LVO Manufacturing, Inc.
LVO Manufacturing, Inc.
LVO Manufacturing, Inc.
LVO Manufacturing, Inc.
808 N. 2
nd
Avenue E., P.O. Box 188
Rock Rapids, IA 51246
www.lvomfg.com
(712) 472-3734
1-800-346-5749 Fax (712) 472-2203
__________________________________________________________________________________________________________________________________________________________________
20
Trouble Shooting Flowchart
Pan Washer Doesn’t Run
Does the power light illuminate when the
power switch is turned to the “on” position?
Is the wash tank filled with water
(water visible above scrap trays)?
Is there incoming 3-phase power at
the control panel?
Is there power on the primary side
of the transformer?
Is there power on the output side of
the secondary transformer fuse?
Verify the low water cut-off is working
by checking for power at terminal #4 on
the lower terminal block strip.
No
Yes
Yes
Yes
Yes
Fill the wash
tank.
No
Correct incoming power
supply problems
Check primary fuses on
control panel
Secondary transformer fuse is
blown or the transformer is
defective.
Defective or damaged
low water cut-off
Call LVO Mfg. for technical support
No
No
No
No
See Next Page
Yes