9-12
EQUIPMENT DETAILS
Failure display
Your refrigerator will indicate a malfunction by flashing of the failure indicator LED (4) and one of the
other display lights. The chart below shows the meaning of these.
Display:
Failure:
LED is flashing
230V mode: “230V” not available or voltage too low
LED is flashing
12V mode: “12V” not available or voltage too low
LED is flashing
GAS/Auto mode: Flame not ignited
All temperature setting
Temperature sensor defective, refrigerator work
LEDs are flashing
on mid temperature setting
LED + all temperature
230V - Heating element defective
LED + all temperature
12V - Heating element defective setting LEDs are
flashing