background image

 

38 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание BeST-SLED ISB2

Страница 1: ...Document LUX BeST SLED_V2_ISB UM 2020 07_28 2020 Luxmux User Manual Multi Channel Superluminescent Diode Light Source Multi SLED Tradename BeST SLED Integrated Spectral Bench ISB2...

Страница 2: ...products and technology Quality Policy At Luxmux we use only the highest quality components manufactured consistently to our stringent specifications After assembly we test each system in house befor...

Страница 3: ...t SLED ISB2 Register Map 25 5 Fiber Coupling 26 6 Technical Data 27 7 Dimensions 29 7 1 Dimensions BeST SLED Standard 29 7 2 Dimensions BeST SLED Low DOP 30 7 3 Dimensions BeST SLED Standard with Powe...

Страница 4: ...nescent diodes available SLEDs in a single unit Each SLED comes with a built in independent monitor photodiode and one common thermoelectric cooler TEC for all SLEDs Fiber coupled output power from 12...

Страница 5: ...zards Do not obstruct the air ventilation slots If any parts of the driver or electronics are broken or exposed contact Luxmux technical support and do not attempt to operate the unit The ISB2 is a Cl...

Страница 6: ...ntil you have inspected the contents and the unit mechanically and electrically Verify that you have received the following items within the package 1 BeST SLED Integrated Spectral Bench 1 Power suppl...

Страница 7: ...hen the unit is plugged in for power and the power button is in the I ON position the power LED of the front panel will light up The ISB2 can be powered up with the power supply provided by Luxmux or...

Страница 8: ...e shortest wavelength and SLED 1 having the longest wavelength Please refer to the Final Inspection Test Report included with the BeST SLED Integrated Spectral Bench for SLED numbering as well as corr...

Страница 9: ...s are enabled and users can turn them on When SLEDs are turned on and light is being emitted the green ON LED will light up If the ISB2 is controlled through the Luxmux software the SLED controls will...

Страница 10: ...the ISB2 Unit Air circulation is located on the back panel of the ISB2 Light Source while additional ventilation holes are located in the front panel Ensure vents are not obstructed to allow for maxi...

Страница 11: ...st be specified when placing an order If the ISB2 is controlled through the Luxmux software current and power is displayed in the UI as explained in the Software Operation section Otherwise if using L...

Страница 12: ...indows 7 32 bit 64 bit Windows 8 32 bit 64 bit Windows 10 32 bit 64 bit 3 4 Software Operation When starting up the software will automatically scan your computer s ports and find the BeST SLED ISB2 P...

Страница 13: ...Each SLED s current can be adjusted using its specific sliding bar Additionally all SLEDs can be set to their Maximum or Minimum by clicking the Set Max or Set Min buttons on the left of the sliders...

Страница 14: ...e Modulation window Once Modulation is enabled the user Can enable modulation for each of the individual SLEDs Maximum Modulation Current is displayed for each individual SLED and is dictated by the S...

Страница 15: ...C The real time TEC temperatures are shown in the Temp Read box and TEC Current is shown in the Current Read box TEC Capacity represents how hard the TEC is working to maintain the temperature of the...

Страница 16: ...n speed value 0 0 to 7 0 CFM into the fan speed Set Point field then click the Set Button Note The user defined fan speed Set Point will not be saved when the unit is powered off It is recommended to...

Страница 17: ...side the wavelength value box then clicking Save To see the current output in mA select Current in the dropdown menu Current will be shown by default To see the Power output select Power from the drop...

Страница 18: ...an then clicking Manual Connect to connect via their preferred communications settings To Disconnect from a Manual Connection click the Disconnect button USB RS 232 Serial Configuration 1 COM Port can...

Страница 19: ...ST SLED unit and is used to monitor communications Logging The Best SLED ISB2 supports continuous logging of data such as the currents temperatures fan flow etc by clicking on the Logging tab from the...

Страница 20: ...e 15 The Communications log can be paused by clicking Pause exported to a file by clicking Save to Clipboard or the window can be emptied by clicking Clear In an event of a communication error send th...

Страница 21: ...s new value Clicking this button will store the new value recorded in the New Setting field as its new default start up setting The new value will be stored in the Best SLED ISB2 and not on the user s...

Страница 22: ...s should be operated per manufacturer recommended current setting provided in the Final Test Inspection Report for the BeST SLED ISB2 Running the SLEDs at higher currents may cause damage Luxmux is no...

Страница 23: ...The About window is shown in Figure 17 The software name and version are shown underneath Luxmux s logo Based on the ISB2 model the Capabilities column shows the functionality enabled on the driver T...

Страница 24: ...e Application Data Unit ADU 4 1 Serial MODBUS RTU USB interface RS232 MODBUS over Serial Line is a master slave protocol and is employed by the USB port The ADU packet structure for each serial interf...

Страница 25: ...action Identifier Protocol Identifier Length and Unit Identifier UI The Transaction Identifier indicates a specific MODBUS request response transaction and must be unique at each given time This allow...

Страница 26: ...6 5 Fiber Coupling The Best SLED is internally optimized for maximum coupling efficiency with PM1550 XP PM1300 XP or SMA 28e based on the model See table below for recommended fiber based on model typ...

Страница 27: ...on Frequency Range fmod 0 016 Duty Cycle D 10 50 90 INTERNAL MONITOR DIODE Monitor Diode Current Reading Imon 500 uA Monitor Diode Current Reading Resolution RESImon 7 6 nA LIGHT OUTPUT CONNECTOR Type...

Страница 28: ...point TPM_SET 20 40 C Power Meter TEC Temperature Setpoint Resolution RTPM_SET 0 1 C Power Meter TEC Temperature Reading TPM_READ 40 85 C Power Meter TEC Temperature Reading Resolution RTPM_ READ 0 1...

Страница 29: ...29 7 Dimensions 7 1 Dimensions BeST SLED Standard Overall dimensions for the connector venting locations and mounting holes...

Страница 30: ...30 7 2 Dimensions BeST SLED Low DOP Overall dimensions for the connector venting locations and mounting holes...

Страница 31: ...31 7 3 Dimensions BeST SLED Standard with Power Meter Overall dimensions for the connector venting locations and mounting holes...

Страница 32: ...32 7 4 Dimensions BeST SLED Low DOP with Power Meter Overall dimensions for the connector venting locations and mounting holes...

Страница 33: ...nd the diagnostic file follow these steps 1 While your unit is connected and running click on the About button on the main screen to open the About window 2 Click Select Diagnostic File button and sav...

Страница 34: ...ned from LUXMUX that do not comply with the warranty and which are returned to LUXMUX during the applicable warranty period will be repaired or replaced at LUXMUX s option provided the reseller or end...

Страница 35: ...ber removed or altered The warranty does not cover abuse of the product including but not limited to neglect damage or mis use such as water damage back reflection broken fiber incorrect input voltage...

Страница 36: ...iode ISB Integrated Spectral Bench PCB Printed Circuit Board TEC Thermal Electric Cooler ESD Electrostatic Discharge API Application Protocol Interface PDU Protocol Data Unit ADU Application Data Unit...

Страница 37: ...37 12 Ordering Code 12 1 Standard BeST SLED models...

Страница 38: ...38...

Страница 39: ...An Integrated InGaAs Power Meter can be added to BeST SLED models upon customer request The power meter adapters can come with FC APC FC PC or SMA connectors Please indicate on the order if customer r...

Отзывы: