background image

Page 13

8

MDU WITH SV-IR INFRARED RECEIVER MODULE

Sivoia

system covered by

decorative valence

The SV-IR allows the MDU to be controlled directly with a 

Sivoia

Infrared Handheld Transmitter (SV-OCIT, SV-3PIT, or

SV-4GD-OCIT).  The SV-IR receiver connects to the MDU via a 20” (51 cm) cable. This provides the SV-IR receiver
ample mounting range to offset any infrared signal restriction caused by a protective/decorative covering for the shade
system. To extend the IR receiver mounting range, add up to five (5) SV-IR-EXT-10  extension cables (10 ft [3 m] each).

Note:

To control an individual shade with an IR transmitter, the SV-IR 

must

be connected to that MDU. If there is a

Group/Subgroup of MDU’s with the same Room/IR Address (see page 11),the SV-IR need only be  connected to
one of those MDU’s to control the entire Group/Subgroup.

- The SV-IR receiver must be located to allow line-of-sight reception of infrared signals.
- The SV-IR has a range of 30' when receiving infrared signals.
- The SV-IR must 

NOT

be located near lighting fixtures or in direct sunlight.

- The SV-IR must be located within 50 ft. (15 m) of the MDU it is connected to. Add up to five (5) SV-IR-EXT-10

extension cables (10 ft [3 m] each).

MDU 

SV-IR Infrared Receiver Module

Содержание VIMCO SIVOIA SV-MDU-20-KIT

Страница 1: ... Part Specs pg 15 Contents Motorized Shade Systems Infrared Handheld Transmitter Idler Support Fabric Roller Assembly Motor Drive Unit MDU Wallstation Controls Transformer SV IR Infrared Receiver Module A Typical Sivoia Motorized Shade System Wallstation Controls Transformer SV IR Infrared Receiver Module and Infrared Remote Control not included with this Kit Revised 5 14 01 Installation Operating...

Страница 2: ...ounting Brackets MDU Idler Support Ceiling Mount Brackets Idler Support 1 2 Idler and MDU Truss head Screws x8 2 Pan Head Mounting Bracket Screws x8 Home Position Reset Lever A or B 2 Phillips Screwdriver 1 8 in Straight Blade Screwdriver Power Drill Drill Bits Screwdriver Attachments Level Pliers Tape Measure Wire Cutter Wire Stripper TOOLS REQUIRED ...

Страница 3: ...er Invoice to accurately position the mounting brackets Bracket to Bracket Width FW 4 102 mm Fabric Width FW 2 3 4 70 mm 1 1 4 32 mm Bracket to Bracket Width FW 4 102 mm Fabric Width FW 2 3 4 70 mm 1 1 4 32 mm Figure 1 Standard Mounting Bracket Application Figure 2 Ceiling Mount Bracket Application ...

Страница 4: ... window exposure when the shades are in full up position B Fasten the brackets to studs in the wall using four 4 pan head mounting bracket screws Fabric Width 5 127mm 5 127mm A B Fabric Edge Fabric Edge Teeth Line up the bracket teeth with the fabric edge Once the mounting brackets have been fastened to the wall confirm the Bracket to Bracket Width as listed on the Sivoia Order Invoice Refer to Fi...

Страница 5: ...s the room Fabric Edge Wall Ceiling Bracket Top View 5 127mm Line up this bracket edge with the fabric edge Face this open ing outward towards the room when mounting Once the ceiling mount brackets have been fastened to the ceiling confirm the Bracket to Bracket Width as listed on the Sivoia Order Invoice Refer to Figure 2 on page 3 for a detailed diagram Make any necessary bracket position adjust...

Страница 6: ... ft 0 3 m of material and insert the edge of the material between the guide posts of the home position reset lever B Attach the shade to the MDU first by engaging the roller s hexagonal socket with the motor s hexagonal drive ball You may need to rotate the roller in order to push the shade over the hexagonal drive ball C Insert the idler pin into the upper slot of the idler support and drop it in...

Страница 7: ...er pin secure locked E Adjust the shade leveling screw to level the shade roller D D E E Shade Retaining Screw Locked Shade Retaining Screw Shade Leveling Screw CAUTION Not setting the shade retaining screw into the locked position prior to operating the unit can result in damage to the system ...

Страница 8: ... block according to the diagram below D Replace the terminal block and the terminal block cover Wire to a Sivoia plug in transformer junction box mount transformer or a Sivoia power panel Each MDU must be EARTH grounded One Sivoia transformer can power ONLY ONE MDU regardless of shade size Wire Type Control Description 2 conductors 22 24 AWG 3 conductors 2 shielded 1 drain 24 AWG Belden wire model...

Страница 9: ... Comm Link Comm Link Power Supply Control Next MDU Next MDU Comm Link Power Supply Wire Type Control Description 2 conductors 22 24 AWG 3 conductors 2 shielded 1 drain 24 AWG Belden wire model 1883A 3 conductors 22 AWG Lutron model SV IR EXT 10 3 conductors 2 18 22 AWG 24 VAC power supply 1 18 22 AWG earth ground 6 conductors 2 16 AWG 24 VAC power supply 1 18 AWG earth ground 3 22 AWG shielded 1 2...

Страница 10: ... point of shade travel Press the Set button The shade will move and set its Home Position automatically The display will then go blank Press the Set button to save the current position as the Upper Limit The display will read and blink for 4 seconds then go blank Press the Set Button to save the current position as the Lower Limit The display will read and blink for 4 seconds then go blank ADJUST ...

Страница 11: ...aces and individual keypads interfaces can be wired to the same MDU A maximum of 9 keypads interfaces can be wired to one MDU There are two types of Sivoia keypads and inter faces group and individual types The table to the left describes how a group type controls a sys tem depending on the setting of the MDU it is wired to An individual type only controls the MDU it is wired to regardless of the ...

Страница 12: ...ntil appears in the MDU s LED display OPEN PRESET CLOSE PRESS ONCE Shade goes to upper limit PRESS ONCE Shade goes to lower limit PRESS To lower shade PRESS To raise shade PRESS ONCE Shade goes to preset level Front View Rear View MDU Pin 1 CNTRL 1 MDU Pin 2 CNTRL 2 PRESS To lower shade PRESS ONCE Shade goes to upper limit PRESS ONCE Shade goes to lower limit PRESS To raise shade Note Pressing any...

Страница 13: ... EXT 10 extension cables 10 ft 3 m each Note To control an individual shade with an IR transmitter the SV IR must be connected to that MDU If there is a Group Subgroup of MDU s with the same Room IR Address see page 11 the SV IR need only be connected to one of those MDU s to control the entire Group Subgroup The SV IR receiver must be located to allow line of sight reception of infrared signals T...

Страница 14: ... or end brackets Check for and clear all obstructions The shade does not respond to control 1 Check that power is connected to the shade 2 Check that the wall keypad has been wired correctly 3 Check that the control terminal block is connected securely and in the proper order 4 Check batteries if using IR remote The shade does not roll straight Fabric veers or telescopes 1 If the shade veers or te...

Страница 15: ...mm 3 91 99 mm 2 84 72 mm 2 20 56 mm 3 20 81 mm 0 5 13 mm Idler Support MDU Mounting Bracket Idler Mounting Bracket Ceiling Mount Bracket MDU Dimensions B Side View A Side View B Front View Front View Side View Front View Side View Top View Side View Top View Side View Back View 3 25 82 mm 2 40 61 mm 4 102 mm 6 75 171 mm ...

Страница 16: ... and equipment external to the SIVOIA Motorized Window Shade System such as a Non Lutron lighting and automation systems b Building wiring and c Other manufacturers equipment including but not limited to i Time clocks ii Audio visual equipment and iii Photo sensors 4 The cost of repairing or replacing property or equipment other than the warranted system How to Get Service under This Warranty Shou...

Отзывы: