background image

 

 

 

 

OWNER'S MANUAL 

 

 

 

INFRARED WIRELESS CONFERENCE 

SYSTEM   

 

 

 

 

 

 

 

 

 

 

 

 

H-8610 SERIES 

 

Version: REV1.0 (2011) 

 

Содержание H-8510

Страница 1: ...OWNER S MANUAL INFRARED WIRELESS CONFERENCE SYSTEM H 8610 SERIES Version REV1 0 2011 ...

Страница 2: ...meter of distributor 8 1 5 Infrared receiver unit H 8610R 9 1 5 1 Picture of the actual object 9 1 5 2 Features of receiver unit 9 1 5 3 Schematic diagram of receiver unit 9 1 5 4 Parameter of receiver unit 9 1 6 Battery charger H 8610CG 10 1 6 1 Picture of the actual object 10 1 6 2 Features of battery charger 10 1 6 3 Schematic diagram of battery charger 10 1 6 4 Parameter of battery charger 11 ...

Страница 3: ...video equipments 19 2 4 5 IR main unit to external antenna 20 2 5 Installation of IR receiver unit 20 2 5 1 IR Receiver operating range 20 2 5 2 Installation diagram of IR receiver unit 22 2 5 3 Wiring between IR receiver unit and main unit when using distributors 23 2 5 4 Caution item 24 2 6 Installation of IR microphone unit 24 2 6 1 Mounting and dismounting the battery 24 2 6 2 Mounting and dis...

Страница 4: ... eliminates the need of connecting the conference units Installation can be done quick and smart without cumbersome arrangements d Fully functions Discuss Video tracking voting support FIFO 1 2 3 Limit 1 2 3 and chairman only mode microphones in one system up to 128 units e Microphones can be operated on either their built in rechargeable lithium ion batteries or AC power supply Battery life appro...

Страница 5: ...y 9 Audio Level indicator first channel is for chairman microphone others are for delegate microphone 10 Camera video in BNC interface VIDEO IN 1 11 Camera data control interface RS485 RS422 12 Camera video in BNC interface VIDEO IN 2 13 Camera data control interface RS485 RS422 14 Camera video in BNC interface VIDEO IN 3 15 Camera data control interface RS485 RS422 16 Camera video in BNC interfac...

Страница 6: ...o 70dB Audio channel T H D 0 5 Transmission method Wireless Data channel 14 Frequency Range 901MHz 927MHz Modulation method FSK Receiving sensitivity 80dBM Transmission consumption 10dBM Communication rate 100KBPS Data control channel Signal covering range Radius 100M Power supply AC110V 240V 50Hz 60Hz Consumption Rating 10W Operating temperature range 0 40 degree Dimensions 484 377 85mm System N ...

Страница 7: ...conds option i Microphone will shut off the power in 60 seconds to save battery power if system communication is error j LCD will display IR Signal Weak if the IR signal is weak when microphone working 1 3 3 Features of infrared chairman microphone H 8610c Including the functions of the delegate unit chairman unit has other following functions a Chairman microphone can turn on any time b In one sy...

Страница 8: ...rared Audio channel 4 Carrier frequency band 6MHz 8MHz Modulation method FM Infrared radiator consumption 10dBM Mic sensitivity 44dB 2dB Frequency response 100Hz 10KHz S N Ratio 70dB T H D 0 5 Audio channel Reference sound receiving 10 30cm Transmission method Wireless Data channel 14 Frequency Range 901MHz 927MHz Modulation method FSK Receiving sensitivity 85dBM Transmission consumption 10dBM Dat...

Страница 9: ...hielded function 1 4 3 Schematic diagram of distributor 1 BNC terminal Connector for the BNC coaxial cable connection 2 Mounting and fixing holes Holes for mounting distributor body 1 4 4 Parameter of distributor Items Parameter Carrier frequency band 6MHz 8MHz Insertion loss computation 1dBM Input Output Impedance 50Ω Input terminal 2 Output terminal 1 Terminal type BNC Dimensions 80 65 20mm N W ...

Страница 10: ...er LED This Led will light when the main unit turns on after wiring 2 IR lens 3 BNC connector A for wall installation 4 BNC connector B for ceiling installation 5 BNC connector switch A B Please select correct position according to the installation 1 5 4 Parameter of infrared conference system receiver unit Items Parameter Carrier frequency band 6MHz 8MHz Power supply DC12V from Main unit Rated cu...

Страница 11: ...ttery per charging c Intelligent charging management electro circuit to protect the LIP battery d Equipped with extendible handle and pulley easy for moving 1 6 3 Schematic diagram of battery charger 1 Pulley 2 Extendible handle 3 Charging status indicator LED 4 Battery holder 5 Power indicator 6 Power on off switch 7 AC adapter jack AC110V 220V 50Hz 60Hz ...

Страница 12: ... 700mA Charging time About 8 10 hours Charging status Red LED flashing Charging Green LED Full Operating temperature range 0 40 degree Dimensions 620 370 210mm N W 10 74kg 1 7 Infrared conference system external antenna H 8610AT 1 7 1 Picture of the actual object 1 7 2 Schematic diagram of external antenna 1 Antenna 2 Signal BNC connector 3 Mounting bracket ...

Страница 13: ...e light weight High capacity ratio b Improved safety more resistant to overcharge less change for electrolyte leakage c High Capability Have nearly double the capacity with half the weight of NiCad or NiMH battery packs d Easy to install 1 8 3 Schematic diagram of LIP battery 1 Battery detach lock button 2 Negative 3 Positive 1 8 4 Parameter of LIP battery Items Parameter Rated voltage DC12V Disch...

Страница 14: ...ual object 1 9 2 Schematic diagram of AC power adapter 1 AC Power plug 2 Transformer 3 DC plug 1 9 3 Parameter of AC power adapter Items Parameter Input voltage AC110V 220V 50Hz 60Hz Output voltage DC 18V 600mA Dimensions 98 70 55mm only transformer N W 750g ...

Страница 15: ...14 2 System installation 2 1 System connection diagram ...

Страница 16: ...e of the units may result in electric shock Do not expose the units to any strong shock Do not exposé the units to direct sunlight heat from heating appliances high temperatures or dust Do not expose the units to high humidity or moisture Water that accidentally enters the inside of the units may result in electric shock malfunction or fire Do not touch the power cables or plugs with wet band Main...

Страница 17: ...unit Do not use it for other applications Use only the designated battery charger If the battery leaks and the liquid contacts your skin or clothing immediately flush with clean water If the battery leaks and the liquid contacts your eyes immediately wash thoroughly with clean water and seek medical assistance Do not throw the battery into fire or overheat it Doing so may result in a fire Do not d...

Страница 18: ...oned about is the distance from ceiling to desk 2 3 3 Check quantity of receiver unit Please check the ceiling height and coverage area of one receiver unit with above information 2 3 2 to make sure real coverage area can receive the signal well Calculate formula A Receiver quantity B Real coverage area C Coverage area of one receiver unit A B C Ceiling height Coverage area receiver unit 2 5 m 20 ...

Страница 19: ... 1 IR main unit installation a Put on the table or install in 19 inch frame b Please keep away from high power and strong radiation equipments or it may influence the equipment performance c Use it in a well ventilated area 2 4 2 IR main unit to IR receiver unit Connect one side of coaxial cable to the BNC terminal RF A B of IR main unit the other side connects to the BNC terminal of IR receiver u...

Страница 20: ... audio cable b Dual track Please connect LINE OUT L R interface of IR main unit to input interface of sound equipment by RCA audio cable 2 4 4 IR main unit to video equipments Please connect camera video out to video in 1 4 BNC interface of the main unit camera id should from 1 4 Camera data control cable can connect to the corresponding data interface independently or in parallel connection it me...

Страница 21: ...onnect to the ANT interface of IR main unit rear panel directly If the distance is far or have some obstruct between them please connect external antenna to IR main unit 2 5 Installation of IR receiver unit 2 5 1 IR receiver operating range a Infrared operating distance is approximately 10 m and the receiving range is approximately 150 degrees b Infrared operating range of the IR receiver unit and...

Страница 22: ...eight of the IR receiver unit from the floor M D the distance between IR receiver unit M Infrared operating distance is approximately 10 m and the receiving range is approximately 150 degrees Be sure to overlap the infrared operating areas by approximately 2M Be careful not to place the units behind users or objects When IR receiver units are installed on the side walls take care not to install th...

Страница 23: ...mounting hook position mount the IR receiver unit on the mounting bracket ii Then rotate the IR receiver unit clockwise to fasten it securely Be sure that the IR receiver unit is securely fastened 2 5 3 Wiring between IR receiver unit and main unit when using distributors If the input signals of each IR receiver unit are not in the same phase the receiving level may decrease To match the signal ph...

Страница 24: ...or transmit IR signal and IR receiver power DC12V please make sure the circuit not shorted between IR signal and power when install the IR receiver or it will burned out the fuse 0 5A of IR receiver unit on the rear panel of IR main unit a Please stripping the coaxial cable 50Ω outer shield net and insulating layer with above sketch map b Insert the wire and connect to the center pin soldering it ...

Страница 25: ...ystal DLP OHP incandescent bulbs Mercury lamp halogen lamps and inverter fluorescent lamps Plasma displays Infrared devices such as the remote control infrared microphones and infrared LAN Dimmer controls Digital equipment like the digital power amplifier and cable wiring to this such as speaker output wiring of the digital power amplifier Up to 12 IR receiver units can be installed of each channe...

Страница 26: ...to fasten it securely b Dismounting microphone Rotate the microphone counterclockwise then pull the microphone upward to dismounting 2 6 3 Microphone operating range and distance 2 6 4 Examples of square arrangements Example Conference room area 286 m2 Real coverage area 18 10 180 m2 Height of the ceiling 3 m Please contact us if you need more detailed information during your installation ...

Страница 27: ...rface User can set the levels by LEFT RIGHT System will save and keep the last setting automatically Press MENU again to enter project setting c Project setting 1 SYSTEM MIC 1 128 we strongly commend set the system number same as real number Microphone responding time will influenced by system number setting User can set the system microphone number by LEFT RIGHT 2 DCH Data Channel 1 14 default se...

Страница 28: ...chairman microphone 4 Setting method Press MENU BACK and turn on the microphone with POWER key at the same time microphone LCD will display ID setting interface User can set the microphone ID number by UP DOWN please press MENU BACK after setting the ID number microphone will save the setting and restart again d Microphone DCH Data Channel setting 1 Turn off the microphone first before setting DCH...

Страница 29: ...se setting 1 Turn off the microphone first before setting 2 Setting method Press MENU BACK and turn on the microphone with POWER key at the same time microphone LCD will display ID setting interface press RIGHT key three times to enter auto close setting interface User can set microphone auto close function by UP DOWN key please press MENU BACK after setting microphone will save the setting and re...

Страница 30: ...apacity full Battery capacity about 60 Battery capacity about 30 Battery capacity less than 10 Battery charged by DC power and microphone was powered by external DC power Battery full microphone was powered by external DC power 2 Signal level Signal disconnect Signal very weak Signal weak Signal good Signal strong 3 Microphone ON OFF state 4 Current microphone ID number 5 Current microphone data c...

Страница 31: ...lay in the software and sub screen Operator can set in software voting results by first key press last key press 2 9 3 Elect There are five buttons on the microphone unit for electing Candidate 1 2 3 4 5 After election starts delegate can press the corresponding button according to their decision The delegate can re elect before the election finishing if they want to change their elect the electio...

Страница 32: ...en the main unit and the IR receiver units properly Operating time of the microphone unit battery is short The battery is dying 1 Purchase a new battery The microphone unit battery can not be charged The charging lamp does not light The charging lamp is flashing Charging does not complete after 12 hours Are the charging terminals dirty Has the battery been left for a long time after charging Can o...

Отзывы: