LW MEASUREMENTS LC-VS Скачать руководство пользователя страница 15

15 

Rev 2, 1.14.2016 

  Press 

the “hold” key, display will show CAP, press the “hold” key again, display 

shows CALu=, then press the 

“Unit” key to select unit of measurement kg. or lb., 

a triangle icon will display to indicate kg. Or lb., press 

the “Hold” key to confirm, it 

will show CALu= again. 

  Press the 

“hold” key again, the display will show CAL, press the “Unit” key to set 

calibration weight, display will show XXXXX with a flashing digit, press 

the “Unit” 

key to move the flashing digit to right, press 

the “Zero” key to increase the value 

of the flashing digit, press 

the “Hold” key to confirm, it will show CAL again. (We 

recommend a calibration weight at least 2/3 of the full capacity to get an accurate 
weighing) 

  Press 

the “print” key, the display will show CAL and then the AD value, press the 

“Unit” key when the stable indicator displayed, it will show the flashing calibration 
weight. 

  Place the known test weight on the platform, press the 

“Unit” key after stable 

indicator displayed, it will show ------, and then the AD value, the calibration is 
complete. 

  Turn off the scale, remove the test weight from the platform. 

  Press 

the “on/off” key to turn the scale on to test if the weighing is accurate, if not, 

repeat above steps.  

Maintenance and service 

 

The weighing machine must be treated carefully and cleaned regularly. It is a precision 
instrument. 

 

 

 
For  maintenance-work,  the  balance  must  be  disconnected  from  the  power  supply 
(remove  power  adapter  plug  from  socket).  Also  ensure  that  the  balance  cannot  be 
connected to the power supply during the work by a third party. 
 
Make sure that no liquid spills into the scale while performing maintenance work. If 
liquid is spilled on the scale, it must be inspected by a service technician. 
 
Regularly perform maintenance to the weighing pan and the weighing pan holder by 
removing any dirt or dust from under the weighing pan and on the weighing scale 
housing. Use a soft brush or a soft, lint-free cloth, moistened with a mild soap solution.  

 

 
 
Never use solvents, acids, alkalis, paint thinners, scouring powders or other aggressive 
or corrosive chemicals for cleaning; these substances can cause damage to the 
surfaces of the scale housing.

 

 

 

 

Содержание LC-VS

Страница 1: ...Professional Weighing Equipment VET Scales LVS LVS XL LC VS Operation Manual...

Страница 2: ...r Service 4 Introduction 4 Safety 5 Weight Scale 6 Functions 7 Features 8 Application Conformity 8 RS232 Data 9 Getting Started 10 Delivery 10 Assembly Installation 11 Application Menu 12 Program Opti...

Страница 3: ...aration refers conforms to the following standards Electronic scale Vet Scales series Mark applied EU Directive Standards 2004 108 EC EN 61326 1 2006 Signature Boon Lim R D Manager Date 14 11 2012 LW...

Страница 4: ...ou should know about these Operating Instructions Tree Professional Weighing Equipment products are simple to operate Nevertheless you should read through these operating instructions in their entiret...

Страница 5: ...adapter If there should be any reason to believe that it is no longer safe to operate the scale it should be immediately unplugged from the electricity supply pull out power adapter and secured agains...

Страница 6: ...4 2016 Weight Scale Construction Functions The weighing scale consists of the following parts The Scale body 1 The indicator 2 Rubber Mat 3 The adapter 4 Operation manual Figure 2 1 Your weighing mach...

Страница 7: ...rton LVS 700 LC VS 400 117 x 63 x 13 cm3 LVS XL 700 131 x 69 x 13 cm3 Operating Temp 0 40 32 104 Power source 6 x AA dry cells not included or AC DC Adapter 9V DC 100mA Metric weight unit version Mode...

Страница 8: ...devices produced by other manufacturers the appropriate regulations for the safe use of the relevant attachments and their application in accordance with instructions must be observed The weighing sca...

Страница 9: ...600 Data Bit 8 Parity Bit None Stop Bit 1 Data Format ASCII 3 Transmission Information Format 20 Byte blank 20H 1 2 3 4 13 14 18 19 20 W P DATA UNIT CR LF W Start of Data Transmission 57H 3AH P Polari...

Страница 10: ...stored for a couple hours and kept in its box in a dry room at normal temperature so that no condensation settles on the unit when opening the box Check the scale immediately after unpacking for any e...

Страница 11: ...ge If the operating voltage is not the same as the mains voltage the power adapter must not be connected to the mains socket and contact customer service Placement of Scale The location in which the s...

Страница 12: ...HOLD key is to store the weight value The UNIT key is to toggle different weighing units The ZERO key Zero feature if load weight below 4 of full capacity Tare feature if load weight is between 4 to...

Страница 13: ...on the Scale the display will show A ON or A OFF Press UNIT key display will show L ON L OFF or L AU press ZERO key to select back light On Off or Au auto Setting power on mode Press and hold the Hold...

Страница 14: ...ime is chosen Press on off key twice to return to normal operation Hold function Press the on off key to turn on the scale place the item on the platform Wait for the readings to stabilize press the H...

Страница 15: ...ow and then the AD value the calibration is complete Turn off the scale remove the test weight from the platform Press the on off key to turn the scale on to test if the weighing is accurate if not re...

Страница 16: ...purchase After 30 days expire the customer is responsible for shipping the product back to us After the product is received we will inspect it and as necessary we will repair or replace and will ship...

Отзывы: