background image

[2]

Luminosoled.com

LEAVE  A 

COPY  FOR

 T

HE

 U

SER

 / 

MAINTENANCE

 E

NGINEER 

FOR  FUTURE  REFERENC

E

locking bolts

Hinged hatch 

2

Cover

STEP 

2:

Pole

Locking bolts

1

Locking nuts

Rotatable tenon

STEP  1

:

 

3

Mains power 

supply cord

Cable gland

Rotatable tenon

Bubble level

STEP  3

:

 

4

5

Photocell

-20°

+20°

-20°

+20°

-+20

 

degrees adjustable

Screws to adjust and lock rotatable tenon

STEP 

4:

 

STEP 5:

 

 

WIRING

 I

NSTRU

CTIO

N

Terminal Block

LIVE

GROUND

NEGATIVE

LIVE 

-

 Black

NEGATIVE 

-

 White

GROUND-Housing

Mains power supply 

LE

D

 

DrivER

L

G

N

6

To adjust tilting angles from front to back, first loosen the screws on both 

 

sides of the rotatable tenon using 6mm hex wrench or its equivalent, see 

Figure 4.  

Secondly locate the tilt and adjust by tightening the mentioned screws at 

 

45 N.m.torque. To adjust the fixture from side to side, loosen the pole locking bolts,  see 

Figure 1

when ready, tighten the pole locking bolts at 45 N.m, then  tighten the pole locking nuts at 10 N.m 

torque so as to ensure the lighting fixture is installed to the pole firmly.

Installation Instruction & Installation Steps

Loosen nuts from pole locking bolts, then slide fixture on to pole through opening (tenon) on the 

rear of housing. See Figure 1.

Run main power supply cord into led driver compartment via cable gland, and use open spanner or 

similar tool to lock the gland to main power supply cord tightly. 

See Figure 3.

Slide fixture to the inner end of tenon, then tighten locking bolts 

 

with 5mm hex wrench or its equivalent to ensure the fixture is fixed to pole firmly. 

See Figure 1.

Loosen hinged hatch locking bolts with 5mm hex wrench or its equivalent, and open the hatch for 

led driver compartment access. 

See Figure 2.

STEP I:

 Connect the LIVE wire in the main power supply cord to the 

L marked hole In the terminal block , and tighten the connection 

properly.

STEP II:

 Connect the NEGATIVE wire in the main power supply cord to 

the N marked hole in the terminal block , and tighten the connection 

properly. 

STEP III:

 Connect the YELLOW/GREEN GROUNDING wire in the main 

power supply cord to the G marked hole in the terminal block , 

 

and tighten the connection properly.

Input wire H07RN-F 3x1.5mm² (SJOW 3 * 18AWG) or rubber sheathed 

cable (not supplied).Conductor must have a minimum cross-sectional 

area of 1.0mm² (18AWG).

This logo indicates that this product must not be disposed of with other 

waste.  Please recycle used lamps to prevent environmental hazard and 

threats to human health resulting from improper disposal.

STEP 6: 

 

Reference “Electrical Connections” section for completing electrical 

connections. 