5443703-LTG-B-0418
6
Johnson Controls Unitary Products
— = Not applicable.
SYSTEM CAPACITY - Single Piece and Modular Air Handlers
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
1. CM coils available with a factory installed horizontal drain pan. See price pages for specific model number.
Stage
RATED
CFM
COOLING
MODEL
WIDTH
NET MBH
SEER
EER
TOTAL
SENS.
AL21B2421S
AVV25BE121
17.5
–
High
850
23.40
17.70
21.00
14.50
Med
550
14.10
11.20
–
18.50
Low
425
10.00
7.90
–
34.30
AL21B2421S
MVC12BN21
17.5
CM25BE1A1
High
850
23.40
18.30
20.50
14.50
Med
425
14.00
10.50
–
18.85
Low
375
10.00
8.30
–
36.85
AL21B3621S
AVV37BE221
17.5
–
High
1250
34.80
26.60
18.50
13.00
Med
700
18.80
15.30
–
17.90
Low
450
11.20
9.70
–
33.20
AL21B3621S
AVV37CE221
21.0
–
High
1175
35.00
26.00
20.00
13.50
Med
725
19.00
14.60
–
19.20
Low
450
11.20
8.90
–
35.35
AL21B3621S
MVC12BN21
17.5
CM37BE2A1
High
1175
34.80
25.80
18.50
12.75
Med
700
18.90
15.40
–
17.90
Low
450
11.20
9.70
–
33.20
AL21B3621S
MVC16CN21
21.0
CM37CE2A1
High
1175
34.80
26.00
19.25
13.00
Med
675
18.90
15.30
–
18.30
Low
475
11.30
10.00
–
33.90
AL21B4821S
AVV49CE321
21.0
–
High
1450
45.50
32.80
20.00
13.00
Med
825
25.20
19.80
–
19.05
Low
475
14.20
11.30
–
35.70
AL21B4821S
AVV49DE321
24.5
–
High
1550
45.50
34.40
20.00
13.00
Med
800
25.20
18.50
–
19.10
Low
525
14.90
11.50
–
36.20
AL21B4821S
MVC16CN21
21.0
CM49CE3A1
High
1450
45.50
32.80
20.00
13.00
Med
825
25.20
19.80
–
19.05
Low
475
14.20
11.30
–
35.70
AL21B4821S
MVC20DN21
24.5
CM49DE3A1
High
1475
45.50
32.80
20.00
13.00
Med
850
25.40
20.00
–
19.20
Low
450
14.10
11.10
–
35.65
AL21B6021S
AVV61CE421
21.0
–
High
1725
52.50
38.00
20.25
12.50
Med
1050
30.40
24.40
–
19.40
Low
800
20.60
17.30
–
37.25
AL21B6021S
AVV61DE421
24.5
–
High
1650
52.50
38.50
20.50
13.00
Med
1025
30.40
23.40
–
19.10
Low
775
20.80
16.60
–
36.25
AL21B6021S
MVC20DN21
24.5
CM61DE4A1
High
1750
52.50
38.00
20.50
13.00
Med
1075
30.40
24.80
–
19.60
Low
800
20.80
17.50
–
38.30
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°
F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°
F outdoor ambient divided by the total electric power in watt-hours at those
conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total
electric power input in watt-hours during the same period.