Luxibel LX305 Скачать руководство пользователя страница 7

 

LX305 

V. 02 – 22/05/2014 

©Velleman nv 

Channel mode 

First unit 

Second unit 

Third unit 

Highest 

start address 

Start address 

2 (1 + 1) 

3 (2 + 1) 

512 

 

Channel 

1 - 1 

2 - 2 

3 - 3 

 

Start address 

6 (1 + 5) 

11 (6 + 5) 

508 

 

Channel 

1 - 5 

6 - 10 

11 - 15 

 

Start address 

9 (1 + 8) 

17 (9 + 8) 

505 

 

Channel 

1 - 8 

9 - 16 

17 - 24 

 

10 

Start address 

11 (1 + 10) 

21 (11 + 10) 

503 

 

Channel 

1 - 10 

11 - 20 

21 - 30 

 

 
 

7.5

 

DMX Channel Values 

1 channel mode 
channel 

function 

value 

percent/setting 

Flash 

000-005 
006-249 
250-255 

Blackout 
Flash rate, slow to fast 
Continuous blinder effect 

 

5 channel mode 
channel 

function 

value 

percent/setting 

Flash intensity 

000-005 
006-255 

Black out 
Minimum to maximum 

Flash duration 

000-255 

Flash duration 
15 – 990ms 

Flash rate 

000-005 
006-255 

No flash 
1Hz~30Hz 

Special effects 

000-005 
006-042 
043-085 
086-128 
129-171 
172-214 
215-255 

No effect 
Ramp up 
Ramp down 
Ramp up-down 
Random 
Lightning 
Spikes 

 
 

Pixel  control 

macros 

000-005 
006-042 
043-085 
086-128 
129-171 
172-214 
215-255 

No effect 
Macro 1 (slow to fast) 
Macro 2 (slow to fast) 
Macro 3 (slow to fast) 
Macro 4 (slow to fast) 
Macro 5 (slow to fast) 
Macro 6 (slow to fast) 
Channels 1, 2, 3 and 4 are available in 5 channel 

mode 

 

8 channel mode 
 
channel 

function 

value 

percent/setting 

Segment 1 

000-005 
006-249 

Blackout 
Flash rate (slow to fast) 

Содержание LX305

Страница 1: ...LX305 Nuxiled 1000 DMX controlled LED strobe USER MANUAL...

Страница 2: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Страница 3: ...ing defects or problems Mechanical wear and LEDs are not covered by warranty A qualified technician shall install and service this device Do not switch the device on immediately after it has been expo...

Страница 4: ...e weight of the device Make sure that the maximum height of drop is limited so that no injuries can occur If the safety cables are long wrap them around the truss multiple times to reduce the height o...

Страница 5: ...nts corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor between pins 2 and 3 which is then plugged into the XLR output socket of t...

Страница 6: ...f the previous slave device Master 1 Set up the unit as described in the section Stand Alone Mode above 2 Press MENU until M S Mode is displayed and press ENTER 3 Use UP and DOWN to select Master and...

Страница 7: ...e channel function value percent setting 1 Flash intensity 000 005 006 255 Black out Minimum to maximum 2 Flash duration 000 255 Flash duration 15 990ms 3 Flash rate 000 005 006 255 No flash 1Hz 30Hz...

Страница 8: ...us blinder effect 5 Segment 5 000 005 006 249 250 255 Blackout Flash rate slow to fast Continuous blinder effect 6 Segment 6 000 005 006 249 250 255 Blackout Flash rate slow to fast Continuous blinder...

Страница 9: ...60 161 190 191 220 221 255 No function Auto Program 0 Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program 7 10 Auto speed 000 255 Auto speed slow to...

Страница 10: ...ower supply 100 240 V 50 60 Hz PowerCon in and out power consumption 190 W LED source 324 x 0 5 W SMD 6500 K colour temperature 6500 K beam angle 120 DMX in and output 3 and 5 pin XLR dimensions 230 x...

Страница 11: ...article e g by oxidation shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits o consumable goods parts or accessories that are sub...