27
2.7.2. Microphone setting
There are five function keys on microphone unit:
MENU/BACK,
(LEFT), (RIGHT),
(UP), (DOWN).
Press
MENU/BACK
to enter setting, and then select the setting items by
LEFT
&
RIGHT
a.
LCD CONTRAST: 43-63 Levels, default setting is 55.
b.
LIGHT TIME: 1-5 Seconds, default setting is 3 seconds
c.
Microphone ID setting:
1) Turn off the microphone first before setting ID.
2) ID number should be set from [001] to [128]
[Example] If you have 50 units, their ID numbers should be set from [001] to [050],
if any units have the same ID number, the system will not work properly.
3) ID number of chairman microphone should be [001], one system only allowed one
piece chairman microphone
4) Setting method:
Press
MENU/BACK
, and turn on the microphone with POWER key at the same time,
microphone LCD will display ID setting interface. User can set the microphone ID
number by
UP
&
DOWN
, please press
MENU/BACK
after setting the ID number,
microphone will save the setting and restart again.
d.
Microphone DCH (Data Channel) setting:
1) Turn off the microphone first before setting DCH
2) DCH should be same as main unit DCH.
3) Microphone default setting is CHANNEL 1
4) Setting method:
Press
MENU/BACK
, and turn on the microphone with POWER key at the same time,
microphone LCD will display ID setting interface, press
RIGHT
key to enter DATA
CHANNEL setting interface. User can set the microphone data channel by
UP
&
DOWN
key , please press
MENU/BACK
after setting the data channel, microphone
will save the setting and restart again.