Lupo SUPERPANEL DUAL COLOR 30 HARD Скачать руководство пользователя страница 2

    WARNING:

When hanging the fixture from higher position, please make sure you use safety cable to 

attach the barndoors to the yoke of the panel.

Barndoors should always be used to secure the fixture and the application when used in this 

way.

Another safety cable should be used to secure the fixture to the mounting pipe or truss. 

Both safety cables must be properly dimensioned for the fixture and the application when 

the fixture is operated in hanging position please ensure that the accessories are installed 

correctly with top latch locked.

SAFETY PRECAUTIONS:

Do not operate the equipment before studying 
the instruction manual and the accompanying 
safety precautions. Make sure that Lupo 
Safety Instruction is always included with 
the equipment! Lupo products are intended 
for professional use. Do not place or use the 
equipment where it can be exposed to moisture, 
extreme electromagnetic fields or in areas with 
flammable gases or dust! Do not expose the 
equipment to hasty temperature changes in 
humid condition as could lead to condensation 
water in the unit. Equipment must only be 
serviced, modified or repaired by authorized. 
Dealers or the factory.

CAUTION - BURN HAZARD - HOT PARTS

Do not touch hot parts with bare fingers! LED 
bulbs and certain metal parts emit strong heat 
when used!
Do not point lamps too close to persons. Always 
use the fixtures with the front part closed.

NOTICE - EQUIPMENT OVERHEATING RISK

Do not obstruct ventilation by placing filters, 
diffusing materials, etc. over inlets and outlets of 
the equipment ventilation or directly over glass 
cover or LED bulbs.

FINAL DISPOSAL

Equipment contains electrical and electronic 
components that could be harmful to the 
environment.Equipment may be returned to 
Lupo distributors free of charge for recycling 

according to WEEE. Follow local legal 
requirements for separate disposal of waste, 
for instance WEEE directive for electrical and 
electronic equipment on the European market, 
when product life has ended.

MAINTENANCE AND CARE

Please do not forget that the safe operation of 
lampheads also includes their maintenance and 
care. A visual inspection should be conducted 
before every use and an inspection of electrical 
safety should be conducted at least once every 
12 months.

WARRANTY

The warranty period for Lupo products and those 
marketed by Lupo is twelve months from the 
date of delivery. Lupo guarantees that the goods 
it supplies are well manufactured and of good 
quality. The warranty guarantees the repair of 
any parts that show acknowledged defects in 
materials, construction or workmanship during 
the warranty period. The guarantee excludes 
any liability for direct or indirect damage of any 
kind and for any reason, for which Lupo will 
therefore not be required to pay compensation. 
The customers shall see to deliver the parts 
that need repair or replacement to Lupo’s works 
at their own expense and risk. The repaired or 
replacement parts shall be delivered by Lupo 
ex-works. The customers will be charged for 
materials and labor or replacement of the 
product after the expiration of the warranty 
period.

 ATTENTION:

 Please keep the original package of the 

product in a safe place for warranty reasons.

Thanks for having purchased 

Lupo

 products. All the products are made in Italy and all the efforts 

have been put to keep the quality standards high. We hope this product can help you in your job and 

make your life easier as a professional. We also hope you will enjoy its use and we would be happy to 

receive your feedback about it.

Содержание SUPERPANEL DUAL COLOR 30 HARD

Страница 1: ...Superpanel FULL COLOR 30 Hard Soft User Manual Release 4 xx...

Страница 2: ...that could be harmful to the environment Equipment may be returned to Lupo distributors free of charge for recycling according to WEEE Follow local legal requirements for separate disposal of waste f...

Страница 3: ...ed by international regulations a safety cable must be used when the fixture is suspended from ceiling To switch on the light push the on off button Superpanel models are equipped with new generation...

Страница 4: ...ht mode between CCT HSI RGBW PRESET EFFECT with the 5 knob and press the 5 push button to confirm selection 4 See LIGHT MODES DMX OPERATION 1 Press the 5 push button to enter the main MENU 2 Select DM...

Страница 5: ...GS LAST SETTINGS 1min press the 5 push button to confirm the setting Black out The device switches off Settings Last The values of the last selected setting are maintained over time until the device i...

Страница 6: ...ESET BUSY indicates that in the user preset there are parameters memorized if you select it the parameters will be replaced by the new ones EMPTY indicates that the user preset is free E SPECIAL EFFEC...

Страница 7: ...1min ALWAYS ON Menu View Type the main MENU sub menus and functions to show ONLY MANUAL ONLY DMX MANUAL DMX Filter It is the speed response of the system smooth factor FULL SPEED NORMAL SPEED HIGH SPE...

Страница 8: ...asons USB port Use USB port for firmware updates Update the Firmware 1 Copy the file on an USB Pendrive FAT32 formatted in the main root 2 Switch off the equipment and insert the USB Pendrive 3 Switch...

Страница 9: ...ng many units of Superpanel Full Color 30 to avoid overlaps MENU e submenus Select EXIT to return to the current mode Select BACK to return to the previous menu After 1 minute of inactivity in the men...

Страница 10: ...2 SPEED COPCAR 1 DIMMER 2 NUMBER OF COLORS 3 NUMBER OF FLASH DISCO 1 1 DIMMER 2 SPEED 4 4 8 8 2 3 2 MODE CHANNELS USED DMX CHANNEL POSITION 6 COLOR TEMPERATURE 6 COLOR TEMPERATURE 7 GN COMPENSATION 8...

Страница 11: ...MER byte 2 3 HUE byte 1 RGBW 1 DIMMER byte 1 2 DIMMER byte 2 3 RED byte 1 4 RED byte 2 5 GREEN byte 1 8 8 16 MODE CHANNELS USED DMX CHANNEL POSITION 4 COLOR TEMPERATURE byte 2 5 GN COMPRENSATION byte...

Страница 12: ...R byte 2 2 DIMMER byte 2 2 DIMMER byte 2 4 SPEED byte 2 4 SPEED byte 2 4 SPEED byte 2 4 SPEED byte 2 4 SPEED byte 2 6 NUMBER OF FLASH byte 2 6 FREQUENCY byte 2 6 FREQUENCY byte 2 6 BULB TYPE byte 2 6...

Страница 13: ...0001 0x0002 0x0006 0x0004 0x0008 0x0010 0x0003 0x0007 0x0005 0x0009 0x0011 PID 0x0622 DESCRIPTION Manufacturer identification number LUPO Lighting Personality DMX Personality Superpanel 60 fullcolor s...

Страница 14: ...text response with the Manufacturer name for the device LUPO is the default name DMX mode The identify flag flashes the light 0 Off 1 On 0 30 sec 1 1 min 2 always on 0 black out 1 last settings on 2 l...

Отзывы: