INSTALLATION WITH 

C-WIRE

2. 

Installing with a C-wire

Before starting

Turn off the power at the circuit breaker to 

both your heating and cooling systems before 

performing any wiring. You will not need the 

included LUX Power Bridge.

STOP

Содержание KONO

Страница 1: ...Installation Manual Smart THERMOSTAT ...

Страница 2: ...aving energy and making your home even more comfortable LUX Products offers installation and product videos Please visit LuxProducts com videos or visit our YouTube channel LUX Products Corporation To contact LUX Technical Support please call 856 234 8803 Para ver estas instrucciones en español por favor visite LuxProducts com KONOmanualsSP Drill ...

Страница 3: ...ing with a C Wire 7 10 3 Installing without a C Wire 11 14 4 Connecting to the Network 15 19 5 Appendix 20 23 KONO Smart Drill Optional Wire Stripper Smartphone Phillips Screwdriver 1 START HERE LUX Power BridgeTM Wiring Labels What s in the box Screws Wall Anchors Trim Plate ...

Страница 4: ...ant information for HomeKitTM and WiFi setup This manual is a comprehensive guide to installation and wiring Press the knob when the thermostat is idle to view the menu Rotate the knob to select an option and press again to confirm System Mode Installation Settings Fan Mode Network Connection Run Schedule System Preparing For more information about installation settings please visit LuxProducts co...

Страница 5: ...the temperature on your thermostat Hint Your system should not make any noise and you should not feel any air exiting your vents Step 1 4 Remove the front of your old thermostat from its base If you see thick black wires wire nuts or any labels that say 120 240VAC or High Voltage your system is not compatible with KONO Smart Please call LUX Technical Support at 856 234 8803 before proceeding with ...

Страница 6: ...re is connected to each terminal in your old thermostat Take a picture of your current wiring layout it may be helpful to reference this picture later Step 1 6 Confirm if you have a C Wire If you do please turn to the next page If you do not please skip ahead to page 11 ...

Страница 7: ...LATION WITH C WIRE 2 Installing with a C wire Before starting Turn off the power at the circuit breaker to both your heating and cooling systems before performing any wiring You will not need the included LUX Power Bridge STOP ...

Страница 8: ...nfiguration other than what is listed above please call LUX Technical Support for help with your installation Step 2 2 Remove each wire from its terminal make sure that they don t fall down back into the wall Step 2 3 Remove the mounting screws from the base of the old thermostat Remove the base from the wall Step 2 4 If you would like to use the trim plate or wall anchors you can install them now...

Страница 9: ...d Heat Pump on the thermostat base and referencing your wiring photo press the lever and insert each labeled wire into the top hole of the corresponding terminal If your old thermostat did not have a W1 wire but did have a W2 wire please insert the W2 wire into the W1 terminal Step 2 7hp If you have both an O wire and a B wire i e in a Trane system please install the B wire to the C terminal For m...

Страница 10: ...s clicked into place return power to your heating and cooling system Step 2 9 After your thermostat powers up you are ready to configure KONO Smart for your heating and cooling system and connect to a wireless network Please skip ahead to the Connecting to the Network section of this manual on page 15 ...

Страница 11: ...llation without C wire you will need to access your furnace Before starting Turn off the power at the circuit breaker to both your heating and cooling systems before performing any wiring STOP INSTALLATION WITHOUT C WIRE 3 1 Install and wire your KONO 2 Install LUX Power Bridge at your furnace ...

Страница 12: ...onal 1H 1C Y G W R Conventional 2H 1C Y G W1 W2 R If you have a different configuration other than what is listed above please call LUX Technical Support for help with your installation Step 3 2 Remove each wire from its terminal make sure that they do not fall down back into the wall Step 3 3 Remove the mounting screws from the base of the old thermostat Remove the base from the wall Step 3 4 If ...

Страница 13: ...ed wire into the top hole of the corresponding terminal Connect as follows Y Wire Terminal 1 W Wire Terminal 2 R Wire Terminal 3 G Wire Terminal 4 Step 3 7 Securely fasten KONO Smart onto its base Step 3 8 Go to your furnace remove the door or panel and locate your control board or transformer In most cases there should be four wires running from the furnace to your thermostat Y G W and R If you h...

Страница 14: ... 3 10 Secure the LUX Power Bridge to your furnace If you had to remove a panel or door to access your control panel replace it now Step 3 11 Return power to your heating and cooling system If your system including your thermostat does not power up please call LUX Technical Support After KONO Smart powers up you are ready to configure it for your heating and cooling system and connect to a wireless...

Страница 15: ...r no fan Set the valve type to O or B look at the photo of your wiring to see which you have Note For advanced settings please visit LuxProducts com KONOmanual or call LUX Technical Support Step 4 2 After confirming your system settings KONO Smart will ask if you would like to connect to the network Select ON to begin connection or OFF to connect later If you wish to connect please make sure that ...

Страница 16: ...IONS IN MM GENERAL TOLERANCES LINEAR 0 2 100 0 mm 2D QR CODE format rules 1 Format DDMMYYXXXXXX 2 1th to 6th digits are the date code where YY is year MM is month and DD is day e g 9th Mar 2015 YY 15 year MM 03 month DD 09 day 3 7th to 12th digits are the serial number in numeric characters The serial number should be reset to 000001 for e different date code e g XXXXXX 000001 4 KONO3 and DDMMYYV ...

Страница 17: ...hold the knob for 5 seconds Locate your accessory s HomeKit Code under the Décor snap cover When prompted use your iPhone or iPad s camera to scan the code After the App scans the code your App and thermostat will handle the remaining steps in the connection process CONNECTING TO THE NETWORK 4 When you see the thermostat s idle screen it means you are connected You can now replace the Décor snap c...

Страница 18: ...fter connecting your thermostat to the network please return to the App and select your home WiFi network from the list and enter your password Please make sure your phone reconnects to your home WiFi network and then return to the LUX App From this point your thermostat and App will handle the remaining steps in the connection process When you see the thermostat s home screen it means you are con...

Страница 19: ... home more comfortable Personalize your KONO Smart It s more than a thermostat it s décor Match KONO to your style by simply changing the Décor snap cover Check out our wide variety of designer colors and finishes at LUXProducts com shopcovers Hibiscus Red Sea Green Deep Blue Wood Grain Midnight Black CONNECTING TO THE NETWORK 4 ...

Страница 20: ...onal Heat Pump Power Bridge HEAT STAGE 1 HEAT STAGE 2 FAN COOL C W1 W2 G Y1 RC RH C W1 O B G Y1 RC RH 4 1 2 3 Furnace Thermostat Notes The W2 terminal is used for 2 stage heating systems only If you have both an RH and RC wire please remove the red cap from the back of the thermostat ...

Страница 21: ...Diagram APPENDIX 5 Transformer Conven onal Heat Pump Power Bridge AUX EMER Heat CHANGEOVER VALVE FAN COOL C W1 W2 G Y1 RC RH C W1 O B G Y1 RC RH 4 1 2 3 Heat Pump Thermostat Notes The W1 terminal is used for Auxiliary Emergency heat or on Dual Fuel systems ...

Страница 22: ...t FAN HEAT STG 1 TRANSFORMER COMMON HEAT STG2 LUX Power Bridge C W1 W2 G Y1 RC RH C W1 O B G Y1 RC RH 4 1 2 3 Y G W R C 1 2 3 4 1 Y 2 W 3 R 4 G Notes If you have a heat pump or dual transformer system please call LUX Tech support If you have any wires on your furnace not shown here please leave them as is ...

Страница 23: ...brouillage est susceptible d en compromettre le fonctionnement APPENDIX 5 FCC Part 15C Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These lim...

Страница 24: ...LUX PRODUCTS CORPORATION Philadelphia PA 19112 USA LuxProducts com Designed in Philadelphia 54066 ...