone 49 0 6257 938017 Fax 49 0 6257 938025 Website www lynx technik com E Mail info lynx techn...

Страница 24: ...Reference Manual D AD 3220 B Version 1 0 Page 24 This Page is intentionally left blank...

Страница 25: ...Reference Manual D AD 3220 B Version 1 0 Page 25 Notes...

Отзывы: