8
U.L. Model No.: CF654
3. Ceiling Fan Assembly
(Continued)
BLADE
ASSEMBLY
M6 x 14 mm
FLANGE SCREWS
WITH LOCKWASHERS
Figure 10
3.10
NOTE: Remove and discard the five shipping
spacers and screws from the motor hub.
NOTE: Take care not to scratch fan housing when
installing blades.
Attach One Blade Assembly to the Motor Hub using
Two M6 x 14 mm Flange Screws with Lockwashers in
Flange .
Make sure the Screws are NOT tightened . (Figure 15) .
Repeat this procedure for the other Four Blade
Assemblies .
NOTE: The blade flanges have an interlocking
feature that must be fully engaged before
tightening the screws. Make sure all the flanges
are properly engaged and then tighten the flange
screws. If one of the flanges does not seat properly
on the motor hub, loosen the adjacent flange
screws, re-engage and reseat the flanges, then
tighten the screws again.
A spare M6 x 14 mm Flange Screw with Lockwasher is
supplied in parts bag, if needed .
3.9
Turn fan assembly upside down in preparation for
mounting fan blade assemblies .
IMPORTANT: THE SIDE OF THE FAN BLADE
HAVING THE RIB LINE MUST BE FACING
UPWARDS AS SHOWN IN FIGURE 9.
Mount the Blade Flange to the Fan Blade using
Three M5 x 6 mm Washer Head Screws (supplied)
(Figure 14) .
Repeat this procedure for other Four Fan Blades and
Blade Flanges .
A spare M5 x 6 mm Washer Head Screw is supplied in
parts bag, if needed .
FAN BLADE
BLADE FLANGE
M5 x 6 mm WASHER HEAD
BLADE SCREW (3)
Figure 9
To reduce the risk of personal injury, do not bend
the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.
WARNING
!
You have now completed the assembly of your new
Ceiling Fan . You can now proceed with hanging and
wiring your Fan .