background image

2

Features of This Unit

4 parallel push-pull output stages

4-parallel push-pull amplification circuit structured with 
3-stage Darlington.
Rated output of 120 W+120 W (8Ω), 210 W+210 W (4Ω).

ODNF  
- Only Distortion Negative Feedback -

The amplification feedback circuit that has acquired the high-
speed primary slew rate and ultra-wide bandwidth by feeding 
back only distortion components generated during amplifica-
tion for the main amplifier to maintain the pure sound quality 
that is almost non-feedback.
With ODNF’s latest version 4.0, in the amplification circuit, 
the first stage is 4-parallelized and the second stage is con-
nected with Darlington. Due to these improvements, the low 
impedance and high S/N ratio of the transmission circuit have 
become possible.
In addition, the input stage of the error detection circuit is 
3-parallelized to improve distortion and noise.

BTL connection mode

The BTL connection mode with use of 2 units of this product 
has achieved a high-quality and high-power monaural ampli-
fier structure.

2-channel input selector

Switching between unbalanced input of RCA terminal sup-
porting large plugs and balanced input of XLR terminal manu-
factured by Neutrik that supports high-grade balanced signal 
transmission is possible.

Balanced input phase selection

Balanced input phase selection switch is equipped, which is 
useful for the case of connecting foreign-made input devices.

Selector relay

Selector relay with high sound quality used in Luxman ampli-
fiers enhances the separation and crosstalk performances.

High-inertia power supply

L and R separated high-inertia power supply circuit combin-
ing a large-capacity EI-core-type power transformer with cus-
tomizable 10,000μF × 8 block capacitors are used.

Содержание M-700U

Страница 1: ...Owner sManual STEREO POWER AMPLIFIER M 700u...

Страница 2: ...Contents Precautions 1 Features of This Unit 2 Names and Functions 4 Connections 8 Block Diagram 12 Specifications 13 Before Asking for Repair Services 14...

Страница 3: ...current may be passed through the output circuit and cause a malfunction The sound is not generated shortly after the power supply is turned on This amplifier is equipped with a time muting circuit in...

Страница 4: ...tion the input stage of the error detection circuit is 3 parallelized to improve distortion and noise BTL connection mode The BTL connection mode with use of 2 units of this product has achieved a hig...

Страница 5: ...o the spiral wrap shielding on each core and the non plating processing on the core wire High grade analog meter Large sized analog meter with shower light is equipped Light OFF meter OFF is selectabl...

Страница 6: ...standby state to operation state When the main power switch on the rear panel is turned on to set this unit to the standby state turn this switch on Then this unit is set to the operation state When...

Страница 7: ...lights ON power meter display ON left The setting of the display switch is memorized in both STE REO and BTL MONO respectively 7 BTL indicator BTL Lights when the BTL selection switch on the rear pane...

Страница 8: ...the front panel lights yellow to show that this unit turns to the standby state When this switch is turned off the standby indicator on the front panel turns off to show that the main power is turned...

Страница 9: ...d to this unit When BTL MONO is selected this unit acts as a monaural power amplifier Therefore either right or left speaker sys tem can be connected exclusively If stereo playback is desired another...

Страница 10: ...ed cable Please be very careful to prevent wrong connection between right and left channels If the right and left channels are con nected reversely the localization of sound images is deterio rated th...

Страница 11: ...00u for the right channel Securely connect the terminal of the speaker system to the red SPEAKERS L terminal BTL of this unit and the terminal of the speaker system to the red SPEAKERS R terminal BTL...

Страница 12: ...10 CONTROL AMP SPEAKER SYSTEM L R L R REMOTE CD SACD PLAYER CD SACD PLAYER L R L L R R Connections Normal stereo playback...

Страница 13: ...STEREO POWER AMPLIFIER M 700u 11 CONTROL AMP CD SACD PLAYER CD SACD PLAYER L R L R REMOTE SPEAKER SYSTEM L R R R L L Set to BTL MONO Set to BTL MONO BTL stereo playback...

Страница 14: ...OWER SWITCH AC RELAY 1 AC RELAY 2 TRANS AMP TEMP REG ODNF AMP RECT OP RECT ODNF RECT RELAY RECT PWR RECT PWR RECT COM TRANS CONTROL OUT SP L SPEAKER OUT L SPEAKER OUT R OUT SP R DC OC PRT TEMP PRT DC...

Страница 15: ...20kHz 0 3 0dB 1Hz 130kHz S N ratio 115 dB IHF A weighted input short Damping factor 350 Attached equipment Main power switch Operation switch Input switch BTL selection switch Phase inverter switch Po...

Страница 16: ...e minimum position Adjust the output level No sound is generated on one side The connecting cable is not connected on one side only Make cable connections securely Sound is generated but the sound vol...

Страница 17: ...STEREO POWER AMPLIFIER M 700u 15 MEMO...

Страница 18: ...16 MEMO...

Страница 19: ......

Страница 20: ...LUXMAN CORPORATION JAPAN AG00987E35A Printed in China...