1

 

Installation Manual 

Gesture Control 5/GS 

- Please forward to the user -  

Contents: 

About this manual, Safety instructions, Disposal 

 

 

 

 2 

Technical data, Shipping unit   

 

 

 

 

 3 

Assembly  

 

 

 

 

 

 

 4 

DIP switch “D/A“ 

 

 

 

 

 

 

 8 

8-way DIP switch 

 

 

 

 

 

 

 9 

Electrical connection  

 

 

 

 

 

11 

Overview of menu navigation (to cut out)   

 

 

 

16 

Commissioning 

 

 

 

 

 

 

21 

Basic operation 

 

 

 

 

 

 

22 

Standby displays 

 

 

 

 

 

 

24 

Fan control 

 

 

 

 

 

 

26 

Change of the airflow volume   

 

 

 

 

27 

Comfort functions 

 

 

 

 

 

 

28 

Resetting the filter runtime, Lock control, Learning mode 

 

 

30 

USB connection, Firmware update 

 

 

 

 

31 

Page:

 

 

Содержание Gesture Control 5/GS

Страница 1: ...ping unit 3 Assembly 4 DIP switch D A 8 8 way DIP switch 9 Electrical connection 11 Overview of menu navigation to cut out 16 Commissioning 21 Basic operation 22 Standby displays 24 Fan control 26 Cha...

Страница 2: ...and completely before installation It is essential to observe the general safety instructions and the safety symbols with notes in the text After completion of installation this manual must be passed...

Страница 3: ...her technical data depend on the connected components with 5 UNI FT Nexx t or Silvento ec and can be found in the corresponding descriptions Please check the delivery for completeness and mint conditi...

Страница 4: ...ontrol either install 5 UNI FT or lead cable out of Nexx t Select the connection cable s according to the connection diagram either J Y St Y 2 x 2 x 0 8 4 core or J Y St Y 4 x 2 x 0 8 8 core Connect t...

Страница 5: ...5 EN Attach the base plate to the switch box for switch boxes 70 mm please drill into the groove as shown For switch boxes 70mm drill into the groove Drill 3 5 mm counterbore...

Страница 6: ...6 EN Plug the control panel onto the base plate magnet attachment...

Страница 7: ...7 EN For child safety or in case of increased safety requirements against falling or theft you can fix the control panel to the base plate using a screw...

Страница 8: ...gesture control However it is possible that the connected devices can give feedback signals e g sensor data to the gesture control and this can adapt the control to the current conditions With analogu...

Страница 9: ...trol DIP switch 1 ON Ventilation unit 1 is controlled via the sensor values of the gesture control This setting is optional DIP switch 2 ON Ventilation unit 2 is controlled via the sensor values of th...

Страница 10: ...be digitally controlled to T1 and R1 Set DIP switch D A to D If only one device to be operated via analogue control is connected Connect the device to be operated via analogue control to T2 DIP switch...

Страница 11: ...s and electrical components in the ventilation unit are not allowed Electrical connection EN Notes regarding the connection diagrams For reasons of clarity the connection of 5 UNI FT Nexx t and Silven...

Страница 12: ...NI FT digital EN Note With digital connection a maximum of two 5 UNI FT or one 5 UNI FT and one Nexx t can be connected 5 UNI FT device 1 5 UNI FT device 2 12 V T1 R1 T2 R2 T R T R A connection T is a...

Страница 13: ...13 Electrical connection with 5 UNI FT analogue EN 5 UNI FT group 1 1 to 10 devices 5 UNI FT group 2 1 to 10 devices T2 R2 12 V Note Number depends on the power supply unit and device type used...

Страница 14: ...NI FT and one Nexx t can be connected If 5 UNI FT and Nexx t are used simultaneously it is more advantageous to ensure the power supply of the gesture control via the power supply unit of the 5 UNI FT...

Страница 15: ...15 Notes EN...

Страница 16: ...16 Overview of menu navigation to cut out...

Страница 17: ...17 EN...

Страница 18: ...18 Notes EN...

Страница 19: ...1 1 to 9 devices Nexx t group 2 1 to 10 devices Via Nexx t device 1 the gesture control is supplied with voltage with simultaneous operation of 5 UNI FT and Nexx t it is more advantageous to ensure th...

Страница 20: ...20 Electrical connection with Silvento ec analogue EN T2 R2 12 V Silvento ec group 2 1 to 10 devices Silvento ec group 1 1 to 10 devices separate power supply necessary e g NT18...

Страница 21: ...l and the devices connected to it 5 Plug the touch field onto the base plate If the connection is successful the LEDs on the left and right side of the gesture control will light up as follows during...

Страница 22: ...ating points The term gesture means that the hand or finger wipes from left to right or right to left horizontal gesture or from top to bottom or bottom to top vertical gesture past the control panel...

Страница 23: ...s The fifth is in the middle of the control panel If the control has not been operated for 10 seconds it will be locked to prevent accidental ly triggered gestures To unlock the control unit it must b...

Страница 24: ...touching the left or right control point in the order shown below The scrolling of the displays takes place in a rolling manner i e after the sleep mode the ambient light returns and vice versa Sleep...

Страница 25: ...he more LEDs light up the higher is the measured value Time The time is displayed via a three colour LED display The colour dots move clockwise around the control panel The seconds are displayed in wh...

Страница 26: ...or activating and deactivating comfort functions Control channel 1 is shown in blue and appears first control channel 2 is shown in green In the following the functions are explained using channel 1 a...

Страница 27: ...entilation stage are valid for one hour Rough setting Vertical gestures can be used to make a rough setting of the stage An upward wiping movement increases the executed stage a downward movement decr...

Страница 28: ...touching the respective operating point An activated comfort function is indicated by a pulsing of the middle LEDs on the respective side Night time reduction Deactivated Minimum ventilation stage Ru...

Страница 29: ...reduction and intensive ventilation The runtime shown on the upper side is roughly set by horizontal gestures and finely adjusted via the operating points on the left and right One LED stands for abou...

Страница 30: ...entilation components Lock control Learning mode To lock the control the operating point in the middle must be held down for 10s During pressing the control pulses every second If an operation or gest...

Страница 31: ...the gesture control Please use a commen micro USB cable to connect the gesture control to a PC For a communication no additional drivers are required New firmware versions and the corresponding softwa...

Страница 32: ...32 E340 11 19 LUNOS Germany LUNOS L ftungstechnik GmbH Phone 49 30 362 001 0 f r Raumluftsysteme Fax 49 30 362 001 89 Wilhelmstr 31 info lunos de 13593 Berlin Germany www lunos de Notes EN...