Connecting an AC/DC Power Supply
Connecting an AC/DC Power Supply
Note: The LXE-approved AC Power Supply and Adapter Cable are only intended for use in a 25ºC (77ºF) maximum
ambient temperature environment.
1. AC Input Cable (US only)
2. DC Output Cable
3. To DC Output Cable (see above)
4. To VX3X
In North America, this unit is intended for use with a UL Listed ITE power supply with output rated 12 – 80 VDC, minimum
15W75W . Outside North America, this unit is intended for use with an IEC certified ITE power supply with output rated 12 – 80
VDC, minimum 15W75W .
The external power supply may be connected to either a 120V, 60Hz supply or, outside North America, to a 230V, 50Hz
supply, using the appropriate detachable cordset. In all cases, connect to a properly grounded source of supply provided with
maximum 15 Amp overcurrent protection (10 Amp for 230V circuits).
1. Turn the VX3X off.
2. Connect the detachable cordset provided by LXE (US only, all others must provide their own cable) to the external
power supply (IEC 320 connector).
3. Plug cordset into appropriate, grounded, electrical supply receptacle (AC mains).
4. Connect the DC Output Cable end to the corresponding connector on the Adapter Cable.
5. Turn the VX3X on.
E-EQ-VX3XOGWW-G-ARC [ 9 ] VX3X User Guide