Technical Data
Electrical data
13
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
5.2.1 Permitted temperature of the medium
5.3 Electrical data
5.4 Other data
Information
Value
MAGDOS LP (all sizes)
Dosing head made of PVC
°C
0 – 35
Dosing head made of PP
°C
0 – 60
Dosing head made of PVDF
°C
0 – 80
Dosing head made of stainless steel (1.4571)
°C
0 – 80
Table 5-3: Permitted temperature of the medium
Information
Value
MAGDOS LP size
05
1
2
4
6
10
15
Voltage supply
110 - 240 V AC, -10% / +5%. 50/60 Hz
Power consumption
W
10
15
21
27
28
29
26
Max. current consumption during dosing stroke
A
2.0
3.0
3.7
3.8
4.1
3.6
Eco-Mode 1
Power consumption
W
8
11
17
18
20
22
19
Max. current consumption during dosing stroke
A
1.7
2.5
2.9
3.1
3.6
2.9
Eco-Mode 2
Power consumption
W
7
10
13
14
17
16
15
Max. current consumption during dosing stroke
A
1.5
2
2.2
2.7
2.4
Table 5-4: Electric data
Information
Value
MAGDOS LP size
05
1
2
4
6
10
15
Weight (with dosing head made of PVC, PP or
PVDF)
kg
~ 3.2
Weight (with dosing head made of stainless
steel (1.4571))
kg
~ 4.3
Diameter of diaphragm
mm
24
33
39
Electrical cable
m
1.8 m (with mains plug)
Protection class
IP65 (with covering caps on the connections)
Insulation class
F
Valve connection
G 5/8 external
Valve size
DN3
DN4
Table 5-5: Other data
Содержание MAGDOS LP
Страница 2: ......
Страница 70: ...70 Solenoid Diaphragm Dosing Pump MAGDOS LP Lutz Jesco GmbH 2014 Operating Instructions BA 10231 02 V03 Notes ...
Страница 75: ......