background image

FinishLynx G

OLD 

P

ACKAGE

 Quick Start Guide – for Vision cameras 

Page 8 

16.

 

Go to 

File|Open

 and select the Boys3000 from the Lynx 

directory 

17.

 

The top 3 (Max) results should page through the display 
and change the information displayed every 5 seconds 
(Time) 

Step 16: 

 

Automatic Capture Module (ACM) 
Setup and Operation 

A: Using ACM to Stop Running Time

 

The following information will help to setup the ACM feature 
for stopping or pausing the running time with each race. 

1.

 

In the Hardware Control window, click on the 

Camera 

Settings

 (blue circle with white “I” in upper left). 

2.

 

In the Camera Settings, click on the 

Inputs 

tab and set 

Photo Eye

 to 

Internal

.  

3.

 

Next, click on the 

Capture

 tab and set 

Capture Method

 to 

Automatic

4.

 

Click 

OK

 and close the Camera Settings. 

5.

 

Click on 

File | Options

 and the select the 

Scoreboard

 tab. 

6.

 

Confirm that the scoreboard is setup properly as show 
above. 

B: Manually Control ACM: 

1.

 

Click on 

File|New

 to create a new blank event or click on 

the 

Create New Blank Event 

button in the upper left. 

2.

 

In the Event Window make sure there is an 

A

 for Armed 

and 

S

 for Scoreboard and it says 

Armed

 to the right of the 

race clock (when using ACM the C for capture will not 
show until capture is enabled). 

3.

 

Create a start for the event and confirm that the running 
time is showing on the uTabLED display. 

4.

 

Click the Capture icon to enable capture and then hit the 

Ctrl+F

 keys and it will say Finishing to the right of the race 

clock (click on Scoreboard Menu for shortcut keys). 

5.

 

Have someone run through the finish line and the camera 
should capture image and the running time should stop 
and display the time to the hundredths. 

NOTE

:

 In multi-lap races you can use 

Alt+P

 to pause the 

running time as competitors pass in front of the camera. 

C: Automatic ACM Setting: 

NOTE

: Autobreak settings will occur automatically for every 

race so play with your settings to make sure it fits the way you 
want to handle each race, even multi-lap races. 

1.

 

Go to 

File|Options

 and select the Scoreboard tab. 

2.

 

Under Running Time on the third line is 

Autobreak

, these 

settings allow it to occur automatically. 

3.

 

Selecting 

Finish

 and 

If Capturing

 will cause the running 

time to stop when ACM is on and the competitors cross 
the finish line. 

4.

 

Selecting 

Pause

 but NOT 

If Capturing

 will cause the 

running time to Pause each time competitors cross the 
finish line in multi-lap races when capture is not enabled. 

Step 17: 

 

Use FinishLynx with LynxPad Data 

1.

 

In FinishLynx, click 

 to load the schedule of events 

from LynxPad.  The 

Go To Event

 dialog appears.   

2.

 

Click the 

Load Schedule

 button once.  Click the drop-down 

list under the 

Load Schedule

 button.  A list of events 

appears.  Click to select the “

110 Meter Hurdles Men (9, 

3, 1)

” event in the list, and then click 

Ok

.  The first heat of 

the third round of the men’s 110m hurdles opens on the 
FinishLynx screen. 

3.

 

Either use a starting gun, or knock the sensor sharlpy 
against a hard object - this simulates the firing of the 
starting gun and starts the yellow FinishLynx timer. 

4.

 

Have your assistant run through the finish line while you 
press down and hold the red capture button to capture 
the image.  Release the button as soon as he/she has run 
completely through the finish line. 

5.

 

Practice evaluating the image by following the same steps 
you followed earlier in Step 3:  

6.

 

Click 

File

 | 

Save

 to save the race to the 

Practice 

competition

 directory. 

7.

 

Crop space between competitors in your FinishLynx image 
by right-clicking and drawing a box around the unwanted 
space.  Release the mouse button and select 

Crop

 from 

the dialog that appears. 

8.

 

(Optional)

 Print the results and a portion of the FinishLynx 

image by right-clicking on the image and drawing a box 
around the portion you want to appear in your printout. 
For example, the first place finisher or a close finish 
between two competitors.  Click 

Ok

 and then select the 

printer from the 

Print

 dialog to send the image with 

results to the printer.   

9.

 

Click 

File

 | 

Close

 

window

 and then click 

Yes

 to save 

changes you made to the FinishLynx image when you 
cropped it. 

10.

 

In LynxPad, click to highlight 

Men 110 Meter Hurdles

 in 

the 

Events

 window.  The start list appears in the 

Heats

 

window. 

11.

 

Still in LynxPad, click 

Competition

 | 

Refresh All Results

.  

The results from the race you just evaluated appear in 
LynxPad.  

 

This completes the 

FinishLynx Gold System Quick Start Guide

.   

 
Looking for more resources? Visit our YouTube 
Channel for setup and support videos: 

https://www.youtube.com/user/LynxSystemDevelopers/

 

timer 

Содержание FinishLynx Gold

Страница 1: ...FinishLynx GOLD PACKAGE Quick Start Guide for Vision cameras Page 1 FINISHLYNX GOLD PACKAGE QUICK START GUIDE FOR ETHERLYNX VISION CAMERAS Updated April 2017...

Страница 2: ...10BT 25 CS Mount 2 8 10mm P Iris lens CS2810P 1 x 100 ft Ethernet cable C10BT 100 CS Mount to C Mount Adapter MCS C Capture button and USB Serial adapter 1A205 Remote positioner 2L102 Button splitter...

Страница 3: ...reen to install LynxPad When prompted enter the serial number found on your Lynx USB Flash Drive Note You should Right Click on the installer and select Run as Administrator to install LynxPad if you...

Страница 4: ...tripod Setup the tripod in line with the finish line preferably on the infield and approximately 10 feet back Note Minimum recommended camera distance from track is 8 feet at this distance you may no...

Страница 5: ...e Button 7 Depending on the distance between the scoreboard and your computer or camera connect the scoreboard serial cable either to the Serial Port on your Connection box or to the other 9 pin seria...

Страница 6: ...ra s b Image Orientation select the correct orientation for finish infield would be Left orientation c Identify By select Lane for track competition d Lanes enter the number of lanes on the track the...

Страница 7: ...of the MicroTab LED display 2 Plug the DB9 connection into the Connection Box for the FinishLynx camera or a COM port on the computer USB to Serial Adapter for laptops 3 Open the FinishLynx software...

Страница 8: ...l cause the running time to stop when ACM is on and the competitors cross the finish line 4 Selecting Pause but NOT If Capturing will cause the running time to Pause each time competitors cross the fi...

Отзывы: