background image

 

StarEye Maxi RGBW 

LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM  

p.4/17 

 

 

T: +32 3 293 35 50 

 www.lux-lumen.com 

 

2

 

Dimensions 

 

The dimensions of the main housing, a cylindrical lathed part, are 

Ø

63mm with 165 mm 

length. 

The maximum height with bracket: 100 mm (accessories exclusive)

 

 

 

Содержание StarEye Maxi RGBW

Страница 1: ...StarEye Maxi RGBW With RDM Order code 10704...

Страница 2: ...IRE AND BURNS 6 3 4 PROTECTION FROM INJURY 7 3 5 DISPOSING OF THIS PRODUCT 7 4 PHYSICAL INSTALLATION 8 4 1 UNPACKING 8 4 2 MOUNTING 8 4 3 LOCATION AND ORIENTATION 8 5 EXTERNAL CONNECTIONS 9 5 1 DC POW...

Страница 3: ...ergiestraat 53A 2610 WILRIJK BELGIUM p 3 17 T 32 3 293 35 50 www lux lumen com 1 Picture 1 1 General StarEye Maxi RGBW StarEye Maxi RGBW on bracket included with snoot optional 1 2 Range of lenses 9 1...

Страница 4: ...estraat 53A 2610 WILRIJK BELGIUM p 4 17 T 32 3 293 35 50 www lux lumen com 2 Dimensions The dimensions of the main housing a cylindrical lathed part are 63mm with 165 mm length The maximum height with...

Страница 5: ...read this manual and ensure yourself that you completely understand its content Observe the safety precautions in this manual Install and operate the led unit only as described in this manual and in c...

Страница 6: ...l regulations Please ensure yourself that the AC to DC power supply is able to deliver the rated current requirements of the installation If any cable seal or housing is damaged cracked or reformed di...

Страница 7: ...ssories are securely fastened Verify that the led unit is firmly fixed to its supporting underground 3 5 Disposing of this product This led lighting device is manufactured in compliance with directive...

Страница 8: ...lf that there is sufficient and unrestricted air flow around the StarEye Maxi RGBW led unit 4 1 Unpacking The following items are included in your package Led fixture with focussing bracket included P...

Страница 9: ...ower supply permanently In case of inversed polarity the warranty is void Power supply Rated voltage The rated input voltage range of the StarEye Maxi RGBW led fixture is 24 VDC Due to the use of a st...

Страница 10: ...Immunity according to EN 61547 2009 General EMC immunity requirements lighting eq EN 61000 4 1 2006 General immunity testing techniques EN 61000 4 2 2008 ESD immunity test EN 61000 4 3 2006 A1 2007 R...

Страница 11: ...It uses a simple stabilized DC power supply of 24 volt DC Power consumption 8Watt Power voltage 24 VDC Current max 700 mA full rated output Weight approx 450gr DMX controlled with RDM Individually di...

Страница 12: ...and allow all electronic devices to discharge and cool down before executing any service or maintenance 8 2 Cleaning The StarEye Maxi RGBW led unit itself Extensive dirt and particle build up degrades...

Страница 13: ...Changing Lenses Step 1 Screw the front cover counterclockwise to remove it from the led unit Step 2 Take out the lens Don t touch the led itself to avoid damage Step 3 Insert the new lens into the led...

Страница 14: ...ill be borne by the customer Limitations Lux Lumen will not warrant the following Periodic check ups maintenance and repair or replacement of parts due to normal wear and tear Consumables Any software...

Страница 15: ...product Defects caused by improper condition of the power supply network Inadequate packaging of the product when returning it under the RMA procedure Accidents or disasters or any cause beyond the co...

Страница 16: ...the RMA document we cannot accept the material The procedure to obtain a RMA Step 1 Customer contacts Lux Lumen about warranty defects if material has to be returned Step 2 Lux Lumen sends the custome...

Страница 17: ...g current DC Direct current F Temperature in degrees Fahrenheit C Temperature in degrees Celsius LED Light Emitting Diode CRI Color Rendering Index RDM Remote Device Management RGBW Red Green Blue Whi...

Отзывы: