1. Make sure the On/Auto/Off lever is in the "OFF" position.
NOTE:
If quick connect is installed, pull coupler back until it clicks to prevent
air from escaping through the quick connect.
2. Plug the power cord into the correct branch circuit receptacle. (Refer to
Voltage and Circuit Protection paragraph in the Installation section of this
manual.)
3. Open the drain valve fully (counterclockwise) to permit air to escape and
prevent air pressure build up in the air tank during the break-in period.
NOTE: Always drain tank on a washable surface or in a suitable container to
prevent damaging or staining surfaces.
4. Move the On/Auto/Off lever to " ON/AUTO" position. The compressor will
start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and
there is minimal air pressure build-up in tank.
6. After 15 minutes, close the drain valve (clockwise). The air receiver will fill to
"cut-out" pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up
1. Place On/Auto/Off lever to "OFF".
2. Pull regulator knob out. Turn counterclockwise until it stops. Push knob in to
lock in place.
3. Attach hose and accessories. NOTE: The hose or accessory will require a
quick connect plug if the air outlet is equipped with a quick connect.
WARNING
Too much air pressure causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air tools and accessories. The
regulator outlet pressure must never exceed the maximum pressure rating.