Control
Menu settings at initial commissioning
33
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
10.3.3 Release input
10.3.4 Release code
10.4 Menu settings at initial commissioning
On first connecting the dosing pump to the mains or resetting it to the
factory default setting, it is automatically in the
Language
menu
(menu 6.3). The system prompts you to specify the menu language.
Fig. 10-4: Menu 6.3 Language
1.
Use the
or
key to choose a language.
2.
Press
OK
.
The dosing pump displays menu 6,
Setup system.
3.
Press
Menu
.
The dosing pump displays menu 1
Main menu.
4.
Press
Back
.
The dosing pump displays the start screen. In the factory default
setting, the
Manual mode
operating mode is preset and saved
with a stroke frequency of 0 % (no dosing).
Fig. 10-5: Start screen of the dosing pump after initial commissioning
10.5 Main menu
Press
Menu
.
The dosing pump displays menu 1
Main menu.
Fig. 10-6: Main menu
The main menu lists the main functions of the MAGDOS LP dosing
pump:
Operating mode
(see “Operating modes” on page 41),
Venting
(see “Venting the dosing pump” on page 40),
Scaling
(see “Scaling the delivery capacity” on page 40),
Calibration
(see “Calibrating the dosing pump” on page 41),
System setup
(see “System setup” on page 33),
Info
(see “Information about the dosing pump” on page 38),
Messages
(see “Messages of the control unit” on page 38).
10.6 System setup
In the
System setup
menu item, you configure all the dosing param-
eter's general parameters that do not depend on an operating mode.
1.
Press
Menu
.
2.
Use the
or
key to choose the
System setup
menu item and
press
OK
.
The dosing pump displays the
System setup
menu.
Fig. 10-7: System setup menu
10.6.1 Set "Time" menu item
1.
Use the
or
key to choose the
Time
menu item and press
Setup
.
2.
Use the
+
and
-
keys to set the desired hour and press
Next
.
3.
Use the
+
and
-
keys to set the desired minute.
4.
Press
Back
.
The time is set.
Batch mode (interval/timer mode)
Network mode (MAGDOS LP-Net only)
Symbol
Meaning
Active and open
Active and closed
Table 10-5: Explanation of the menu icons – Release input
Symbol
Meaning
Password protection active
Table 10-6: Explanation of the menu icons – Release code
Symbol
Meaning
Table 10-4: Explanation of the menu icons – Operating modes
Language
Deutsch
English
Back
6.3
OK
Ļ
Manual mode
Menu
Stop
-
+
Liter
h
0%
0.00
For a complete overview of the control unit's menu structure,
see page 57.
If you keep the key pressed down, the dosing pump keeps
incrementing the value by two hours or two minutes.
Scaling
Venting
Back
1
OK
Operating mode
Ļ
i
Language
Date
Menu
6
Setup
Time
Ļ
i
Содержание MAGDOS LP
Страница 2: ......
Страница 70: ...70 Solenoid Diaphragm Dosing Pump MAGDOS LP Lutz Jesco GmbH 2014 Operating Instructions BA 10231 02 V03 Notes ...
Страница 75: ......