Problem
Cause
Solution
Skipping
fasteners/feeding
intermittently
12. Nail length is not correct with
loading space of nail housing.
13. Weld wires in nail coil is broken.
12. Adjust adjuster plate at the nail
housing tail portion according to the
recommended nail length to make
arrow on the nail housing tail pointing
to correct direction.
13. Stop using.
Runs slowly or has
power loss
1. Tool dry, lack lubrication
2. The spring in the cylinder cap is
damaged.
3. Having foreign matters between
piston assembly and cylinder.
4. Have not assembled the cylinder to
home position.
5. O-ring on the valve is dry after
disassemble.
6. Air pressure is too lower.
7. Driver is worn (sort)
8. Inner diameter of used hose is
small.
1. Use pneumatic tool oil.
2. Replace the spring in the cylinder
cap.
3. Disassemble/clean/lubricate.
4. Reassemble after disassembling.
5. Reassemble after lubricating
6. Increase the air pressure, but don't
exceed 120 PSI (8.3 bar).
7. Replace piston assembly.
8. Use bigger inner diameter of
the hose.
Fasteners are jammed
1. Fasteners are wrong size.
2. Weld wires in nail coil is broken.
1. Use recommended fasteners.
2. Stop using.
Содержание 24752-0109
Страница 1: ...Coil Nailer Spikpistol HCN65P 24752 0109...
Страница 2: ......
Страница 5: ...5 S mspecifikationer Brug kun de anbefalede s m 5 6 3 2 3 2 9 4 5 7 8 7 8 15 0 5 O 15 O 6 7 8...
Страница 13: ...13 Naelte andmed Kasuta ainult soovitatud kinnitusdetaile 5 6 3 2 3 2 9 4 5 7 8 7 8 15 0 5 O 15 O 6 7 8...
Страница 20: ...20 Kiinnittimet K yt vain suositettuja kiinnittimi 5 6 3 2 3 2 9 4 5 7 8 7 8 15 0 5 O 15 O 6 7 8...
Страница 27: ...27 Fasteners specifications Only use recommended fasteners 5 6 3 2 3 2 9 4 5 7 8 7 8 15 0 5 O 15 O 6 7 8...
Страница 74: ...74 Diagram...
Страница 80: ......
Страница 81: ......
Страница 82: ......
Страница 83: ......