INSTALLATION PROCEDURE 

 

1.

 

Remove Luminaire from carton and inspect for damage. 

2.

 

Remove End Caps. 

3.

 

Remove Lens via 8-32 screws. 

4.

 

Remove LED Board Assembly by loosening (2) ¼ hex screws. 

5.

 

Disconnect the LED Board Assembly from the Driver wires, set aside. 

6.

 

Mount Fixture to surface using (4) ¼ bolts (not included). 

7.

 

Connect all supply wires in accordance with national and local electrical codes. 

8.

 

Connect the LED Board Assembly to the Driver wires 

9.

 

Re-install LED Board Assembly using (2) ¼ hex screws.  Do not over tighten. 

10.

 

Re-install Lens. 

11.

 

Re-install End Caps. 

12.

 

Energize and test. 

13.

 

Adjust sensor sensitivity as required, see included Watt Stopper instructions.  