background image

How to Start

1. Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build.
Motor will stop when tank pressure reaches" cut-out" pressure.

2. Pull the regulator knob out and turn clockwise to increase pressure. When
the desired pressure is reached push knob in to lock in place. The compressor
is ready for use.

NOTE:

Always operate the air compressor in well-ventilated areas free of

gasoline or other combustible vapors. If the compressor is being used to
operate a sprayer DO NOT place near the spray area.

MAINTENANCE

Customer Responsibilities

Before

each

use

Daily or

after

each

use

Frequently

Yearly

Check safety valve

Drain tank

Air filter

1

Air

compressor

pump

intake and exhaust valve

1-most frequent dusty or humid conditions

WARNING

Unit cycles automatically when power is on. When performing maintenance,
you may be exposed to voltage sources, compressed air, or moving parts.
Personal injuries can occur. Before performing any maintenance or repair,
disconnect power source from the compressor and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor outfit, a
routine maintenance schedule should be prepared and followed. The following
routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the conditions under which your compressor is used. The
modifications will depend upon the hours of operation and the working
environment.

Содержание OILFREE COMPRESSOR

Страница 1: ...ulder bolt washer and one nut for each wheel using bolt holes provided in the wheel bracket The shoulder bolt will install from the outside of the wheel through the top hole in the wheel bracket Tighten securely with the washer and nut position on the inside of the wheel bracket WARNING The wheels and handle do not provide adequate clearance stability or support for pulling the unit up and down st...

Страница 2: ...the motor and to prevent overheating If an extension cord must be used be sure it is Voltage and circuit protection Refer to the Parts Manual for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical ne...

Страница 3: ...ety valve will protect against high pressure by popping out at its factory set pressure Slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to the tank pressure Tank Pressure Gauge The tank pressu...

Страница 4: ...tor stops running air will be heard escaping from this valve for a few seconds No air should be heard leaking when the motor is running or after the unit reaches cut out pressure Motor Overload Protector The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before resta...

Страница 5: ... ON AUTO position The compressor will start 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve clockwise The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Before Each Start Up 1 Place On Auto Off lever to OFF 2 Pull regulator knob o...

Страница 6: ...lter 1 Air compressor pump intake and exhaust valve 1 most frequent dusty or humid conditions WARNING Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure To ensure e...

Страница 7: ...et the On Auto Off lever to OFF 2 Pull the regulator knob out and turn clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 5 Drain water from air tank by opening drain valve counter clockwise on bottom of tank WARNING Water will condense ...

Страница 8: ...e removed by using a pair of needle nose pliers or a screwdriver Pull or pry out the old filter and carefully clean the filter area Push in the new air filter SERVICE AND ADJUSTMENTS WARNING Unit cycles automatically when power is on When doing Maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair un...

Страница 9: ...ot drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve can then be removed cleaned then reinstalled 8 Protect the electrical cord and air hose from damage such as being stepped on or run over Wind them loosely around the compressor handle Store the air compressor in a clean and dry location Troubles...

Страница 10: ...essory is being used It is normal for the gauge to show minimal pressure loss during initial use of tool Excessive tank pressure Move the Auto On Off lever to the off position If the unit doesn t shut off unplug it from the power source and contact a service technician Motor no start Make sure power cord is plugged in and the switch is on Inspect for the proper size fuse in your circuit box If the...

Отзывы: