Electromagnetic Compatibility (EMC) User Information

WARNING:  

Medical Electrical Equipment, such as the CLX Light Source, needs special precautions regarding 

Electromagnetic Compatibility  (EMC) and needs to be installed and put into service according to the EMC 
information provided in the following tables.

WARNING

:  Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment.

WARNING

:  The CLX Light Source should not be used adjacent to or stacked with other equipment.  If this becomes 

necessary the CLX should be observed to verify normal operation in the configuration in which it will be used.

NOTE

:  The EMC tables and other guidelines below provide information to the customer or user that is essential in 

determining the suitability of the CLX Light Source for the Electromagnetic Environment of use, and in managing the 
Electromagnetic Environment of use to permit the CLX Light Source to perform its intended use without disturbing 
other Equipment and Systems or non-medical electrical equipment.

 

Guidance and Manufacturer’s Declaration – Emissions All Equipment and Systems 

 

The 

CLX Light Source

 is intended for use in the electromagnetic environment specified below.  The customer 

or user of the 

CLX Light Source

 

should assure that it is used in such an environment. 

Emissions Test 

Compliance 

Electromagnetic Enforcement – guidance 

RF Emissions  
CISPR 11 

Group 1 

The 

CLX Light Source

 

uses RF energy only for its internal function.  

Therefore, its RF emissions are very low and are not likely to cause any 
interference in nearby electronic equipment. 

RF Emissions  
CISPR 11 

Class A 

 

The 

CLX Light Source

 

is suitable for use in all establishments 

including domestic, and those directly connected to the public low-
voltage power supply network that supplies buildings used for domestic 
purposes.  

Harmonics  
IEC 61000-3-2 

Complies or 

Not applicable 

Complies 

Flicker 
IEC 61000-3-3 

Complies or 

Not applicable 

Complies 

 

 
 

- 11 -

Содержание 00-CLX

Страница 1: ...User Manual for CLX Xenon Light Source ENGLISH...

Страница 2: ...eshooting 9 Maintenance and Cleaning 10 Specifications 10 Electromagnetic Compatibility EMC User Information 11 14 Product Warranty 15 Repair and Return 15 TABLE OF SYMBOLS Found on Light Source Atten...

Страница 3: ...and the light cable can cause eye damage if viewed directly for more than momentary periods of time Do not look directly into the light source or the cable Do not point the light cable at another pers...

Страница 4: ...The CLX light source comes with a hospital grade power cord Please verify that both the light source and the power cord have been received undamaged All fiber optic light guides should be properly cle...

Страница 5: ...t occur when the standby switch is used to control the lamp Note that if the light source is left in standby with power applied with the main power on off switch in the on position and the on standby...

Страница 6: ...nsure against failure Figure 7 Figure 6 Retaining clips locked Replace lamp when illumination is no longer satisfactory or sufficient for use To remove the lamp 1 Make sure the main power on off switc...

Страница 7: ...main power on off switch to the on position then press on standby switch to turn the unit on 5 Adjust attenuator ring to verify that the unit emits light Figure 9 Figure 8 Forward Lamp module Lamp dis...

Страница 8: ...dle screw positioned at the top of the handle slide the handle onto the upper column so there is about 5 inches 13 cm of space between the handle and the top of the column Tighten handle screw to hold...

Страница 9: ...e 850358 User Manual for the CLX Adapter Options 401193 Storz adapter Lamp 00 1187 CLX Lamp replacement module Power Cords 601949 AUSTL6M Australian Power Cord 6m 601949 EUR6M European Power Cord 6m 6...

Страница 10: ...air the unit if the lamp fails in use Turn off the unit and allow it to cool for at least 15 minutes then try to restart the unit If the lamp still fails to illuminate it may need to be replaced If yo...

Страница 11: ...nominal AC Power Leakage Leakage current to chassis with ground wire intact less than 100 microamps Leakage current to chassis with ground wire interrupted less than 500 microamps Classification Type...

Страница 12: ...ironment of use to permit the CLX Light Source to perform its intended use without disturbing other Equipment and Systems or non medical electrical equipment Guidance and Manufacturer s Declaration Em...

Страница 13: ...commercial or hospital environment Surge IEC 61000 4 5 1kV Differential 2kV Common 1kV Differential 2kV Common Mains power quality should be that of a typical commercial or hospital environment Volta...

Страница 14: ...vironment specified below The customer or user of the CLX Light Source should ensure that it is used in such an environment Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environm...

Страница 15: ...or user of the CLX Light Source can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communications Equipment and the CLX Light Source as reco...

Страница 16: ...uxtec subjected to unusual physical or electrical stress altered with non Luxtec parts or damaged during shipment back to Luxtec This warranty is non transferable unless authorized in writing by Luxte...

Страница 17: ...the Essential Requirements specified in Annex 1 of the Medical Device Directive MDD 99 Hartwell Street West Boylston MA 01583 USA Telephone 800 325 8966 USA only or 1 508 835 9700 Facsimile 1 508 835...

Отзывы: