Operation
Operating modes
41
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
11.1.3 Calibrating the dosing pump
In dependence on the dosing medium you are using and the existing
delivery pressure, you must match the theoretical delivery capacity with
that which is actually measured. You use the
Calibration
function to
do this.
Precondition for action:
The plant sections on the discharge side of the dosing pump have
been installed correctly and are ready for operation.
Perform the following working steps:
1.
Fill the metering container with the dosing medium.
2.
Hold the end of the dosing pump's suction line in the metering
container.
3.
Vent the dosing pump, (see „Venting the dosing pump“ on page 40).
4.
Press
Menu
.
5.
Use the
or
key to choose the
Calibration
menu item and
press
OK
.
The dosing pump displays menu 5
Calibration.
Fig. 11-3: Menu 5 Calibration
6.
Use the
+
and
-
keys to set the percentage value of the delivery
capacity with which you want to carry out calibration. Setting range
10 % - 100 %.
7.
Press
Start
.
The dosing pump starts delivery and displays the number of
executed strokes.
8.
Press
Finish
as soon as you have achieved a measurable value
in the metering container.
The dosing pump stops and displays the theoretical value of the
delivery rate in ml.
Fig. 11-4: Menu 5.3 Calibration
9.
Read off the actual delivery rate from the metering container and
use the
+
and
-
keys to correct the displayed delivery capacity.
Adjustment range: -50 % - +50 %.
10.
Press
OK
.
The dosing pump is calibrated.
11.2 Operating modes
The MAGDOS LP dosing pump offers the following operating modes:
Manual operation
- Manual setting of the delivery capacity,
Analog input
- Controlling the delivery capacity by means of a 0/4
- 20 mA signal,
Pulse input
- Controlling the stroke frequency and number of
strokes in dependence on the number of pulses and the pulse
spacing,
Batch mode
- Controlling the delivery capacity and the delivery
rate by means of manual starting, an external pulse at intervals or
specified times in different modes,
Network mode
(MAGDOS LP-Net only) - Controlling the stroke
frequency and number of strokes across a network.
11.2.1 Manual mode
11.2.1.1 Selecting the operating mode
1.
Press
Menu
.
2.
Use the
or
key to choose the
Operating mode
menu item
and press
OK.
3.
Use the
or
key to choose the
Manual operation
menu item
and press
OK.
The dosing pump displays the start screen of
Manual opera-
tion
mode.
Fig. 11-5: Start screen of Manual operation
11.2.1.2 Starting the dosing pump
1.
Press the
+
key to increase the stroke frequency by 1 %.
The dosing pumps starts dosing immediately. The system auto-
matically calculates the resulting delivery capacity and displays it.
2.
Use the
+
and
-
keys to set the desired stroke freqency.
Dosing pump has started.
11.2.1.3 Stopping the dosing pump
Press
Stop
.
The system displays the "Stop" signal and
Stop
changes to
Start
. Press
Start
to restart the dosing pump.
Dosing pump has stopped.
Calibration
Capacity 100 %
Menu
5
Start
-
+
Calibration
Capacity 5.67ml
Menu
5.3
OK
-
+
Factory setup +0.0%
CAUTION
Danger of automatic start up!
If the dosing pump is in manual mode with a specified stroke fre-
quency, it retains the stroke frequency even after you disconnect if
from the mains and then reconnect it. This means that dosing
medium can escape. Depending on the type and hazardousness of
the dosing medium, this can result in injury.
Stop the dosing pump before disconnecting it from the mains
supply.
Ensure that the dosing pump has been installed correctly before
connecting it to the mains supply.
Manual mode
Menu
Stop
-
+
Liter
h
0%
0.00