background image

FinishLynx G

OLD 

P

ACKAGE

 Quick Start Guide – for Vision cameras 

Page 7 

b.

 

Capture a small amount of image containing a white 
object, such as a 

person

 wearing a white t-shirt. 

c.

 

Right-click and draw a box around a small amount of 
the 

white

 image.  You may need to zoom in to the 

image to do this. 

d.

 

Click 

Image

 from the Menu bar and select

 Set white

 

balance

Step 11: 

 

Create a shared directory for 
FinishLynx and LynxPad 

1.

 

Right-click on your computer desktop and select 

New 

Folder

.  When the 

New Folder

 appears, change the name 

to 

Practice competition

2.

 

In FinishLynx, click 

File

 | 

Options…

.  Click the 

Browse

 

button on the 

Event Directory:

 and navigate to the 

Practice competition 

directory

 

you just created.  Then, 

click 

Ok

3.

 

Still in FinishLynx, click 

File

 | 

Options…

 and click the 

Database

 tab.  Click the 

Browse…

 button next to the 

Output Directory:

 and navigate to the 

Practice 

competition

 directory.  Then, click 

Ok

4.

 

Now, start LynxPad by clicking the Windows 

Start

 button 

and then 

All Programs

 | 

LynxPad

.   

5.

 

Click 

File

 | 

Options…

 and 

uncheck

 the 

Load Existing 

Results on Program Start 

box.  Then, click 

Ok

6.

 

Open the sample competition by clicking 

File |

 

Open.

  

Navigate to 

C:\LynxPadData\Sample

 and then double-

click the 

lynx.cmp

 file.  A practice competition opens on 

the screen. 

7.

 

Still in LynxPad, click 

File

 | 

Options…

.  Click the 

Browse

 

button next to the 

Directory:

  text field.  Navigate to the 

Practice competition

 

file you created earlier.  Select it and 

click 

Ok

.  Click 

Apply

 and then click 

Ok

 again.     

8.

 

Still in LynxPad, click 

File

 | 

Save as…

 and navigate to the 

Practice competition 

folder.  Then, click 

Ok

.  Now, 

FinishLynx can get start lists created in LynxPad, and 
LynxPad can import results generated by FinishLynx. 

Step 12: 

 

Mount & Install IdentiLynx camera 

Follow the instructions on the separate IdentiLynx Quick Start 
Guide 

Step 13: 

 

Setup RadioLynx wireless start 

Follow the instructions on the separate RadioLynx Quick Start 
Guide 

Step 14: 

 

Setup Scoreboard 

1.

 

Plug the serial cable into Serial 1 on the side of the 
MicroTab LED display. 

2.

 

Plug the DB9 connection into the Connection Box for the 
FinishLynx camera or a COM port on the computer (USB 
to Serial Adapter for laptops). 

3.

 

Open the FinishLynx software.  

4.

 

Power on the MicroTabLED display. 

NOTE:

 if using a USB to Serial Adapter, plug it into the USB 

port before booting FinishLynx software. 

Step 15: 

 

Scoreboard Option Settings 

1.

 

Go to 

File|Options

 and select the 

Scoreboard

 tab from 

the options window.  

2.

 

Click on 

New

 to create a scoreboard or new scoreboard 

listing in the status window. 

3.

 

Click on the dropdown for 

Script

 and select the 

uTabLED.lss

 from the list (alphabetical listing) 

4.

 

In the text box for 

Name

, type in 

uTab LED

 (or anything to 

help you identify each board if there are multiple listings). 

5.

 

Code Set should be left as Single Byte 

6.

 

Click the dropdown for Serial Port and choose the 
appropriate COM # from the list. If using the C-Box, the 
camera must be booted for the selection to be available. 

NOTE

there may be multiple selections for COM port so check 

Device Manager on the computer and find out which number 
is assigned – or use trial and error. 

7.

 

Verify that the serial port settings are:   

a.

 

baud – 

1200

;  

b.

 

data bits – 

8

;  

c.

 

parity – 

None

;  

d.

 

stop bits 

1.0

 

8.

 

For 

Running Time

 click the radio button for 

Auto

 and the 

other settings for running time can be left with the 
default. 

9.

 

For 

Results

 select the following settings: 

a.

 

Auto

 

b.

 

Always

 

send

 

place

 

c.

 

Paging

 

d.

 

Size

 

set

 to 

1

 

e.

 

Max

 

should

 be limited (

3-8

 results) 

f.

 

Time

 – how long info displays 

10.

 

Click 

OK

 to close the Options window. 

11.

 

Close the FinishLynx program and re-start the software.  If 
the camera was booted, it will come back when you re-
start the software. 

12.

 

Go to 

File|Options

 and select the Scoreboard tab and 

verify that status now says running.  

13.

 

Click 

OK

 to close the Options window 

14.

 

Using the menu bar at the top of the FinishLynx software, 
click on 

Scoreboard

 and then select 

Show Time of Day

.  A 

check mark should appear next to Show Time of Day and 
the time should now display on the board. 

15.

 

Click on Scoreboard again from the Menu Bar and then 
select Show Time of Day again and it will remove the 
check mark and stop the output to the scoreboard. 

Содержание FinishLynx Gold

Страница 1: ...FinishLynx GOLD PACKAGE Quick Start Guide for Vision cameras Page 1 FINISHLYNX GOLD PACKAGE QUICK START GUIDE FOR ETHERLYNX VISION CAMERAS Updated April 2017...

Страница 2: ...10BT 25 CS Mount 2 8 10mm P Iris lens CS2810P 1 x 100 ft Ethernet cable C10BT 100 CS Mount to C Mount Adapter MCS C Capture button and USB Serial adapter 1A205 Remote positioner 2L102 Button splitter...

Страница 3: ...reen to install LynxPad When prompted enter the serial number found on your Lynx USB Flash Drive Note You should Right Click on the installer and select Run as Administrator to install LynxPad if you...

Страница 4: ...tripod Setup the tripod in line with the finish line preferably on the infield and approximately 10 feet back Note Minimum recommended camera distance from track is 8 feet at this distance you may no...

Страница 5: ...e Button 7 Depending on the distance between the scoreboard and your computer or camera connect the scoreboard serial cable either to the Serial Port on your Connection box or to the other 9 pin seria...

Страница 6: ...ra s b Image Orientation select the correct orientation for finish infield would be Left orientation c Identify By select Lane for track competition d Lanes enter the number of lanes on the track the...

Страница 7: ...of the MicroTab LED display 2 Plug the DB9 connection into the Connection Box for the FinishLynx camera or a COM port on the computer USB to Serial Adapter for laptops 3 Open the FinishLynx software...

Страница 8: ...l cause the running time to stop when ACM is on and the competitors cross the finish line 4 Selecting Pause but NOT If Capturing will cause the running time to Pause each time competitors cross the fi...