Lumax LX-1371 Скачать руководство пользователя страница 1

Electronic Flow Meter

Thank you for purchasing Lumax

®

 Electronic Flow Meter. Please read this Operational Manual carefully.  It is important that you read the 

entire manual to become familiar with the unit before you begin assembly and/or operate the unit. Lumax Electronic Flow Meter is ideal 

for metering the transfer of fluids. It is simple and easy to use. It can be installed in-line or at the end of the delivery hose before the nozzle. Using precision turbine measuring technology, Lumax 

Electronic Flow Meter measure liquids accurately and conveniently. Large 1” (25mm) LCD display can be calibrated in Gallons, Quarts, Pints and Liters. It has an easy-to-read five-digit LCD display 

for accurate readings while dispensing fluids, with a Totalizer (resettable) to track total usage. The display can be rotated at any angle which simplifies the reading in any position. Field replaceable 

batteries provide power and are easily accessible - simply loosen four screws on the back of the unit.

Technical Specifications:

•  Construction: Ryton

®

 Polyphenylene Sulfide (PPS) 

•  Connections Size: 1” NPT Inlet/Outlet 

•  Flow Range: 3-30 GPM (10L-120L/min)

•  LCD Display: Up to 5 digits 

•  Maximum Pressure: 300 PSI (20 Bar) 

•  Accuracy: ±1% 

•  Maximum Liquid Temperature: 140° (60°C) 

•  Single Count: 0.00-9999.99 

•  Working Voltage: 2.3-3.3V

•  Accumulative Count: 0.00-99999.9 

•  Standby Time: 2 years 

•   Measures in - Quarts - Pints - Liters - Gallons

WARNING: 

Please read instructions carefully before using the device. To ensure operator safety and to protect the device from potential damage, you must be fully acquainted with this instruction 

manual before performing any operation.  The Instructions contained in this Manual must be read and understood by the operator prior to operating the device. The meter installation work shall 

be performed in strict observance of the procedures and rules described in this manual. If instructions are not followed, it could result in malfunctions and damage to the device! Please store this 

Operational Manual, for later reference.

•   Do not expose the electronic meter to direct sunlight. Use Cover or Shield for outdoor installation.

•   The apparatus enclosure may contain aluminum and is considered to constitute a potential risk of ignition by impact or friction. Care must be taken into account during 

  installation and use to prevent impact or friction. 

•   Part of the enclosure is constructed from plastic. To prevent the risk of electrostatic sparking the plastic surface should only be cleaned with a damp cloth.

•   When metering flammable liquids, observe precautions against fire or explosion. Do not meter in the presence of any source of ignition including running or hot engines, 

  lighted cigarettes, or gas or electric heaters. 

•   If handling hazardous liquids, always follow the manufacturer’s safety precautions. Wear protective clothing such as goggles, gloves and respirators as instructed.

  Always dispose of used cleaning solvents in a safe manner according to the solvent manufacturer’s instructions.

•   During meter removal, liquid may spill. Follow the liquid manufacturer’s safety precautions to clean up minor spills. 

•   Do not blow compressed air through the meter. 

•   Do not submerge the meter.

•   Do not allow liquids to dry inside the meter. 

•   Do not use a wrench to install plastic meters. Hand tighten only.

WARNING: NOT APPROVED FOR USE IN EXPLOSIVE ATMOSPHERES OR HAZARDOUS LOCATIONS 

Wetted Components:

 

Ryton

®

 Polyphenylene Sulfide (PPS);  Stainless Steel (SS 316);  Viton

®

 (Fluoropolymer Elastomer);  Teflon

®

 (PTFE)

Materials (Can be Pumped): 

Anti Freeze (Alcohol & Glycol Base); Detergent Solutions; Fruit Juices; Salt Water; Sea Water (Brine); Soap Solutions; Urea/DEF/AdBlue; Vegetable Juices; Water: Fresh 

and Distilled (Deionized), 

Water-based Mild Chemicals, Low Viscosity Oil or Petroleum-based products such as Kerosene, Diesel, 

and Gasoline,

 Wines.

Warning:

 

Although Gasoline is oil based, it is Explosive & Extremely Dangerous to pump. Ground Wires are essential and required for Gasoline and Flammables

Warning:

 This product is not intended for potable water applications (human consumption – drinking and cooking) and has not been designed to be compliant with the “Safe Drinking Water Act” 

requirements for low lead in potable water applications. This item is for use only in non-potable (non-human consumption) water applications.

Materials (Cannot be Pumped):

 

Acetone, Ammonia, Bleach Solutions, Brake Fluid (Hexylene Glycol) Chlorine, Hydraulic Oil, Lacquers & Lacquer Solvents and Methanol

Caution: 

The above Materials List is to be referred for guidance only in selecting equipment for appropriate chemical compatibility. 

ALWAYS

 test your equipment under the specific conditions of your 

application before permanent installation. Ratings of chemical behavior listed in this manual apply at a 48 hour exposure period. Lumax has no knowledge of possible effects beyond this period. All 

recommendations are based on room temperature (72°F/22°C) exposure. Compatibility results may deviate from these recommendations at elevated temperatures. Recommendations are based on 

presence of listed chemical only.  Mixtures containing more than one chemical can greatly affect chemical compatibility.  Polypropylene products and components should not be used with low flash 

point chemicals, regardless of chemical compatibility results. Failure, improper selection, or improper use of the products referred to and described herein or related items can cause severe personal 

injury or property damage.  This document and other information provides product options for further investigation by users having technical expertise.  It is important that you analyze all aspects of 

your application and review the information concerning the product or system.

Due to the variety of operating conditions and applications for these products, the user, through his or her own analysis and testing, is solely responsible for making the final selection of the products 

and assuring that all performance, safety and warning requirements are met.  The materials described and referred to herein are subject to change at any time without notice. Lumax does not warrant 

(neither express nor implied) that the information in this chart is accurate or complete or that any material is suitable for any purpose. If there is any question about any Material that can or cannot be 

pumped, do not operate the device.  Check with Lumax as to whether it is safe or unsafe, to operate the device.

Caution: Always 

check local area Laws and Ordinances regarding Handling, Pumping and Disposing of Liquids.  Dispose of pumped fluid properly. 

Do Not 

drain into Street Drains, House Drains, or 

Backyards. Contact your local Municipal Waste Management officials for proper disposal methods. 

If there is any question about a condition being safe or unsafe, do not operate the meter.

Before Installation: 

Upon receipt, examine your meter for visible damage. If the item is damaged, contact your distributor. Make sure the meter model meets your specific needs. Refer to the 

Specifications Section and confirm the following:

1.

   The flow-rate is within the limits of your model. 

2.

  The

 liquid is compatible with your meter’s material.

3.

  The

 system’s pressure does not exceed the meter’s maximum pressure rating.

Connections:  1.

  To protect against leakage, make sure all threads are sealed with two or three turns of thread tape or a sealing compound compatible with the liquid being metered. 

  

 

Caution:

 Make sure the thread tape or sealing compound does not interfere with flow.

  

2.

  Make sure the arrow on the outlet is pointing in the direction of the flow. 

3.

  Tighten the meter onto the fittings. Hand tighten. Using a wrench could damage the meter.

Display Positioning:

 Square shape housing allows 

the 

LCD Display

 to be rotated 

in any position for easy display readings. The LCD Display Card is easily accessible, by removing the faceplate cover 

and unscrewing the four screws. The LCD Display can be rotated in any direction to suit the piping system. 

Caution: 

Make sure you remove the LCD Display Card very slowly and 

carefully to ensure that any damage to the Wires, Connections, 

or the LCD Display Card is avoided.

Operating Modes:

 Choose between two modes of operation:

- Normal Mode: Display of Partial and TOTAL

 amount dispensed

- Flow Rate Mode: Display of Flow Rate and Partial dispensed quantities

The meter features a non-volatile memory, for storing the dispensing data 

for longer periods in the case of power outage.

The electronic measurements are displayed in the upper part of 

the LCD Display. They are isolated from the liquid measuring Chamber.

LCD Display:

 The LCD Display of the Lumax Electronic Flow Meters features two numerical registers and several function or status indicators:

Key:
1.

   Partial Register (5 digit from 0.1 to 9999.9) indicating the volume dispensed since the reset button was last pressed. For Partial RESET - Press “RESET” Button for 1 Second

2.

  Battery Charge Indicator

3.

  Calibration Mode Indicator

LX-1371

RESET

MENU

RESET

MENU

RESET

MENU

RESET

MENU

Отзывы: