XAP-1040 Suggested Mounting Location
4.6.2 Mounting the Access Point on a Wall or Pole
The XAP-1040 can be mounted directly to a wall or pole using the included mount-
ing bracket. Once the mounting location has been selected, installation is as simple
as plugging the Ethernet cable into the RJ-45 connector and then mounting the
access point directly to the wall or pole as shown in the diagram below:
The XAP-1040 mount assembles as show above. The u-bolts may be removed and
the plate may be mounted directly to a wall using your hardware.
CAUTION:
Do not drill holes in the enclosure or the weather proofi ng
will be compromised and your warranty voided.
4.6.3 Assembling the Weather Resistant RJ-45 Connector Gland
To ensure proper protection from the elements, the weather resistant RJ-45 con-
nector gland must be installed correctly. To do so requires the installer to termi-
nate the Ethernet Cable that will be plugged into the XAP-1040. The diagram below
indicates the correct assembly for the RJ-45 Connector Gland.