background image

1

.  Press the anti-tamper switch, the LEDs will flash together to indicate that the unit is operational.

3.  Hinge the front cover locating tabs over the top edge of the back plate and carefully push the base 

of the siren cover into place. Secure the siren cover in place by refitting the fixing screw in the 

bottom edge of the cover. Do not over tighten the screw as this could damage the thread.

Important: Ensure that the rear tamper switch is closed when you fit the siren cover to the back 

plate (i.e. listen for the switch to click). If the switch does not close this will prevent the Solar Siren 

from operating correctly.

4.  The fitting of the Solar Siren is now complete.

Siren Service Mode

The  Solar  Siren  includes  a  Service  Mode  facility  which  prevents  the  Siren’s  tamper  switch  from 

triggering an alarm whilst it is removed from the wall for maintenance or to change the batteries. After 

changing the batteries and refitting in position, the Solar Siren must be put back into Operating Mode, 

otherwise it will not sound in the event of an alarm.

Service Mode: 

Press and hold the 

 button on the Remote Control.

The Siren will produce two short beeps/LED flashes and then after approximately 6 seconds a single 

long beep/LED flash followed immediately by two short beeps/LED flashes to indicate that it has 

switched into Service Mode.

Operating Mode:

 Press and hold the 

 button on the Remote Control.

After approximately 6 seconds the Siren will produce a single long beep/LED flash to indicate that it 

has switched into Operating Mode.

External Connections

The Control Panel incorporates a terminal block for connection of an external Hard-wired Siren or 

Telephone Dialler Unit. The connection terminal block is located inside the Control Panel behind the 

front cover.

To access the terminal block, press:

,

 

User Access Code

 

This puts the system into Test Mode and prevents an alarm occurring. Undo the two fixing screws 

on the top edge of the Control Panel and open the front cover. Before  making  any  connections,  

ensure  that  the memory jumper link P1 is in the ‘OFF’ position and then remove the DC power jack 

and disconnect the back-up batteries.

Содержание LHC100SK

Страница 1: ...one Wire Free Intruder Alarm System LHC100SK LHK101SK Instruction Guide For system installations incorporating the 6 Zone Control Panel refer to this Manual and disregard any other instructions suppli...

Страница 2: ...ial Power Up of the Solar Siren 20 Siren Service Mode 21 External Connections 21 Testing the System 22 Initial Testing 22 Testing an Installed System 22 Detector Test 23 Hard Wired Solar Siren Test 23...

Страница 3: ...Contact Detector Remote Control Batteries included x 3 6V 1 2Ahr Sealed lead acid battery for Control Panel and External Solar Siren x 2 9V PP3 Alkaline battery for PIR Movement Detectors x 5 3V CR203...

Страница 4: ...ire mode provides 24 hour monitoring of any Fire Smoke detectors incorporated into the system Entry Exit Delay Each zone can be programmed to be Armed in either Instant or Delay mode Usually the zone...

Страница 5: ...sequence will be called The dialler will continue calling each number in turn until either all numbers in the sequence have been dialled the set number of times or the dialling sequence is cancelled...

Страница 6: ...Control Panel is then programmed to operate only with devices set to this House Code All Detectors and Remote Control Unit s must be set with the same House Code in order for the system to operate co...

Страница 7: ...Contact Detector PIR Movement Detector PIR Movement Detector Remote Control 1 2 3 4 ZONE 5 6 FIR E TAM PER 1 2 3 4 5 6 7 8 9 0 ESC LED Control Panel Magnetic Contact Detector SHED Back Door KITCHEN HA...

Страница 8: ...f their reach 3 It is recommended that the Control Panel should be positioned such that the Exit Entry tone emitted by the Control Panel can be heard from outside the property 4 The Control Panel shou...

Страница 9: ...e Terminal Blue Lead Terminal Black Lead Reset Jumper Link P1 Power Supply Jack Socket Inside view of Control Panel 4 Fit two 18mm No 4 screws into the top holes until almost fully home and hang the C...

Страница 10: ...en it will need extending using a coupler and extension lead not supplied Note If the Panel Tamper alarm sounds during the installation reset the alarm by pressing 1 2 3 4 on the Control Panel Keypad...

Страница 11: ...te Control Unit The Remote Control Unit is used to Arm Part Arm and Disarm the system The Remote Control Unit also incorporates a Panic switch Activating the Panic switch on the side of the Remote Con...

Страница 12: ...ected an alarm signal will be generated if the system and alarm zone is armed Note PIR Detectors will also detect animals so ensure that pets are not permitted access to areas fitted with Passive Infr...

Страница 13: ...selected for the PIR Detector is within effective range of the Control Panel It is recommended that prior to installation the Detector is set and tested with the Control Panel in Walk Test mode to en...

Страница 14: ...ivity feature designed to compensate for situations where the Detector may be affected by environmental changes e g insects air temperature etc This feature is called Detection Sensitivity and may be...

Страница 15: ...The Panel will beep and the Zone 1 LED will illuminate 2 Walk into and move slowly around the protected area each time the PIR Detector senses movement the LED behind the lens will flash In addition t...

Страница 16: ...ew fitted within the battery compartment Carefully drill out the centre of the fixing screw hole in the battery compartment using a 3mm drill Do not over tighten the fixing screws as this may distort...

Страница 17: ...ully refit the battery holder onto the Detector ensuring that the spring connectors slide onto either side of the circuit board 10 Fit the battery cover into position on the Magnetic Contact Detector...

Страница 18: ...mmediately generate a full alarm should any unauthorized attempt be made to interfere with and remove the Solar Siren cover The Solar Siren is powered by a high capacity battery A Solar Panel mounted...

Страница 19: ...ing Adaptor Input 6 Volt 1 2Ahr Rechargeable Battery Beep Disable Link P2 P3 Siren Disable Link P1 Jamming Detection Link 9 Volt PP3 Initial Power Up Battery Main Configuration Switch in SIREN Positio...

Страница 20: ...uit board Siren Disable If for any reason you need to disable the Siren remove jumper link P3 on the circuit board This will prevent the Siren from sounding during an alarm condition However the Siren...

Страница 21: ...back into Operating Mode otherwise it will not sound in the event of an alarm Service Mode Press and hold the button on the Remote Control The Siren will produce two short beeps LED flashes and then a...

Страница 22: ...er and tighten the fixing screws on the top edge of the Control Panel Press ESC to leave Test mode and return to Standby Testing the System Initial Testing As the system is initially installed it is r...

Страница 23: ...y also be tested in the same way in which case the Tamper LED on the Control Panel will be illuminated Press ESC to exit Detector test Hard Wired Solar Siren Test Press 1 2 3 4 The internal relay driv...

Страница 24: ...t Warning Tone On Zone Lockout On Jamming Detection On Phone Numbers Not programmed Message Play Time 70s Alarm Message Not programmed Call Routing All numbers disabled Call Attempts 3 Dial Method Ton...

Страница 25: ...o programming mode without saving System House Code Press 1 2 3 4 The Zone LED s 1 6 Fire and Tamper LEDs will illuminate to display the current House Code setting with an illuminated LED indicating a...

Страница 26: ...FF LED ON Delay Zone LED OFF Instant Zone To change the settings of a zone press the button corresponding to the zone number The zones will switch to the opposite mode each time the button is pressed...

Страница 27: ...the External Siren will continue to sound until either the system is Disarmed or the Control Panel Alarm Duration Time expires or if activated until the 3 minute alarm time limit of the external Sire...

Страница 28: ...ing mode Press ESC to return to programming mode without saving Entry Exit Warning Tone Default setting ON Press 6 8 The zone 1 LED will illuminate to indicate the current status of the Entry Exit war...

Страница 29: ...uminate as the setting is changed Press 2 3 4 to save the new setting and return to programming mode Press ESC to return to programming mode without saving Zone Operating Modes Each alarm zone may be...

Страница 30: ...zone 4 Press 1 2 3 4 6 5 to set zone 5 Press 1 2 3 4 6 to set zone 6 The zone LED corresponding to the current operating mode will illuminate Zone 1 LED Panic Switch Zone 2 LED Intruder Zone 3 LED 24...

Страница 31: ...ds Enter the key corresponding to the required message play time the corresponding zone LED will illuminate as the setting is changed Press 2 3 4 to save the new setting and return to programming mode...

Страница 32: ...e dialing sequence and are dialed when the voice dialler is activated Default setting all numbers inactive Press 1 2 3 4 1 2 3 4 Zone LEDs 1 4 will be illuminated to indicate the active status of tele...

Страница 33: ...de without saving Operating Instructions Operating Instructions When leaving the premises the system should be Armed However before doing so check that all windows are closed and locked all protected...

Страница 34: ...Panel alarms will stop and the system will automatically re Arm itself subject to the conditions of the Zone Lockout feature Note The Solar Siren will shut down either after the programmed alarm dura...

Страница 35: ...ystem is Armed or Disarmed in the event of threat or danger by activating a Panic Button on either the Remote Control or the Control Panel Remote Control Slide the Panic Button upwards Control Panel P...

Страница 36: ...l is operated under low battery conditions the transmit LED will continue to flash after the button has been released Under normal battery conditions the LED will extinguish when the button is release...

Страница 37: ...ies Before removing the battery cover on any device or opening the Control Panel to replace the battery ensure that the system is put into Test mode to avoid initiating a Full Alarm condition The spec...

Страница 38: ...g Mode Instant Delay Arm Part Arm 1 2 3 4 5 6 You may make a note of your User Access Code and System House Code below e d o C e s u o H m e t s y S e d o C s s e c c A r e s U E C E N O e g ON 1 2 3...

Страница 39: ...nit not responding to Detectors 1 Ensure that the House Code is correctly set 2 Ensure Detector is within effective radio range of the Control Panel and equipment is not mounted close to metal objects...

Страница 40: ...dditional Magnetic Contact Detector is connected a Ensure jumper link removed b Check that additional contact is correctly wired c Ensure that Magnet is correctly positioned in relation to Detector an...

Страница 41: ...product then 1 Contact your supplier and obtain a Return Authorisation Number 2 Adequately package your product to prevent damage in transit and include the following a A copy of your original invoice...

Страница 42: ...42 Notes...

Страница 43: ...te alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detection Audible confirmation Passive Infra Red Movement Detector 26 15 mm mm...

Отзывы: