background image

 

33 

 

RINSE TEMP CONTROL

H

H

W

R

DOOR SWITCH

T1

T2

STOP

START

WSH

PWR

PUMP

CONTACTOR

ON

OFF

POWER

PUMP

MOTOR

BREAKER

PUMP

L1

L2

L3

3

 POWER

FUSE

FUSE

.250 KVA

WSH TEMP CONTROL

24V

FUSE

RNS

RINSE

SOLENOID

T3

T4

FILL

SOLENOID

LOGO

Q

1

Q

2

Q

3

Q

4

Q

5

Q

6

Q

7

I1

I2

I3

I4

I5

I6

I7

I8

I9

I1

0

I1

1

I1

2

Q

8

DISTRIBUTION

LINE

N

BREAKER

RINSE HEAT

BREAKER

WASH HEAT

RINSE

HEATER

9KW

WASH

HEATER

9KW

LOW WATER

CUTOFF

1

4

WASH

SELECTOR

LT

MED

HVY

RINSE

CONTACTOR

HIGH LIMIT

HIGH LIMIT

WASH

CONTACTOR

115V

FAN MOTOR

208

230

460

0

24V

C

FUSE

FAN

RELAY

FAN

CONTROL

SPEED

BLOCK

FILL

Name: Ladder Diagram

FL, PT, CL Electric
124L1101

No.

Mat.

-

Ga.

-

Scale

1:1

08-21-07

M. Elbers

-

Finish
Rev.

-

Pan Washers

LVO Manufacturing, Inc.
808 N 2nd Ave E
Rock Rapids, IA 51246

Phone: (712) 472-3734

 

Содержание PT25

Страница 1: ...LVO Manufacturing Inc PT25 Pan Washer Owner s Manual...

Страница 2: ...Day Air shipping charges for parts with the exception of excessively large or heavy items covered on warranty if the machine is not operational LVO Manufacturing Inc reserves the right to make change...

Страница 3: ...able of Contents 3 PT25 Specifications 4 Electrical Data 5 Warnings Cautions 6 Introduction 7 Installation Instructions 8 Startup Procedures 11 Sequence of Operation 13 Operation of Machine 14 Prevent...

Страница 4: ...lon rinse tank OR steam coil in a 10 gallon rinse tank Recirculating Steam Only Full Load Amps 208 Volt 230 Volt 460 Volt Electric 79 1 71 5 36 8 Gas Injected Steam 54 1 48 9 25 5 Recirculating Steam...

Страница 5: ...9 kW 25 0 22 6 11 3 Rinse Heater one 9 kW 25 0 22 6 11 3 Total Running Current 79 1 71 5 36 8 Electrical Data for models FL14 PT14 FL25 PT25 Gas or Injected Steam 208 Volt 230 Volt 460 Volt Pump Motor...

Страница 6: ...ne Installation Code 2 Instructions should also be posted in a prominent location describing what to do in the event that the smell of gas is detected in the vicinity of the machine This information c...

Страница 7: ...thorough cleaning The machine is equipped with a heating element in the rinse tank to boost the rinse water to a sanitizing 180 F at the inlet to the machine A rinse tank heated with recirculated ste...

Страница 8: ...the washer is uncrated remove the banding that holds the door weight stationary on the back of the machine This will allow the door to open Inside you will find the accessories for the machine Among t...

Страница 9: ...into the flange on the top of the machine before the ductwork is installed The longer 12 adaptor should be placed between the machine and the fan with the shorter 3 adaptor placed into the discharge s...

Страница 10: ...hook up and final adjustments of the burners This is necessary to insure proper inlet and manifold pressure for the gas machines see spec page for gas pressure settings Verify the type of gas supply t...

Страница 11: ...e machine has a door switch and will not operate with the door partially open Step 4 With the machine full of water and with the door closed press the start button and let the machine go through a com...

Страница 12: ...fter turning the machine off before turning it back on If the machine still does not appear to be heating up properly call LVO Manufacturing at 1 800 346 5749 Step 9 Set the rinse pressure by changing...

Страница 13: ...mber indicator light comes on Wash and rinse temp controls are energized Temp controls energize wash and rinse heating systems Door safety switch is energized Stop and Start buttons are energized Star...

Страница 14: ...ated on the drawings later in this manual 7 Once the machine has reached the recommended temperatures detergent should be added to the wash water Detergent should be used according to the recommendati...

Страница 15: ...f the wash cycle the red light will stay on and the 20 sec rest will begin The rest period allows the wash water and suds to drain from the pans After the rest cycle the rinse cycle begins During the...

Страница 16: ...m off in the sink 4 Spray down the inside of the machine 5 Brush off the heating element electric models and anywhere that doesn t come clean from spraying with the hose Note On electric models brushi...

Страница 17: ...Rinse lights are working Check if pump pressure during wash cycle is within recommended range 45 60 psi Check if rinse pressure is approximately 20 psi Note This must be checked during rinse cycle for...

Страница 18: ...ng wash nozzles Replace nozzles or wash arm Wash temperature too low Thermostat set too low Adjust wash thermostat Wash element blown Replace wash heating element Rinse temperature too low Thermostat...

Страница 19: ...gas valve are in the OPEN position 5 Reset ignition control try again To reset control a Turn On Off switch to Off position b Wait one minute turn switch to On position 6 If above steps do not light...

Страница 20: ...is turned to the on position Is the wash tank filled with water water visible above scrap trays Is there incoming 3 phase power at the control panel Is there power on the primary side of the transform...

Страница 21: ...______________________________________________________________________________________ 21 Does the wash light illuminate when the start button is pushed Is the pump circuit breaker tripped in the cont...

Страница 22: ...5 Miscellaneous Parts Part Number Description 517 5001 Adjustable Leg 517 5004 Utensil Basket 103 2009 Pump Screen 135 2002 Scrap Tray 105 2011 Button Guard Assembly 135 2008 Rinse Tank Electric Heat...

Страница 23: ...Threaded 509 5220 Wash Rinse Element 9 kW 208 Volt Clamp 509 5221 Wash Rinse Element 9 kW 230 Volt Clamp 509 5224 Wash Rinse Element 9 kW 460 Volt Clamp 507 5007 2 Sanitary Clamp Gasket for Heaters 50...

Страница 24: ...510 5092 Pump Motor Shaft Sleeve Berkeley Pump 510 5094 Extension Bracket Gasket Berkeley Pump 510 5252 10 Hp Pump Impeller Franklin Pump 510 5260 Pump Seal Kit Franklin Pump 510 5265 Pump Motor Shaft...

Страница 25: ...Indicator Light 511 5270 Start Push Button 511 5269 Stop Push Button 511 5271 Auto Fill Push Button 511 5274 Clear Button Cover 511 5314 24 VAC Logic Controller 511 5256 Fan Speed Control 511 5179 24...

Страница 26: ...e E 6 STEAM VENT A PUMP PRESSURE GAUGE B WASH WATER TEMP GAUGE C RINSE MANIFOLD TEMP GAUGE D RINSE TANK TEMP GAUGE E RINSE PRESSURE GAUGE F DOOR HANDLE G RINSE CYCLE LIGHT H WASH CYCLE LIGHT I STOP BU...

Страница 27: ...hone 712 472 3734 Rock Rapids IA 51246 LVO Manufacturing Inc 808 N 2nd Ave E Note Height with door open 105 1 4 Door opening width 39 1 2 Door opening height 29 1 4 Front View 83 3 4 6 Steam Vent Top...

Страница 28: ...9 3 4 22 5 3 4 58 1 4 11 47 1 4 Note Height with door open 105 1 4 Door opening width 39 1 2 Door opening height 29 1 4 Ga Name Informative PT25 Gas 136 1100 1 No Mat Scale 1 24 4 30 2012 C Woiwood F...

Страница 29: ...lled on old style doors with three holes LVO Manufacturing Inc 808 N 2nd Ave E Rock Rapids IA 561246 Phone 712 472 3734 Mat Ga Finish Rev Scale Name No C Wiowood 10 27 2010 1 10 Pan Washers Door Weigh...

Страница 30: ...If necessary for extremely soiled pans place a pan in every other slot Informative Bun Pan Rack Pan Washers Phone 712 472 3734 Mat Ga Finish Rev Scale Name No C Wiowood 3 24 2011 1 4 LVO Manufacturin...

Страница 31: ...4 Mat Ga Finish Rev Scale Name No C Woiwood 4 21 2010 1 4 LVO Manufacturing Inc 808 N 2nd Ave E Rock Rapids IA 561246 112 2101P Insert pans as shown so bottom wash arms spray inside of pans If necessa...

Страница 32: ...E THIS HOLDDOWN RACK IS NOT TO BE USED AS A SHELF TO SUPPORT HEAVY ITEMS LVO Manufacturing Inc 808 N 2nd Ave E Rock Rapids IA 561246 Phone 712 472 3734 Mat Ga Finish Rev Scale Name No Marlin E 03 12 9...

Страница 33: ...9 I10 I11 I12 Q8 DISTRIBUTION LINE N BREAKER RINSE HEAT BREAKER WASH HEAT RINSE HEATER 9KW WASH HEATER 9KW LOW WATER CUTOFF 1 4 WASH SELECTOR LT MED HVY RINSE CONTACTOR HIGH LIMIT HIGH LIMIT WASH CONT...

Страница 34: ...R 9KW LOW WATER CUTOFF 1 4 WASH SELECTOR LT MED HVY RINSE CONTACTOR HIGH LIMIT 115V FAN MOTOR 208 230 460 0 24V C FUSE FAN RELAY FAN CONTROL SPEED H W WASH TEMP CONTROL IGNITION MODULE HIGH LIMIT 25V...