14
Rev 2, 1.14.2016
*** This is the anti-shock range 50d, 100d, 200d or 400d. The smaller division range is
suitable for smaller animals, the larger division range for larger animals
Press the
“Hold” key again, display will show Ani. Fd, press the “unit” key to enter,
press the
“Zero” key to select filter range between 0.5, 3, 5 and 10, press HOLD
key to confirm.
*** This is the filter range, 0.5d, 3d, 5d or 10d that the scale displays, for example, if we
use LVS 700lb x 0.2lb for weighing a 300lb cow, if we set it to be 0.5d, then the scale
will show 299.8lb, 300lb, 300.2lb..., if we set it to be 3d, then the scale will show 299.4lb,
300lb, 300.6lb... 0.5d can get much accurate weighing, but it won
’t be as stable; 10d will
not obtain such an accurate weighing result, but it will be much more stable.
Press the
“Hold” key again, the display will show Ani. Ft, press the “Unit” key to
enter, then press
the “Zero” key to select filter time between 1, 2, 3 and 4, press
the “hold” key to confirm.
*** This is the filter time, 1s, 2s, 3s or 4s that will take to display the weighing. Weighing
will be more accurate if the user chooses 4 second (longer displaying time), but not so
accurate if 1 second (faster displaying time) is chosen.
Press “on/off” key twice to return to normal operation
Hold function
Press
the “on/off” key to turn on the scale, place the item on the platform.
Wait for the readings to stabilize, press
the Hold” key, the “
.
“ indicator will show
Remove the item from the platform, the readings will still remain on the display
Press
the “Hold” key to quit hold function mode
Calibration
Using an External Calibration Weight
Calibration is generally required when the weighing machine is initially installed or if the
weighing machine is moved to a substantial distance from the original location. 30
minutes of warming up of the scale is always needed before initial calibration.
A reminder when operating our larger capacity scales:
The scales of the LVS / LVS-XL and LC-VS series are calibrated at the factory. Usually
no calibration is necessary unless major inaccuracies are observed. If calibration is
deemed necessary, an appropriate test weight of at least 2/3 of the full capacity of the
scale should be used to obtain accurate weighing.
Calibration procedure:
Press and hold
the “Zero” key and then press the “on/off” key to turn on the scale,
the display will show CAPu=
To set the capacity of the scale; Press the “unit” key to select lbs. or kgs., then
press the “Hold” key to confirm. Press the “Hold” key again and then the “Unit”
key to select 700 capacity, then press “Hold” to confirm.