background image

         C DX 5624 Reference Manual. Rev 2.0 

 

Aperture Correction 

We provide a horizontal aperture corrector for the converted outputs which permits the 
sharpening or softening of the SDTV outputs (a slight roll off in high frequency is a normal 
part of the down conversion filtering process). The checkbox can be used to switch 
aperture ON and OFF. (ON= Default). When set to ON a small preset amount of 
correction is applied to produce a flat frequency response on the outputs. When set to 
OFF all Aperture correction is removed.  
 
The amount of aperture correction is adjustable (from the factory preset)  
range + 30 to -80. Adjustments in the positive direction will sharpen the image and the 
negative direction will soften the image. 
 

SDI output routing 

There are two small radio buttons which can be used to change the SDI digital outputs. 
One selection takes the signal before the down converter and will provide two re-clocked 
outputs of the incoming SDI signal. The other selection (default) provides two converted 
digital outputs. 
 

Output Standard 

The output standard is indicated in green for the analog and digital outputs. 
 

Note 

The down converter will automatically select the correct output standard 
depending on the connected input standard. For example if a 50Hz input signal is 
detected then a 625 PAL output will be provided. Likewise if a 59.94Hz or 60Hz 
input is detected then a NTSC 59.94Hz output will be provided. 
 

Analog Video Tab 

 

 

 
This GUI screen is where you would access all the controls for the analog to digital 
conversion and proc functions 
 

Page 21 of 29 

Содержание C DX 5624

Страница 1: ...any purpose without express written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject...

Страница 2: ...ESSING 8 AUDIO PROCESSING 8 TEST PATTERNS 9 FUNCTIONAL DIAGRAM 9 MODULE LAYOUT 10 CONNECTIONS 11 VIDEO 11 AUDIO 11 INSTALLATION 12 SETTINGS AND CONTROL 13 MULTI FUNCTION SWITCH 13 USING THE LOCAL DISP...

Страница 3: ...ot apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a to repair da...

Страница 4: ...1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested...

Страница 5: ...less observing adequate ESD precautions Please see below ESD Warning This product is static sensitive Please use caution and use preventative measures to prevent static discharge or damage could resul...

Страница 6: ...or HW Revision 03 only older boards do not support this Two serial digital outputs are also provided which can be configured to provide 2 x digital down converted outputs or 2 x re clocked copies of t...

Страница 7: ...ted using the local controls or preset with the optional control system Letterbox This takes the 16 9 aspect ratio of the input HD signal and fits it into the 4 3 SD aspect ratio screen with black bar...

Страница 8: ...ash ram and will survive power cycles and long term storage Note Settings will be written to flash RAM automatically after 10 seconds with no activity This can be observed by the alarm LED flashing ye...

Страница 9: ...al PLL EQ and Full field Blue blue screen Test patterns are provided on the analog and Digital video outputs in the selected format If configured to pass the input HDTV to the digital outputs then bot...

Страница 10: ...rence Manual Rev 2 0 Module Layout Module Front Panel Module Rear Termination Panel CardModule Layout Cooling Fan Note Cooling fan operation is monitored and alarmed when using the LYNX control system...

Страница 11: ...or both Unbalanced AES3id and Balanced AES3 connections Unbalanced connections are made using the two BNC connectors AES 1 and AES2 Balanced connections are made via the 25 pin SubD connector Connecti...

Страница 12: ...below NOTE Observe static precautions when handling card Please see ESD warnings on Page 5 Each Card Module is supplied with a rear connection panel and two mounting screws Please follow the followin...

Страница 13: ...unction Switch Side Front CDX 5624 LED 1 SDI Status Multi Function Switch Matrix Display LED 1 AES Status LED 3 Alarm Multi Function Switch The CardModule is equipped with a multi function switch loca...

Страница 14: ...available settings for any menu item in the table supplied does not represent the order the settings will actually be displayed If left unattended the menu will default to the root display after a pre...

Страница 15: ...Filter 0 65 0 65MHz 1 00 1 00MHz 1 30 1 30MHz 2 00 2 0MHz 3 00 3 0MHz CIF CIF Filter QCIF QCIF filter back back LIM Luma undershoot Limiter OFF Off 1 5 1 5 IRE 6 0 6 0 IRE 11 11 IRE back LINE Active...

Страница 16: ...Channel Select GAIN Gain Adjustment CH1 CH2 CH12 CH3 CH4 CH34 CH12 Channels 1 and 2 Ganged together CH 34 Channels 3 and 4 Ganged together 3 0 3 0 MUTE Mute Audio OFF ON back DEMP Audio De emphasis OF...

Страница 17: ...ndicators that serve as alarm and status indication for the module Function is described below SDI Status LED 1 AES Status LED 2 Alarm LED 3 LED Color Indication Green Input 1 SDI Present Red Input Mi...

Страница 18: ...possible for the C DX 5624 CardModule The above screenshot shows the complete module GUI The Device info area contains information about the module including name and firmware revision If used as par...

Страница 19: ...and checkboxes Input Detection On the left the SDI input is detected and the format displayed on screen in green Deembedder The first stage is the audio deembedder The four audio groups are represent...

Страница 20: ...to configure the standard of the internal test signal This can be preset to follow the last input standard connected or forced into any independent standard which is useful if using the module as a t...

Страница 21: ...ative direction will soften the image SDI output routing There are two small radio buttons which can be used to change the SDI digital outputs One selection takes the signal before the down converter...

Страница 22: ...ode Add pedestal when selected will add a 7 5IRE pedestal to the analog outputs PAL M will configure the NTSC outputs to the PAL M standard PAL Output Options There is one selection possible when in P...

Страница 23: ...to configure the filter response for the chrominance portion of the signal The drop down box provides the following selections and the filter characteristics are shown for each 3 0 MHz Default 3 0 MHz...

Страница 24: ...the vertical interval blanked Chrominance off When selected this will turn off the chrominance part of the signal and a luminance only black and white image will be provided Burst off When in composit...

Страница 25: ...double buffers the video signal so that any changes made to the module settings over the remote Ic2 interface occurs in the vertical blanking interval Analog Video Gain Tab This GUI screen provides a...

Страница 26: ...justment of various video parameters These settings apply only for the analog video outputs Settings provided are Luma Level U Level V Level Black Level Sharpness Hue To operate a slider it must be en...

Страница 27: ...n selected this will apply deemphasis to the audio output Mute When selected this will mute the analog audio outputs silence Gain Adjustments Adjustable gain is provided via two sliders one for the ri...

Страница 28: ...Outputs Modes 3 x CVBS or 1 x CVBS YC or 1 x YUV Return Loss 35dB 5 75MHz Signal to Noise 60dB D A Conversion 10 bits and 54 MHz 4x over sampling Digital Audio Outputs Signal 4 x AES3 balanced Impeda...

Страница 29: ...available from our website Please do not return products to LYNX without an RMA Please contact your authorized dealer or reseller for more details More detailed product information and product update...

Отзывы: