6.2 SUPPORTED RDM PIDS

PID VALUE

RDM Parameter ID’s

0x0001

DISC_UNIQUE_BRANCH

0x0002

DISC_MUTE

0x0003

DISC_UN_MUTE

0x0020

QUEUED_MESSAGE

0x0030

STATUS_MESSAGES

0x0031

STATUS_ID_DESCRIPTION

0x0032

CLEAR_STATUS_ID

0x0050

SUPPORTED_PARAMETERS

0x0051

PARAMETER_DESCRIPTION

0x0060

DEVICE_INFO

0x0080

DEVICE_MODEL_DESCRIPTION

0x0081

MANUFACTURER_LABEL

0x0082

DEVICE_LABEL

0x0090

FACTORY_DEFAULTS

0x00C0

SOFTWARE_VERSION_LABEL

0x00E0

DMX_PERSONALITY

0x00E1

DMX_PERSONALITY_DESCRIPTION

0x0141

DMX_FAIL_MODE

0x0142

DMX_STARTUP_MODE

0x0200

SENSOR_DEFINITION

0x0201

SENSOR_VALUE

0x0501

DISPLAY_LEVEL

0x0641

LOCK_STATE

0x0642

LOCK_STATE_DESCRIPTION

0x0900

ENDPOINT_LIST

0x0901

ENDPOINT_LIST_CHANGE

0x0902

IDENTIFY_ENDPOINT

0x0903

ENDPOINT_TO_UNIVERSE

0x0904

ENDPOINT_MODE

0x0905

ENDPOINT_LABEL

0x0906

START_CODE_FILTER

0x0907

DISCOVERY_STATE

0x0909

ENDPOINT_TIMING

0x090A

ENDPOINT_TIMING_DESCRIPTION

0x090B

ENDPOINT_DEVICES

0x090C

ENDPOINT_DEVICE_LIST_CHANGE

0x090D

BINDING_CONTROL_FIELDS

0x1000

IDENTIFY_DEVICE

0x1010

POWERSTATE

0x1030

CAPTURE_PRESET

0x1041

PRESET_INFO

0x1042

PRESET_STATUS

0x9000

STORE_USER_PRESET

0x9001

RECOVER_BACKUP_MODE

0x9002

BACKUP_AUTORECOVER

0x9003

BACKUP_TIMEOUT

0x9004

STORE_SNAPSHOT

18

Содержание LumiSplit 1.6

Страница 1: ...USER MANUAL LUMISPLIT PRODUCT FAMILY LumiSplit 1 6 THANKS FOR CHOOSING LUMINEX Description User Manual LumiSplit 1 6 REVISION 20201020 REV 6 0 0...

Страница 2: ...2...

Страница 3: ...3...

Страница 4: ...ction 10 3 3 Modes in detail 10 3 4 Front Panel Lock 10 3 5 Factory Reset 10 4 THE NEW RDM EXPERIENCE 11 4 1 Discovery 11 4 2 Identify a LumiSplit 11 4 3 Lock Unlock the Front Panel 12 4 4 Dark Mode 1...

Страница 5: ...here the LumiSplit can be used Live events Concert lighting Theatre TV Installations Architectural lighting Multimedia shows Typical Application WELCOME TO YOUR LUMISPLIT 1 6 The LumiSplit range can b...

Страница 6: ...9 inch rack you must attach the included mounting ears Connect the longest ear A to the right hand side of the device with 4 screws re used from the device Attach the shorter ear B to the left hand si...

Страница 7: ...power cable on hand The device will automatically switch on To shut it down after use just un plug the power cable again After connecting the power cable correctly by default the power LED indicator o...

Страница 8: ...ltering on the input C INPUT LED Indicates the input status and the selected mode D OUTPUT LED Indicates the output status and the selected mode 2 3 2 Rear Panel E POWER 1x Neutrik powerCON TRUE1 inle...

Страница 9: ...ault or upgrading White Identify Orange Locked Front Panel Red Port error Red blink Factory Reset Blue DMX fail mode or Startup mode configured PORT LED STATUS DESCRIPTION Input Blue DMX RDM Cyan DMX...

Страница 10: ...iNet Monitor 3 3 1 Splitter mode The LumiSplit now runs in splitter mode This is the default mode 3 3 2 Regeneration The LumiSplit will re generate the incoming DMX signal with some new parameters The...

Страница 11: ...re v5 or higher are necessary to take full benefit of all the features listed below 4 1 Discovery The LumiSplit 1 6 comes with one RDM responder In the RDM panel one responder will appear per splitter...

Страница 12: ...ode The LumiSplit offers you to lower down the brightness of the LEDs Right click on one of the responders and select display level Here you can set the brightness either to low or full There is no in...

Страница 13: ...is connected to right click on the responder of the LumiSplit 1 6 and select Control In the control panel click on the endpoint tab If RDM devices are connected to the splitter they will appear on eac...

Страница 14: ...ng Identify check box and the LED of the selected port will blink white This can come in handy when you need to indicate the port to use 4 7 3 Regeneration When in regeneration mode click on the timin...

Страница 15: ...eneration mode default 36 FPS with a break time of 184 s Send snapshot makes it possible to send out the captured snap shot as lighting state with defined timings In this way the snap shot will be sen...

Страница 16: ...the minimum hold time is 0 1 second and the maximum is infinite 65535 or 0xffff When the hold time has elapsed the input zone of the LumiSplit will go back to Do nothing Or as soon the DMX signal has...

Страница 17: ...3 kg Operating temperature 0 to 50 C Storage temperature 10 to 70 C Humidity non condensing 5 to 95 Certificates Approvals cSGSus Mark CE CB certificate Standards IEC 60950 1 EN 60950 1 IEC 62368 1 EN...

Страница 18: ...142 DMX_STARTUP_MODE 0x0200 SENSOR_DEFINITION 0x0201 SENSOR_VALUE 0x0501 DISPLAY_LEVEL 0x0641 LOCK_STATE 0x0642 LOCK_STATE_DESCRIPTION 0x0900 ENDPOINT_LIST 0x0901 ENDPOINT_LIST_CHANGE 0x0902 IDENTIFY_...

Страница 19: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 19...

Страница 20: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: