Lunos Skalar Series Скачать руководство пользователя страница 9

 

9

 

 

9

 

10

 

Two room ventilator

 

 

 

• 

One step operation, switchable to 100 m

3

/h from two 

rooms

 (ventilator type ... 30/60)

 

 

5/W 

Bridge 

5/W 

Bridge 

Room illumination 

Room 1 
60 m³/h 

Room 2 
40 m³/h 

5/W 

Bridge 

5/W 

Bridge 

Room 1 
40 or 60 
m³/h 

Room illumination 

9

 

Two room ventilator

 

 

 

• 

Continuous operation 60 m

3

/h, switchable to 100 m

3

/h 

from two rooms 

(ventilator type ... 30/60)

 

 

Room 2 
20 or 40 
m³/h 

Humidity control (ventilator types...FK) 

Room 
illuminati-
on 

Switch 

LUNOS type 5/W2 FK 
Order no.: 039 840 

Caution! Ventilators with humidity control optimally adjust the ex-
haust air volume flow by means of the room air humidity and 
temperature 

LOWERING OPERATION:

 

Volume flow 30 m³/h, independent of the room air humidity and room temperature; func-
tion active only in the "winter months" October to April 

 
 
HUMIDITY CONTROL

Volume flow 30/40/50/60 m³/h, humidity control active; function active only in the "winter 
months" October to April. 

 

The fan has an automatic summer/winter switchover. The illumi-
nated display lights up green with active humidity control and red 
with clogged filter. The fan runs from May to September in sum-
mer operation and from October to April in winter operation. Using 
an integrated supply-voltage-independent clock, the fan "knows" 
which month it is. During the cold season and the transitional pe-
riod, an excess humidification of the apartment is prevented and 
thus building damage and mold avoided. The system is controlled 
automatically and, by means of continuous adaptation of the ex-
haust air volume flow to the room air humidity and room tempera-
ture, it guarantees optimum comfort in the room to be ventilated. 
In this way, only as much ventilation as necessary, but as little 
ventilation as possible, is ensured and thus energy is saved. The 
fan never switches off completely in order to ensure a minimum 
air change. During summer months, the increased exterior air hu-
midity does not make an increased level of ventilation appropriate. 
The automatic summer/winter changeover is overridden by opera-
tion with the rocker switch Sl of the switch 5/W2 FK. 

Switch 5/W2 FK 
(front view) 

8

 

Rocker switch function description S II: 

Required ventilation ON: 

Volume flow 60 m³/h, possible coupling of the light level. 
The ventilation with 60 m³/h, by means of a priority control circuit, overrides the operating 
modes "Lowering operation" and "Humidity control", as well as the automatic summer/
winter changeover. 

Required ventilation OFF:

 

 

Fan runs in automatic summer/winter operation according to setting of the rocker switch S I. 

 

Rocker switch function description S l: 

 Remote control

: Ventilator type ... FK is remote controllable via the F+ and F- connections and with 0 to 12 V. 

 0 ≤ 2 V: Ventilator operation according to the mains connection; > 2 ≤ 4 V: ventilator OFF; > 4 ≤ 6 V: 30

 

m

3

/h; > 6 ≤  8 V:  

 40

 

m

3

/h; >8 ≤ 10 V: 50

 

m

3

/h; > 10 ≤ 12 V: 60

 

m

3

/h 

 

Temperature switch-off

: The ventilator switches off when the room temperature drops below 15°C for more than    

 1 hour and so helps to avoid freezing of the heating. When 17°C is exceeded, it switches on again. 

 

 Note

:  LUNOS standardly supplies an adhesive label set for marking switch positions when series switches from   

 an installation-switch manufacturer are used. 

Содержание Skalar Series

Страница 1: ...recautions and safety symbols with notes in the text must be observed When installation has been completed pass these directions on to the user renter owner block manager or other Symbols in these directions Danger Assembly work is only to be carried out on the ventilator when it is separated from the line voltage The ventilator is protectively insulated to protective class II the protective condu...

Страница 2: ...with a Class G2 EN 779 filter and a filter change display Ventilators of the Silvento series fulfil all requirements of DIN 18017 3 Allgemeine Bauaufsichtliche Zulassung Z 51 1 215 for low voltage CE acc to EC Directives 2006 95 EG for electromagnetic compatibility CE acc to EC Directives 2004 108 EG Waste disposal Sort the packaging for appropriate disposal Observe current requirements should you...

Страница 3: ...housings 260 mm 32 mm 69 mm 120 mm Grip 1 bis 42 mm Grip 2 ab 57 mm No grip possible bet ween 42 and 57 mm 25 5 mm 206 mm Flap valve Through the wall housing Caution Correct the flap valve position and seating if appropriate see page 5 Dimensional drawings Possible installation positioning for duct mounting ...

Страница 4: ...lation in housing 3 LS or 3 LB 2 UP Clamped ventilators can replace all build in versions of the Skalar series These installation examples are therefore only a few of many possibilities Installation in housing 3 LB 2 room ventilator Installation in housing 3 LS Installation examples ...

Страница 5: ... stick on 1a Check delivery for completeness and undamaged condition Filter Front cover plate Grid cover frame Ventilator insert for clamped ventilator Incl screws for connecting grid cover frame to ventilator insert Seal stick on when replacing a Skalar V Power supply terminal Sound insulation not with 2 room ventilators Slide nozzle with flap valve for rising building 1 Installation of clamped v...

Страница 6: ...ng diagrams Caution The mains cable must be dead 2 Top view of power supply terminal L2 L1 L N F F Plug the power supply terminal on and latch on behind the notched hook 3 Lock the power supply terminal in behind the notched hook 4b Correct the flap valve position and seating important for ceiling installation In the installed condition the flap valve in the exhaust nozzle must close because of it...

Страница 7: ...over frame and front cover plate according to the built in position of the ventilator 5 6 Flange bore holes 4 x Clamp Filter Front cover plate Grid cover frame Fitting the motion detector circuit board to the decor plate Plug the display board cable in Fasten the grid cover frame to the ventilator insert with the screws supplied and align it so that the cable lies under the motion detector circuit...

Страница 8: ...pes 100ZII Continuous operation 40 m3 h with run out time controlled 100 m3 h switch off in each of 2 rooms Ventilator types 30 100ZII 7 6 With remote control ventilator types F Note Other circuits e g via L1 or L2 are possible Remote control always has priority 0 2 V 2 4 V 4 6 V 6 8 V 8 10 V 10 12 V Ventilator operation acc to switch position Ventilator OFF 30 m h 40 m h 50 m h 60 m h Room 1 60 m...

Страница 9: ...x haust air volume flow to the room air humidity and room tempera ture it guarantees optimum comfort in the room to be ventilated In this way only as much ventilation as necessary but as little ventilation as possible is ensured and thus energy is saved The fan never switches off completely in order to ensure a minimum air change During summer months the increased exterior air hu midity does not m...

Страница 10: ...ec Run out time 15 min Inverse operation OFF Interval switching OFF White toggle switch Remove cap with a screwdriver Electrics housing Cap Interval ON every 4 hrs for 30 min Interval OFF Run out time 15 min Run out time 6 min Inverse operation 30 min after run down after the room is left Inverse operation OFF Switch on delay 120 sec Switch on delay 0 sec Accessory and replacement parts Filter pac...