02001346 Rev 1
HPP-1000/6000 User Manual
Page 13 of 19
9.
HPP-6000 Specifications
Model
Average
Pout
Output Current
Input
Voltage
Size (L x W x H)
HPP-6000-XX-YY-ZZ
6000W
Up to 600A Pulse
150A CW
15 – 150VDC
12” x 8.1” x 3.5
Where XX = Iout
max
YY = Vcompliance
max
XX * YY* Duty Cycle cannot exceed 6000W
Auxiliary Outputs
: +15V @0.2A,
Input
Voltage
15-160 VDC current source, voltage limited
Output
Power
6000 Watts average
Pulsed Current
up to 600 A peak
Continuous Current
up to 150 A
Interface
Connector
15 Pin “D” Sub Female
Pulse Current Program
0-10V for 0-Max Current
Current Monitor
0-10V for 0-Max Current
Simmer Current Program
0-10V for 0-Max Current
Aux. Output
+15VDC @ 0.2A on interface
Performance
Max Rep Rate:
5 kHz
Rise/Fall Time:
~15 µs typical (10% to 90% Full Current)
Current Regulation:
0.5% of maximum output current
Current Ripple:
<0.5% of maximum output current
Current Overshoot:
<1% of maximum output current
Efficiency:
>90% at full load
Environment
Operating Temp
0 to 40
o
C
Storage
-40 to 85
o
C
Humidity
0 to 90% non-condensing
Cooling
Forced air
Altitude and Pressure
2000 meters maximum, 80 to 103 kPa
Dimensions
Please see Figure 7, HPP Mechanical Outline Drawing
Outline
13.8 inch length, 8.15 inch wide, 3.93 inch high
(does not include mounting flanges or electrical terminals)