background image

LF500-INS-LAB-RevC18

Read this manual before operating your Patient Lift.

Save this manual for future use.

LF500 PATIENT LIFT

USER MANUAL

Содержание LF500

Страница 1: ...LF500 INS LAB RevC18 Read this manual before operating your Patient Lift Save this manual for future use LF500 PATIENT LIFT USER MANUAL...

Страница 2: ...NS 8 6 USER GUIDE 10 CHARGING THE BATTERY 10 OPERATING INSTRUCTIONS USING THE CONTROL BOX 11 OPERATING INSTRUCTIONS USING THE HAND PENDANT 12 LIFT PREPARATION AND PROCEDURE 13 LIFTING THE PATIENT 13 E...

Страница 3: ...e several times with proper supervision and with a capable individual acting as patient It is extremely important to know how a patient will feel in the patient lift We suggest that the operator try a...

Страница 4: ...s NOTICE Indicates a potential hazard situation or unsafe practice that if not avoided could result in product or property damage Info Provides application recommendations or other useful information...

Страница 5: ...ushing on the mast boom actuator or patient Always maneuver the lift with the handle WARNING During lifting or lowering whenever possible always keep the patient lift legs in the maximum open position...

Страница 6: ...ring device Emergency button k Extra battery pack l Wall desk charging caddy a j i e f d c b h l k g CONTROL BOX COMPONENTS Control box on off and emergency stop button Control buttons LCD screen Batt...

Страница 7: ...dent notify the carrier or your GF authorized distributor 2 Remove all loose packing from the carton 3 Carefully remove all the components from the carton Info Unless the patient lift is to be used im...

Страница 8: ...as shown above 2 Plug the power base into the mast connector as shown above Ensure the connector is securely installed and inside the mast Install the mast in the base as shown above 3 Tighten the 3...

Страница 9: ...screws then attach the control box to the mast with the two screws then slide the battery in until it snaps into place as shown above Base leg actuator Lifting actuator Hand pendant 7 Insert the actua...

Страница 10: ...ttery will take 14 hours to fully recharge When the pendant shows 1 green flashing light battery will take 18 hours to fully recharge When the pendant shows 1 orange flashing light battery will take 2...

Страница 11: ...the button to open or the button to close the lift base legs Control Buttons Raise or lower the lift Adjust the distance between the lift legs Remaining battery capacity L Left button Pressing the lef...

Страница 12: ...ft while it is charging Raise Lower Lift Long press to raise lift Long press to lower lift 1 Press the button to raise or the button to lower the lift Open Close Base Legs Long press to close base leg...

Страница 13: ...closed position Preparation before lifting 1 Turn on the power 2 Ensure the battery is charged 3 Press the hand pendant UP or DOWN button once 4 Push the hand pendant UP button and DOWN button to ens...

Страница 14: ...open position 5 Hook the sling loops onto the spreader bar head loops followed by leg loops 6 If the patient is in an adjustable bed raise the bed s head section to elevate the patient 7 Carefully an...

Страница 15: ...chair movement could result which may result in serious injury to both the patient and the attendants 8 Position the patient over the wheelchair with their back against the back of the wheelchair 9 SL...

Страница 16: ...6 Hook the sling loops onto the spreader bar head loops followed by leg loops 7 If the patient is in an adjustable bed raise the bed s head section to elevate the patient 8 Carefully and slowly raise...

Страница 17: ...r The device consists of a plastic collar ring that should be pulled down then turned clockwise continually until the patient has been lowered Contact your dealer immediately if standard troubleshooti...

Страница 18: ...create a hazardous condition which may result in serious injury and will void the warranty WARNING The electronics and actuator contain no serviceable components DO NOT attempt to open the electronics...

Страница 19: ...inuing proper and safe operation Read and observe the following recommended maintenance schedule Item Inspect Inspect Adjust initially monthly every 3 months Boom spreader bar Check connections betwee...

Страница 20: ...replaced Overload Alarm Weight has exceeded the set maximum limit Remove weight from the lift and retry Force Interference If any force interferes when the lift is lowered the lift will stop working...

Страница 21: ...AINING WARRANTY SERVICE This limited warranty shall only apply to defects that are reported to the Distributor from whom the Customer purchased the product within the applicable warranty period If the...

Страница 22: ...OYEE OR INDEPENDENT CONTRACTOR WAGES PAYMENTS AND BENEFITS The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supers...

Страница 23: ...schedule 19 N NOTICE statement significance 4 O Operating instructions using the control box 11 Operating instructions using the hand pendant 12 P Preparation before lifting 13 R Removing the sling 1...

Страница 24: ...can be found on our website www grahamfield com 2016 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc One Graham Field Way Atlanta GA 30340 31...

Отзывы: