28
29
Betty TL2
Betty TL2
Deut
sc
h
Engli
sh
Special Functions
5
5
Alternative Capacity Indicator (lamphead)
Press and hold the button until 2
green LEDs
light up.
release the button
Before activating the alternative capacity indicator, your battery must be
fully charged.
The range of battery capacities you can choose from
will
start automatically.
3 Ah
5 Ah
7 Ah
9 Ah
4 Ah
6 Ah
Disable indicator
8 Ah
10 Ah
Default setting
You must approximate the correct range for
your battery; e.g., for an 6.6Ah you would
select 7 Ah (5 green LEDs).
Similair to our Smartcore batteries the
red
LEDs
on the lamphead will now approxi-
matley show the remaining capacity.
Attention!
When the lamp-head is discon-
nected from a battery, the indicator will
not work correctly until the battery is fully
recharged
4.
3.
2.
1.
Adjusting backlight low-battery warning:
Use this program to adjust the onset of the low-battery warning.
The threshold can be selected as shown below.
Press and hold the button, until 3
green LEDs
light up.
release the button
2.
1.
Default setting
6.0 V
5.6 V
5.2 V
6.2 V
5.8 V
5.3 V
6.4 V
6.0 V
5.4 V
6.6 V
6.2 V
5.5 V
6.8 V
6.4 V
5.6 V
Backlight:
blue
red
green
2.
Recover factory settings:
Press and hold the button, until 5
red
LEDs
turn on.
release the button
1.
Disconnect the battery, and all factory settings will be restored.
Example:
70% Remaining capacity =
3 red LEDs on, 1 red LED blinking